GET THE APP

Investigation of wear in orthopaedic hip prosthetic devices
..

Journal of Bioengineering & Biomedical Science

ISSN: 2155-9538

Open Access

Investigation of wear in orthopaedic hip prosthetic devices


2nd Biomedical Engineering Conference and Expo

November 30-December 01, 2015 San Antonio, USA

Obinna K Ihesiulor1, Krishna Shankar1, Paul Smith2,3 and Alan Fien1

1University of New South Wales, Australia 2Canberra Hospital, Australia 3Australian National University, Australia

Scientific Tracks Abstracts: J Bioengineer & Biomedical Sci

Abstract :

Total hip replacement (THR) is one of the most popularly performed operations in orthopaedics as evident in clinical outcomes. Potentially, an approximate of 400,000 hip joint replacement procedures are performed each year in the US. However, studies have identified that majority of hip implants are prone to wear at the taper-trunnion junction. The tapertrunnion (head-stem) is essentially the interface between the ball of the hip joint which articulates with the pelvis and the hip stem which is constrained rigidly to the femur bone. The head and stem components connect at a taper on the hip head and a trunnion on the hip stem. This junction is of peculiar and remarkable interest because it is associated with excessive fretting wear due to the taper sliding relatively against the trunnion. Excessive fretting wear at the taper-trunnion junction (trunnionosis) apparently contributes to the high failure rates of hip implants. Implant wear and corrosion lead to the release of metal particulate debris and subsequent release of metal ions at the taper-trunnion surface. This results in a type of metal poisoning referred to as metallosis. The consequences of metal poisoning include osteolysis (bone loss), osteoarthritis (pain), aseptic loosening of the prosthesis and revision surgery. Follow up after revision surgery, metal debris particles are commonly found in numerous locations. The aim is to investigate the feasibility of reducing wear in taper/head-trunnion/stem (headstem) joints in hip implants by the use of cylindrical/parallel head-stem joints instead of the currently used tapered stems.

Biography :

Obinna K Ihesiulor is presently a PhD student at the University of New South Wales, Canberra, Australia. He obtained his Master’s degree in 2012 at the same University. His current research interest is in the area of prosthetic devices for joint replacements. His PhD research work is on the investigation of wear of total hip replacement at the taper-trunnion junction. In a broader sense, the principal goal is to work toward the minimization of wear debris produced in the hip joint, thereby resulting in a longer prosthetic lifetime.

Email: o.ihesiulor@adfa.edu.au

Google Scholar citation report
Citations: 307

Journal of Bioengineering & Biomedical Science received 307 citations as per Google Scholar report

Journal of Bioengineering & Biomedical Science peer review process verified at publons

Indexed In

 
arrow_upward arrow_upward