Make the best use of Scientific Research and information from our 700+ peer reviewed, Open Access Journals that operates with the help of 50,000+ Editorial Board Members and esteemed reviewers and 1000+ Scientific associations in Medical, Clinical, Pharmaceutical, Engineering, Technology and Management Fields.
Meet Inspiring Speakers and Experts at our 3000+ Global Conferenceseries Events with over 600+ Conferences, 1200+ Symposiums and 1200+ Workshops on Medical, Pharma, Engineering, Science, Technology and Business

Disinfection of Wastewater by Infiltration-Percolation Coupled to UV Irradiation in an Arid Tunisian Area

Brahmi Mounaouer*, Fourti Olfa and Hassen Abdennaceur
Water Research and Technology Centre, Borj Cédria Science and Technology Park, Tunisia, University Tunis Cartage, Tunisia
Corresponding Author : Brahmi Mounaouer
Water Research and Technology Centre
Borj Cédria Science and Technology Park
Tunisia, University Tunis Cartage, Tunisia
Tel/Fax: +21679 325 802
E-mail: [email protected]
Received July 12, 2013; Accepted August 08, 2013; Published August 14, 2013
Citation: Mounaouer B, Olfa F, Abdennaceur H (2013) Disinfection of Wastewater by Infiltration-Percolation Coupled to UV Irradiation in an Arid Tunisian Area. Hydrol Current Res 4:155. doi: 10.4172/2157-7587.1000155
Copyright: © 2013 Mounaouer B, et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
Related article at
DownloadPubmed DownloadScholar Google

Visit for more related articles at Hydrology: Current Research

Abstract

This paper aimed to the study of microbiological quality of wastewater effluents issued from a sand filter system used as a secondary treatment; this sand filter was coupled to UV irradiation system as a tertiary treatment to assume their possible application as alternatives to chemical disinfection of municipal wastewater before agronomic utilization. For that reason, an infiltration basin of 100 m² of area equipped with two wells of sampling, in the center and in the periphery, has been constructed on the irrigated perimeter of Dissa in Gabes (south east of Tunisia). A comparative study was undertaken concerning the quality of effluents obtained from the sand filter as secondary effluent and from the UV irradiation disinfection system as a tertiary municipal wastewater treatment. Both the combined systems gave effluent of excellent microbiological quality (almost total absence of E. coli, faecal coliforms and P. aeruginosa). However, if the microbiological quality of effluent remained constant in the case of a sand filter system which depends only on the quality of the influent, while with the UV-disinfection process, microbiological quality of tertiary effluent was shown to depend on the quality of secondary effluent. The monitoring of the UV irradiation device using a UV dose of around 96 mW.s.cm-2 and corresponding to an exposure time of 16 sec, for the secondary effluent at the outlet of Sand Filter, showed that the average bacterial inactivation rate was around 3 U-Log for E. coli, faecal coliforms and P. aeruginosa, respectively. Therefore, the average concentration remaining in the effluent at the output of the UV reactor, was less than a 100 cfu/ 100 ml for E. coli and faecal coliforms, and less than a 100 bacteria/ 100 ml for P. aeruginosa. These values coincided with the range recommended by several standardized international guidelines.

Keywords
Disinfection; Infiltration-percolation; Sand filter; UV reactor; Wastewater
Introduction
Reclamation and reuse of municipal wastewater have increased in recent years, largely due to lack of water resources and inadequate economic structures, particularly in arid and semi-arid countries [1]. However, the contamination of wastewater by pathogenic microorganisms represents a significant risk to public health. Poor water quality can cause illnesses such as gastroenteritis or upper respiratory infections, etc. Highly polluted water can occasionally cause serious diseases such as typhoid fever, dysentery, hepatitis, and cholera (USEPA) [2]. In this sense, to reduce this inconvenient, treated wastewater reuse must meet the microbiological and physicochemical standards recommended by international authorities to avoid damaging public health and the environment [1].
The use of treated wastewater is considered as an important alternative water resource. Although conventional treatment processes, i.e. primary treatment, disc filter and pressure sand filter are known to remove up to 99% of microorganisms that it is not sufficient to achieve requirements for wastewater discharge and wastewater reuse [3]. So, the disinfection is considered to be the primary operation of the inactivation or the destruction of pathogenic organisms and to prevent the spread of waterborne disease. On the other hand, the water disinfection efficiency depends on several factors: particularly an adequate contact time to ensure a sufficient decrease of microbial pathogens and a good water quality, the UV transmittance [4].
