GET THE APP

Investigating long-term stability of sulfur and fluorine based adlayers on stainless steel stent models
..

Journal of Molecular Biomarkers & Diagnosis

ISSN: 2155-9929

Open Access

Investigating long-term stability of sulfur and fluorine based adlayers on stainless steel stent models


6th International Conference on Biomarkers & Clinical Research

August 31-September 02, 2015 Toronto, Canada

Rohan R Ravindranath1, 2, Alexander D Romaschin1 and Michael Thompson2

1St. Michaelâ??s Hospital, Canada 2University Of Toronto, Canada

Posters-Accepted Abstracts: J Mol Biomark Diagn

Abstract :

Nanomedicine continues to be an emerging discipline, providing novel solutions to diseases that otherwise could not be treated effectively. The development and use of self-assembled monolayers and adlayers for biomedical applications has allowed bioincompatible materials such as stainless steel and cobalt-chromium, to be used as effective medical devices. In terms of stainless steel, this material has been widely used to develop stent implants. Stents are expandable tubes used to open up a restricted artery. Conventional implantation of a bare metal stent can cause renarrowing of the artery over time restenosis, due to an immune response launched by the body towards the â??foreignâ? stent. As a result, improving the biocompatibility of stainless steel is thought to be critical for creating a stent that is not rejected by the body. Benzothiosulfonate (BTS) and Pentafluorophenyl Ester (PFP) are two chemical molecules that have previously been used as surface modifiers of stainless steel and quartz. BTS was recently used as a surface coating on stainless steel to bind antibodies, which could then in principle be used to bind specific biomarkers on circulating endothelial cells. For this stent application, it is important that the surface coatings show minimal chemical change over time, when placed in a physiological environment. This investigation involved assessing the long-term stability of BTS and PFP coatings on stainless steel. Surface characterization techniques like X-ray photoelectron spectroscopy, contact angle goniometry and atomic force microscopy were used to analyze the integrity and composition of the adlayers upon immersion in physiological buffer solution.

Biography :

Rohan R Ravindranath completed his BSc (Hons) from the University of Toronto in Chemistry and Biotechnology. Currently, he is pursuing his MSc in Chemistry under the joint guidance of Professor Michael Thompson and Professor Alexander Romaschin at the University of Toronto and at St. Michael’s hospital. He has presented his past research at various local conferences and has been awarded a best poster prize.

Email: rohan.ravindranath@mail.utoronto.ca

Google Scholar citation report
Citations: 2054

Journal of Molecular Biomarkers & Diagnosis received 2054 citations as per Google Scholar report

Journal of Molecular Biomarkers & Diagnosis peer review process verified at publons

Indexed In

 
arrow_upward arrow_upward