Make the best use of Scientific Research and information from our 700+ peer reviewed, Open Access Journals that operates with the help of 50,000+ Editorial Board Members and esteemed reviewers and 1000+ Scientific associations in Medical, Clinical, Pharmaceutical, Engineering, Technology and Management Fields.
Meet Inspiring Speakers and Experts at our 3000+ Global Conferenceseries Events with over 600+ Conferences, 1200+ Symposiums and 1200+ Workshops on Medical, Pharma, Engineering, Science, Technology and Business

A Rapid and Sensitive LC-MS/MS Assay for the Quantitation of Bromantane in Human Plasma

Igor I Miroshnichenko, Svetlana A Sergeeva, Angelina I Platova* and Lyudmila M Krasnykh

Mental Health Research Center of RAMS, Moscow, Russia

*Corresponding Author:
Angelina I Platova
Mental Health Research Center of RAMS
Moscow, Russia
E-mail: [email protected]

Received Date: January 20, 2013; Accepted Date: February 21, 2013; Published Date: February 25, 2013

Citation: Miroshnichenko II, Sergeeva SA, Platova AI, Krasnykh LM (2013) A Rapid and Sensitive LC–MS/MS Assay for the Quantitation of Bromantane in Human Plasma. J Sports Med Doping Stud 3:120. doi:10.4172/2161-0673.1000120

Copyright: © 2013 Miroshnichenko II, et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

Visit for more related articles at Journal of Sports Medicine & Doping Studies

Abstract

The purpose of this study was to develop and validate a high-performance liquid chromatographic–tandem mass spectrometric (LC–MS/MS) method for analysis of the bromantane in human plasma. The analyte and Internal Standard (IS), selenox, were extracted from human plasma by solid-phase extraction and separated on a Zorbax SB-C18 column using methanol–0.2% formic acid as mobile phase. Detection was performed using an atmospheric pressure chemical ionization source and mass spectrometric positive Multi-Reaction-Monitoring-Mode (+MRM) at an ion voltage of +2000 V. The assay was linear over the concentration range 1–500 ng/mL with the Lowest Limit of Quantification (LLOQ) of 1 ng/mL. The method also afforded satisfactory results in terms of the sensitivity, specificity, precision (intra- and inter-day, CV<10%), accuracy, recovery as well as the stability of the analyte under various conditions. The method can be applied to pharmacokinetic and toxicological studies.

Keywords

Bromantane; Liquid Chromatography–Mass Spectrometry (LC–MS/MS); APCI; Plasma

Introduction

Bromantane, N-(4-bromophenyl) adamantan-2-amine, is a drug with anxiolytic and immunostimulatory actions and elements of actoprotective activity [1-3]. Bromantane is not potentially addictive and does not exert effects of hypnosedation or neuromuscular relaxation. The use of the drug, in contrast to the action of a typical psycho stimulant, is not associated with the phenomenon of hyper stimulation and causes no consequences such as functional exhaustion of the body [4]. These properties of drug stipulated its using as a doping agent [5]. According to World Anti-Doping Agency classification, Bromantane belongs to S6; a class of prohibited substances [6].

The therapeutic action of Bromantane in patients with asthenic and anxiety-asthenic disorders is exhibited from first day of application, which is expressed by a marked reduction of asthenic symptoms, signs of emotional tension, and somatoautonomic manifestations; the drug works by restoring performance and enhancing the endurance of the body. Its mechanism of action is associated with the release of reinforcing dopamine from the presynaptic terminal [7], blockade of its reuptake, and enhancement of biosynthesis and induced tyrosine hydroxylase gene expression, as well as with a modulatory effect on the Benzodiazepine-GABA-receptor-chloride ion channel complex, upregulating the stress-induced decrease of benzodiazepine reception. Bromantane increases GABAergic transmission, reduces gene expression, and regulates the synthesis of GABA-mediators, which act as reuptake transmitters. Bromantane has low toxicity (LD50 in rats is higher than 10000 mg/kg, exceeding the effective dose by 100 times).

Appropriate analytical method is an urgent need to study bromantane pharmacokinetic properties. The gas chromatography approach for content determination has been applied to a pharmacokinetic study of Bromantane [8]. However, this method was not quite appropriate for clinic pharmacokinetic studies of bromantane. LC/MS spectrometry based techniques are now the mainstay for such pharmacokinetic studies because of sensitivity, selectivity, speed and cost effectiveness [9]. Recently some papers devoted LC-MS/MS method for the quantitative estimation of amantadine (1-adamantylamine) [10] and memantine appeared in press [11,12].