To date, chlorination is the most widely used procedure to inactivate pathogenic micro-organisms in water and wastewater, and it is the principal method for preventing waterborne infectious diseases throughout the world [1]. However, several studies have reported that the effectiveness of this process is reduced by turbidity, suspended solids and the presence of nitrogen compounds such as ammonia and nitrite [3]. Furthermore, the use of chlorine in wastewater gives rise to undesirable by-products suspected to pose a hazard to humans and the environment [5].
Infiltration percolation is a rustic and extensive purification technique that it is capable of completely oxidizing and decontaminating wastewater. Infiltration percolation is an extensive treatment process aimed to eliminate organic pollution, to oxidize ammonium and to remove pathogens [6]. This process has been increasingly used for the treatment of primary or secondary wastewater effluents because of its low energy and requirements maintenance [7]. The sand filter system revealed the problem of clogging by solids and other composites, which could be controlled daily through manual or chemical cleansing of the systems. This problem constitutes the main limitation for the application of this treatment system for municipal wastewater without forgetting the disponibility of great area to be occupied by the construction of a sand basin.
Currently, UV irradiation is considered as one of the best alternatives to chemical disinfection of water, especially chlorination [8]. This is justified when the water to be treated must fulfil certain conditions to obtain an optimal effect of UV irradiation. This can be solved by the application, from the beginning, of a filtration system as disc filter or pressure sand filter that can enhance the quality of water such as turbidity, hardness, suspended solids, iron, manganese, humic acids. These later parameters of water quality are disruptive factors of UV disinfection (USEPA) [9].
The first aim of this work was to determine the performances of the Dissa infiltration percolation basin in the oxidation of organic matter and nitrogen. The second aim was to assess the microbiological quality of different effluents issued from sand filter, signalled by several authors as tertiary treatment. In contrast, in this study, these system worn as secondary treatment and ultraviolet technologies used as tertiary treatment in order to ameliorate the physical-chemical and microbiological characteristics of wastewater, respectively. The determination of the UV irradiation doses required to destroy E. coli, faecal coliforms and Pseudomonas aeruginosa from a secondary effluent provided by Gabes City wastewater treatment plant, for irrigation purposes, was a third objective.
Materials and Methods
Experimental device
Two phases of wastewater treatment were set in the operation: percolation-infiltration sand filter and UV irradiation disinfection monolamp reactor installed as shown in Figure 1. The experiments were conducted in 100 m2 sand filters located in the Dissa agriculture area in the north of Gabes City (southeast of Tunisia). The sand filter is a trapezoidal basin with 2 m in height and filled with 30 cm of coarse gravel and 1.5 m of sand. The mean grain size of sand (d50) is 0.26 mm and an effective size of 0.8 mm and of high uniformity (Cu=1.6). The filtration system operated with an upward flow at 5.0 m3/m2h of hydraulic loading. Cleaning phase was manual, according to head loss (maximum 10 m) and using filtrated water mixed with 10 mg/l of chlorine (Figure 1). A polyethylene pipe was used drilled with 0.5 cm holes to drain filtered water out.
In previous work of Boukchina et al., [10], the optimum hydraulic loading rate to improve primary wastewater quality by an intermittent sand filter for a single application was evaluated to 27 cm/d. In this study, the operational mode conditions rotated through a 7-day cycle consisting of 4-day flooding period during which the basin received a volume of 27 m3/d of primary wastewater effluents, and a 3-day drying period during which the basin is allowed to dry out thoroughly. The wetting/drying operation is done for several purposes, mainly the maintenance of aerobic conditions in the upper soil layers [11].
The system was equipped with an automatic cleaning system according to head loss (maximum 20 m), using filtrated water. A cleaning phase with chlorinated (20 mg/l) filtrated water was carried out daily. Feeding of each process was carried out through independent pumping, using water from secondary sedimentation effluent and in the range of ambient temperatures of 25 and 30°C.
Experimental methodology and analytical parameter determinations
All the systems of percolation-infiltration operated continuously, and samples of water were taken manually and daily. Faecal coliforms, E. coli and P. aeruginosa were analyzed as microbiological parameters in all water samples and some physico-chemical parameters, mainly chemical oxygen demand (COD), nitrates (N-NO3), Kjeldahl nitrogen (NTK), ammonium (N-NH4) and Phosphorus (PO43-), were investigated during a period of 7 months of functioning of the sand filter systems. The techniques and methods followed for the collection, preservation and analysis were those given by (Rainwater and Thatcher, Brown et al., ICMR, Hem, APHA) [12-16]. Samples were analyzed for pH and electrical conductivity (EC) using a handheld pH and EC meter (HI 9811-0; Hanna Instruments, Woonsocket, RI) immediately after sample collection.
