Figure 2: (A) Frontal view of the stereolithrography model with the pre-adapted plates in place. A titanium mesh was also pre-contoured and adapted to match the anatomy of the orbital floor and used to reconstruct the inferior orbital wall. (B) Frontal view showing the defect, reconstructed using free micro vascular grafts, with the pre-adapted reconstructive plates in place (C) Preoperative MRI showing a homogenous mass occupying the left maxilla and sinus and extends to affect the orbital floor and base of the skull. (D) Postoperative, three dimensional formatted image displaying the defect after the resection of the tumour. The pre-adapted reconstructive surgical plates together with the titanium mesh bridged the defect, produced the exact contour of the maxilla and maintained skeletal symmetry. |