The most commonly used sample preparation methods for blood plasma samples are Liquid–Liquid Extraction (LLE) and Solid-Phase Extraction (SPE). SPE is growing in use, and it offers certain advantages over LLE, including better specificity, the ability to obtain cleaner samples, good reproducibility, and a substantial reduction in the volume of solvent required [13].

However, we do not find HPLC–MS/MS methods reported in the literature for quantification of bromantane in biological samples. This paper reports on a rapid and sensitive LC–MS/MS method for the determination of bromantane in human plasma using SOLA cartridges. The method employs using 9-phenyl-sym-octahydroselenoxanthene (selenox) as internal standard and is completed in a run time of 6 min.

Experimental

Chemicals and reagents

Bromantane was kindly supplied by the Pharmacology Institute of RAMS, Moscow, 9-phenyl-sym-octahydroselenoxanthene synthesized by “Medbiopharm”, Obninsk, and Kaluga region. Formic acid (Sigma Inc., USA), methanol and acetonitrile (Lab-Scan, Poland) were HPLCgrade. Deionized water was prepared from distilled water using Simplicity UV System (Millipore, USA). All other chemicals and solvents were analytical grade and used as received. The SOLA reversed phase extraction cartridges were purchased from Thermo Fisher Scientific Inc. (USA).

LC–MS/MS conditions

The HPLC–MS/MS system consisted of an Agilent 1200 series binary pump, an auto sampler connected to Agilent 6410-2K Triple Quad LC-MS (Agilent Technologies, Palo Alto, CA, USA) using a atmospheric pressure chemical ionization (APCI). The instrument was interfaced to a computer running Agilent Mass Hunter B.01.04. Software.

Bromantane and IS were separated a Zorbax SB-C18 column (3.5 μm, 100 mm × 4.6 mm I.D., Agilent, USA) through a 12.5 mm × 4.6 mm Zorbax SB-C18 precolumn maintained 20°C. The mobile phase consisted of methanol–0.2% formic acid (95:5, v/v). The flow rate throughout the chromatographic analysis was 0.8 mL/min, and the total run time was 6 minutes. The injection volume was 5 μL. The retention times were 3.2 min for bromantane and 5.1 min for IS.

The detector was operated at unit resolution in the positive Multiple-Reaction Monitoring-Mode (+MRM) mode using the transitions of the protonated molecular ions of bromantane (308.1 → 135.2 m/z), IS (331.0 → 250.0 m/z). MS parameters were optimized by syringe pump infusing of standard solution containing analyte and IS. The spray voltage was set at 2000 V. Corona discharge was 4 μA. Nitrogen was used as nebulizer gas and pressure was set at 20 psi. Desolvation gas (nitrogen) was heated to 350°C and delivered at a flow rate of 5 L/min. For Collision-Induced Dissociation (CID), high purity nitrogen was used at a pressure of 0.15 MPa. During the data acquisition, dwell time was 200 ms. The fragmentation energy of Q1 and collision energy were 135 V and 25 V (bromantane), 90 V and 5 V (IS), respectively.

Preparation of calibration standards and quality control samples

A stock solution of bromantane was prepared in methanol at a concentration of 1.0 mg/mL. Standard solutions (10, 25, 50, 100, 500, 1000, 5000 ng/mL) were prepared by serial dilution of the stock solution with methanol. Low, medium and high concentration Quality Control (QC) solutions (4, 45, 125 ng/mL) were prepared in the similar way. The stock solution of I.S. (1.0 mg/mL) was also prepared in methanol and then diluted with methanol to a final concentration of 10 μg/mL. All solutions were stored at 4°C and used within one month after preparation. Calibration standards and QC samples were prepared by adding 50 μL standard and 50 μL IS or QC solution to 500 μL blank human plasma.

Sample preparation

A sample (500 μL) of human plasma was transferred to a 5.0 mL glass tube, 50 μL methanol or 50 μL standard of bromantane and 50 μL IS solutions were added. If needed (sample not transparent), the mixture was ultra-sonicated. SPE was conducted by using SOLA RP extraction cartridges. The cartridges were conditioned sequentially with 500 μL of ethanol and with 500 μL of water, and 500 μL of plasma sample diluted equal volume of water was then loaded. The loaded cartridges were washed with 500 μL 5% ethanol in water, and subsequently the analyte was eluted with ethanol. The elution was then evaporated to dryness under N2 stream at 50°C, reconstituted with 200 μL of methanol, and vortex mixed for 10 s. Finally, the solution was transferred to the autosampler vials, and 5 μL was injected into HPLC/MS/MS system.