For bacteriological analysis, water samples were collected in sterile glass bottles of 1L and analyzed immediately after collection within the 24 hours. The enumeration of thermotolerant coliforms (faecal coliforms) and E. coli was studied using the membrane filtration procedure according to ISO 9308-1 [17], using the double layer of tryptic-bile-agar and tryptic-soy agar (Difco), respectively. The colony count was calculated from the arithmetic mean of three membrane filter counts and expressed as colony forming unit (CFU).
All faecal coliforms isolated in the samples were identified using the bacterial identification system API 20 E (Bio Meriwux, Marcy d’Etoile, France).
On the other hand, the most-probable-number (MPN) technique was used for detecting and enumerating Pseudomonas aeruginosa in wastewater. Asparagine and acetamide broths were employed, respectively, as presumptive and confirmative MPN tests and as described in the 13th edition of Standard Methods for the Examination of Water and Wastewater (Anita and Robert) [18].
Wastewater sampling and UV light treatments
At a depth of 150 cm of the sand filter, in the center and in the periphery of the basin, two UV reactors referenced respectively R1 and R2, were installed at the output of two horizontally drum filters (Figure 1). One is transmitted from the periphery and the other of the center.
The UV irradiation device is a closed cylindrical steel reactor. It is equipped with a low-pressure mercury discharge lamp with a power of 15 Watts and protected by a quartz sleeve, placed in the axis of the irradiation room and emitting an average UVC light of around 25 mW.cm-2 at wavelengths of 253.7 nm.
Samples of the influent and the secondary effluent, deducted from the output of the sand filter, were collected in sterile glass bottles for microbiological analyses. A low-pressure UVC lamp of a power of 15 Watts was applied to treat a flow-rate from 500 to 1,100 l/h, with nominal wavelength of maximum light intensity of 254 NM. This lamp had about 80% of the radiation around the maximum wavelength and the intensity was about 25 mW.cm-2.
The installation was designed to treat a sample of 1.000 ml, irradiated for short periods of 6, 10 and 16 seconds. According to these data, the doses provided were: 36, 60 and 96 mW.s.cm-2, respectively. The second objective of this study is to apply later the UV dose able to give the highest abatement for each strain examined in the process of UV treatment in order to compare their rates of income during the various steps in the treatment plant. Before each treatment, the lamp was cleaned up with bidistilled water. After the irradiation, samples were ready for microbiological determinations. All irradiation experiments were performed at laboratory temperature of (25 ± 5)°C.
UV dose determination
Definition and calculation of the efficient UV dose in the UV disinfection reactor are important and at the same time a difficult element to control [7].
Microbial inactivation depends on the UVC dose which is described as UV light intensity multiplied by the exposure time. As seen above, it is possible to calculate the intensity in mW.cm-2 based on the assumed UVC power emission of the lamp. However, it is still necessary to control the exposure time of a particular particle (microorganism), during its passage through the irradiation chamber.
The dose of UV radiance (D) expressed in mW.s.cm-2 in a point X of the irradiation room is the product of the intensity (illumination) (I) of the radiation expressed in mW.cm-2 in this point and the time of exposure (s) of water in the reactor (tc).
Where, Dx, Ix and tc are the dose in the point X (mW.s.cm-2), the UV intensity (illumination) in the point X (mW.cm-2) and the time of exposure in second, respectively.
Or, In our approach and in order to model the hydrodynamic flow in the reactor and the short distance between the outlet of the filter and the UV reactor, the average residence time in the irradiation room of the UV reactor is calculated experimentally using the time of passage theoretically observed (6, 10 and 16 sec) and for all flows tested without resorting to the technique of chemical tracing.
Results and Discussion
The performance of the sand filter system concerning the removal of physical-chemical parameters
During the experiment, COD of influent showed an average value of 235 mg O2/l. The removal of the carbon is satisfactory during the winter with a mean output of 77% in the center of the basin and 65% in its periphery at 1.5 m depth. The depth of 75cm allowed eliminating 50% of the COD in the center of the basin, and 40% in its periphery, with the remaining contents of the order of 83 and 94 mg O2/l, respectively (Figure 2).
