Previous Page  22 / 24 Next Page
Information
Show Menu
Previous Page 22 / 24 Next Page
Page Background

Page 64

Journal of Pharmaceutical care and Health Systems | ISSN: 2376-0419 | Volume 5

Pharmaceutical sciences

11

th

World Congress on

September 28-29, 2018 | Montreal, Canada

The effect of antioxidant and filler type on Diltiazem hydrochloride sustained release tablet matrices

containing Polyethylene oxide

Saeed Shojaee, Faezeh Majzoubi

and

Ali Nokhodchi

School of Life and Science, UK

Introduction:

Polyethylene oxide (PEO) is one of the hydrophilic polymers that have been extensively used to prepare sustained

and modified release dosage forms. The objective of this study is to investigate the effect of vitamin E succinate and different fillers

(mannitol and DCP) on release rate stability of highly soluble drug Diltiazem HCl containing Polyethylene Oxides.

Experimental Methods:

Diltiazem hydrochloride was obtained from Elan Drug Technologies. PEO grade 303, Vitamin E, Mannitol

and dicalcium phosphate dehydrate were obtained from Merck, Germany. Diltiazem HCl: PEO with a ratio of (1:1) was prepared

and Matrix tablets with target weights of 240 mg for pure samples, 242.4 tablets containing Vit E and 300 mg for filler tablets were

prepared by the compression of the above mixtures at 1500 psi. In order to investigate the effect of different filler types DiltiazemHCl:

PEO: filler with a ratio of (1:1: 0.5) was prepared and mixed.Then the mixture was compressed at the same conditions as described

above. Drug release was determined by dissolution testing for these tablets. Dissolution testing was performed for the non-aged

polymer as the control. These were considered as zero (0) week. The USP paddle method (Erweka, Germany) was used to monitor

the dissolution profiles of Diltiazem HCl. The dissolution medium was 900 ml distillate water equilibrated to 37ºC + 0.1ºC and the

paddles were rotated at 100 rpm. The viscosity of samples also was done using the Dr. Schleuniger® Pharmatron.

Results And Discussion:

The effect of storage conditions showed that the release rate of the drug was significantly increased from

tablets that were stored for longer periods at 40

o

C. That is to say, drug release was faster at longer storage times (8 > 4 > 2 > 0 weeks).

The increase in drug release is expected to be due to oxidative degradation Primarily in the amorphous region of the polymers. The

results also showed that there was a significant decrease in the drug release rate of the formulations that contained all concentrations

of Vit E used (1% w/w). In other words, the use of Vit E PEO decreased the rapid drug release occurring as a result of the storage time

(2, 4, 8 weeks) at 40

o

C. The reason behind this phenomenon could be when Vit E was dispersed in the PEO containing drug, it delayed

the penetration of oxygen (O2) into the PEO matrix during the storage time. These results confirmed by viscosity data. As it can be

seen from the viscosity of the polyox samples containing Vit E is higher than the same samples without Vit E. there was a significant

decrease in the drug release rate of the formulations contained mannitol and dicalcium phosphate (DCP). This can be attributed to

an increase in the viscosity of the gel layer and also they are able to form a complex with a cationic drug.

Conclusion:

PEO can successfully be used in controlled release drug delivery to modulate the drug release. The presence of Vit E is

necessary to stabilize the drug release from matrices containing PEO. Mannitol or DCP can also stabilize the drug release from PEO

matrices in absence of Vit E.

J Pharma Care Health Sys 2018, Volume 5

DOI: 10.4172/2376-0419-C3-033