Method validation

The method validation assays were carried out according to the currently accepted US Food and Drug Administration (FDA) bioanalytical method validation guidance [14].

The method’s specificity was tested by screening six different batches of healthy human blank plasma. Each blank sample was tested for interference using the proposed extraction procedure and chromatographic/spectroscopic conditions and compared with those obtained with an aqueous solution of the analyte at a concentration near to the LLOQ.

The matrix effect on the ionization of analytes was evaluated by comparing the peak area of analytes resolved in blank sample (the final solution of blank plasma after extraction and reconstitution) with that resolved in mobile phase.

Three different concentration levels of bromantane (4, 45 and 125 ng/mL) were evaluated by analyzing five samples at each level. The blank plasma used in this study was five different batches of healthy human blank plasma. If the ratio <85 or >115%, an exogenous matrix effect was implied.

For the calibration standards, peak area ratios (the analyte/IS) were plotted against nominal plasma concentrations, and fitted by weighted (1/y2) least-squares linear regression. Plasma calibration curves were prepared and assayed in triplicate on three separate days. In addition, blank plasma was also analyzed to confirm absence of interferences.

The intra-day precision and accuracy of the assay was measured by analyzing five spiked samples of bromantane at each QC level (4, 45 and 125 ng/mL). The inter-day precision and accuracy was determined over three consecutive days by analyzing 15 QC samples. The acceptance criteria for precision and accuracy deviation values should be within 15% of the actual values. The extraction yield (or absolute recovery) was determined by comparing the bromantane/IS peak area ratios obtained following the outlined extraction procedure (the procedure was a little different from the outlined extraction procedure for QC, calibration curve and clinical plasma samples, that is IS was added to the organic layer after the extraction of bromantane) and the result compared with those obtained from samples which contained the same amount of bromantane in extracted plasma but not be extracted after addition of the drug. This procedure was repeated for the three different concentrations of bromantane added, namely 4, 45 and 125 ng/mL.

For sensitivity determination, the LLOQ was defined as the lowest concentration in the calibration curve at which both precision and accuracy were less than or equal to 20%, and signal/noise (S/N) >10. The 1 ng/mL concentration was investigated as the lower limit of quantification. Reproducibility and precision were also determined.

To evaluate stability on repeat analysis of samples, freeze-thaw stability was determined for three concentrations of bromantane in plasma. QC plasma samples were tested after three freeze (−20°C) and thaw (room temperature) cycles.

Results and Discussion

LC/MS/MS conditions

Certain classes of compounds are traditionally very difficult to ionize or tend to show low sensitivity in LC/MS/MS techniques. Although electrospray ionization is often used as an LC-MS interface, APCI, another type of atmospheric pressure ionization, is more applicable to low polarity compounds [15]. In APCI, the corona discharge can provide a source of electrons in the gas-phase. This can be an advantage for such non polar compounds as adamantanes.

The LC–MS/MS operation parameters for determination of bromantane and IS were carefully optimized. Selenox was selected as the IS because its chromatographic behavior and extraction efficiency were similar to those of analyte. Both analyte and IS responded best to the positive ionization mode, with the protonated molecular ions [M+H]+ as the major species. Full scan ion spectrum of Bromantane was shown in figure 1. The MRM acquisitions were performed at unit resolution using the transition 308.1 → 135.2 m/z for bromantane and 331.0 → 250.0 m/z for IS respectively (Figure 2). The transition 308.1 → 135.2 m/z was used for quantification of bromantane because of its stabilized ions response and no endogenous interference. The mass parameters were optimized by observing the maximum response obtained for the product ions. The intensities of its protonated molecules were compared at fragmentor voltages of 90, 100, 120, 130, 135, 140 and 150 V in order to determine the optimal collision energy. The results showed that the highest sensitivities could be obtained by using a 135 V fragmentor voltage.

sports-medicine-doping-studies-scan-turboIonspray-spectrum

Figure 1: Full scan positive ion turboIonspray Q1 mass spectrum of Bromantane.

sports-medicine-doping-studies-spectrum-parent-bromantane

Figure 2: MS/MS spectrum of the m/z = 308.1 parent ion, exhibiting the product ions of Bromantane at m/z =135.2.