The result showed that the superficial layers of filter played an important role in the removal of the COD; therefore about 50% of the organic load is eliminated already after 75 cm of filtration depth. It is important to indicate that the carbon pollution constituted the principal factor in the development of microbial biomass in the filter. This biomass developed itself therefore less in the superficial layer depth and has important consequences on the management and the durability of the system. A depth of 150 cm appeared sufficient for the elimination of the organic matter. Bali et al. [19] showed also that the devices of infiltration were very effective for the removal of the wastewater organic matter content, and that the major part of removal took place in the superficial layers of the filter.
The average concentration of orthophosphates registered in the influent during the period of study was about 52 mg/L. The depth of 75 cm allowed removing about 50% of the phosphorus in the center of the basin, and around 62% in its periphery. The elimination of the phosphorus was relatively variable for the same depth; it was higher in the periphery than in the center of the basin. The outputs reached 62% at 75 cm and 75% at 150 cm depth; therefore the global output pass extensively out of the basin and it is about 25%. According to Metal, the performances of the systems of infiltration-percolation in the elimination of the orthophosphates depend on electro-chemical conditions of the mass filter, and soon the mineralogical composition of the sand filter.
Organic nitrogen and ammonium contents revealed good performance process in the removal of nitrogen pollution. The retention of the Kjeldahl nitrogen is highly effective during the period of drying. Approximately 95% of this nitrogen was retained in the sand filter. On the other hand, we have not registered sensitive variations of the total nitrogen remaining in the percolate at different depths. At 75 cm depth, the elimination of total nitrogen is already raised with an output of 85% in the center and 78% in the periphery of the basin, and the contents are 4.8 and 6.1 mg/l, respectively. At 150 cm of filter depth, the total nitrogen has been eliminated at the rate of 96% in the center and 92% in the periphery, with average vestigial contents of 1.4 and 2 mg/L, respectively. The nitrification at 75 cm of depth was globally similar to the one of 150 cm. The content of the filtrated water in nitrates was around 15 mg/L whereas it reached 30 mg/L at the depth of 75 cm. The increase of nitrate content observed at 75 cm depth as compared to the one registered at 150 cm could be explained by an operation of washing of the nitrates accumulated in the sand filter during the previous drainage period, and also it may come from oxidization of ammonium adsorbed during the previous alimentation. These results confirmed the ones of Bancolé [20] that proved a big part of the nitrogen will be fixed in the first centimeter layer of the sand filter.
Abatement of bacteria in the sand filter system according to the depths
The removal of the fecal Coliform, Esherichia coli and the P. aeruginosa recorded in treated wastewater was an average of about 1 Ulog (90%). The residence times of wastewater in the sand filter was short, in the score of minutes that follow the application of the volume of wastewater; the porous character of the mass filtering was saturated by the very loaded water in organic matter. Indeed, these surroundings are not favorable to the elimination of bacteria. The bacteriological criteria of no restraining treated wastewater reuse are satisfied extensively. Therefore at 75 cm of depth filter, the bacterial abatement was on average around 3 Ulog, and the last 75 cm of the sand filter played an essential role in the sanitary quality of treated wastewater. This result is comparable to that found by Bali et al. [19] in a similar percolation-infiltration study. These authors attributed the microbial removal to the real residence time in the sand filter, and to the temperature of water. Therefore after 15 days of drying (aeration, ventilation), we noted a better tendency to decrease the number of these bacteria in treated water at different depths (Figure 3). Indeed, the microbiological quality of the filtrate is slightly better than the one registered in the influent with a tendency of the maximum removal rate in the center of the filter basin than in the periphery, and this tendency was valuable for all depths. So, it seemed that the logarithm of the concentration of the bacteria decreases in a linear way according to the filter depth and this result was confirmed by the work of Bancolé [20]. According to the study of Bali et al. [19], it was the height of the unsaturated part of the sand filter that would affect the removal rate of microorganisms in the similar filter system. This fact would be due to the increase of the residence time in a sand filter system in accordance with the amplification of the filtration depth.
Despite this apparently average percentage, for a No of 107 CFU/ml on average for different bacteria studied, and although strong retention of up to 104 colonies/ml for some strains, the number 103 colonies/ml remaining could cause serious health and environmental problems [17].