Furthermore, the mobile phase system was optimized through several trials to achieve satisfactory chromatographic behavior and the ionization responses of bromantane and IS. The ionization of bromantane and IS was affected by the composition of mobile phase. In the preliminary experiments, methanol, acetonitrile, ammonium acetate and formic acid in various proportions were tested. Methanol, rather than acetonitrile, was chosen as the organic modifier because it leads to the good peak shape of bromantane and satisfactory retention time. When ammonium acetate was added in the mobile phase, the response of the analyte was distinctly decreased. Both the analyte and IS were found to have higher response and better peak shapes in the mobile phase containing 0.5% formic acid. Finally, in terms of peak shape, retention time and sensitivity, we employed methanol –0.5% formic acid (95:5, v/v), as the mobile phase.

Assay validation

The linearity for bromantane was investigated by linear regression of peak area ratios against concentrations (Figure 3). The regression equation for the calibration plot was y=0.081+0.0255*x, with a coefficient of correlation (r) of 0.995 (where y – the ratio of the peak areas of bromantane to the peak area of the internal standard; x – bromantane concentration, ng/mL). The calibration curves of bromantane showed good linearity in the ranges of 1–500 ng/mL (Table 1). LLOQ for bromantane in plasma was proved to be 1 ng/mL (S/N=9.5) (Figure 4).

sports-medicine-doping-studies-bromantane-human-plasma

Figure 3: Regression line for the determination of Bromantane in human plasma.

sports-medicine-doping-studies-mass-chromatograms-bromantane

Figure 4: MRM mass chromatograms of LLOQ (1 ng/mL) of Bromantane.

Spike Conc. RT Final Conc. Accuracy Area S/N Area IS
1 3.21 1.02 102.3 661 9.5 19337
2.5 3.22 2.53 101.4 1321 16.0 18147
5 3.22 4.67 93.4 2305 26.7 18105
10 3.22 9.63 96.3 3841 16.3 15123
50 3.22 47.52 95.0 19068 82.6 15611
100 3.22 109.02 109.0 44764 143.2 16035
500 3.22 533.34 106.7 246547 209.4 18096

Table 1: The linearity of Bromantane determination.

Our investigations have confirmed the fact of negligible matrix effects coupled to APCI [16]: the ratios of the peak responses for bromantane were 99.0%, 98.9%, and 100.3% at 4, 45 and 135 ng/mL, respectively (Figure 5). The results indicated that co-eluting endogenous substances hardly inhibited the ionization of bromantane, and the ion suppression from human plasma matrix was consistent for this analytical method and would not interfere with the measurement of analyte. Thus, no ion suppression was observed.

sports-medicine-doping-studies-chromatograms-plasma-bromantane

Figure 5: Typical mass chromatograms of plasma spiked with Bromantane (45 ng/mL) and the IS (1 μg/mL), validation of Bromantane Quantitation.

The extraction recovery determined for bromantane was shown to be consistent, precise and reproducible. The absolute recoveries of bromantane from the rat plasma at the three concentrations were about 89%. There was no significant difference in the extraction efficacy of the present assay over the range of concentrations studied.

The intra-day and inter-day precision (CV, n = 5) for bromantane were satisfactory at the three concentrations studied. Data on precision, accuracy are shown in table 2. The results of freeze–thaw stability indicated that the analyte is stable in plasma for three freeze–thaw cycles, when stored at−20°C and thawed to room temperature. Long-term stability indicates that storage of bromantane plasma samples at −20°C is adequate when stored for 30 days and no stability related problems would be expected during routine analysis for the pharmacokinetic or abuse control studies.

Calculated C (ng/ml) Found C (ng/ml) Intra-day precision R.S.D. (%) Inter-day precision R.S.D. (%) Accuracy RE (%)
4 4.26 7.5 8.6 6.5
45 44.26 9.4 8.9 -1.6
135 138 5.1 7.3 1.9

Table 2: Accuracy and precision of the assay for determination of Bromantane in plasma (n=5).

Conclusion

The proposed method of analysis provided a sensitive and specific assay for bromantane determination in human plasma. No significant interference caused by endogenous compounds was observed. The method was rapid, selective and highly sensitive with a LLOQ of 1 ng/mL for bromantane. Simple liquid–liquid extraction procedure and short run time can provide a short analysis time that is important for large sample batches. The developed method was completely validated showing satisfactory data for all the method validation parameters tested. It was shown that this method is suitable for the analysis of bromantane in plasma samples collected for pharmacokinetic, bioavailability, bioequivalence studies or doping control.

Acknowledgements

The authors are thankful to prof. N.N. Zolotov from the Institute of Pharmacology Russian Academy of Medical Sciences for providing sample of Bromantane for the research work.