Microbiological validation of the UV reactor
In principle, the disinfection performance of a UV reactor is determined based on a series of microbial challenges that are conducted either on full or pilot-scale. During a validation, the UV system is evaluated according to various operational conditions, which may include mainly the water flow rate, the UV lamp power (or relative lamp output), and the number of operational lamps (monoor multi-lamps system). During each test, samples are collected from the influent and effluent of the UV reactor to quantify the microbial abatement associated with the specific operational conditions.
In this study, and as it was shown in Figure 4, the log reduction tendency for faecal coliforms, P. aeruginosa and E. coli, respectively, at the center of the filtering basin and in its periphery at the depth of 150 cm and according to different UV dose applied. It can be observed that P. aeruginosa appeared more UV resistant than faecal coliforms and E. coli, because a higher log reduction of 4 and 3 U-Log respectively, for E. coli and faecal coliforms occurred after an exposure of 16 seconds that corresponds to a dose of 96 mW.s.cm-2. In contrast, after the same exposure time, the log reduction has not exceeded 2 U-Log for P. aeruginosa.
On the other hand, several standardized international guidelines stipulate that the reuse of wastewater requires a decrease in the number of indicators bacterial of about 3 U-log [21]. However, the complexity of current processes and requirements for environmental safety, microbiology, public health and even industry, require the introduction of advanced monitoring systems based on monitoring methodologies built on the principle of analytical redundancy. For this reason, a second standard requires a reduction ratio of the number of P. aeruginosa of the order of 5-log for treated wastewater reuse [8]. These waters are loaded prior to about 107CFU/100 mL of P. aeruginosa.
Similarly, and since it was mentioned in Figure 4, all inactivation processes showed a linear portion whatever the dose, despite the lowest correlation coefficient for some adjustments. In this sense, to improve some of these adjustments, a linear regression was calculated only with data obtained at lower UV doses (< 48 mW.s.cm-2), the correlation coefficient slightly improved for E. coli from 0.87 up to 0.92, for faecal coliforms from 0.55 up to 0.58, and for P. aeruginosa form 0.97 up to 0.98, leading to a better fitting (Results not shown). AENOR Water Quality [22] has reported a gradual flattening at higher UV doses, often attributed to particulate matter in the wastewater. This is consistent with the need to apply UV radiations to wastewater previously clarified, in order to avoid the effect of particles [1].
Because the UV dose provided is a complex function of many variables, UV reactor validation is used to demonstrate the disinfection effectiveness of the system.
As illustrated in Figure 4, an almost total removal of these indicators would be achieved with doses over 96 mW.s. cm-2 corresponding to a UV exposure of 16 sec. Therefore, the use of a dose of 96 mW.s.cm-2 is necessary, firstly to calculate the performance of the UV reactor, and secondly to obtain treated wastewater free from microbes and meets the standards recommended by several standardized international guidelines.
This figure showed that the removal rate for all strains increased according to the UV time exposure. In this sense, samples irradiated during 4 sec achieved a reduction of E. coli, of faecal coliforms and of P. aeruginosa, being of 97, of 94 and of 78%, respectively. These removal percentages changed for E. coli from 94 up to 96%, for faecal coliforms from 78 up to 80%, and for P. aeruginosa from 97 up to 99%, in the case of 8 sec of UV exposure. After 12 or 16 sec, the totality of E. coli, of faecal coliforms and of P. aeruginosa completely disappeared from the growth medium. Data fitted to an exponential equation, with correlation coefficients of (0.78- 0.89) for E. coli, (0.96-0.96) for faecal coliforms, and (0.57-0.66) for P. aeruginosa, on behalf of water sampled at the output of at 150 cm of filtration depth in the center and in the periphery of the basin, respectively.
At 150 cm depth, the quality of the filtrate is slightly better than the influent with still tendency to higher removal in the center than in the periphery of the basin. In addition, an average abatments of bacteria in the center than in the periphery of the basin were calculated for E. coli (64 and 62%) i, faecal coliform (50 and 46%) and P. aeruginosa (62.5 and 59.5%), respectively.
Figure 5 illustrated the UV inactivation rates for all the types of bacteria considered at the depth filter of 150 cm, in the center and in the periphery of the filter basin and using different UV doses, respectively.
The UV irradiation device presented the best microbial removal percentages at 6 sec of UV exposure time, with 87% for E. coli, 84% for faecal coliforms and with 87.5% for P. aeruginosa. With an exposure time of 10 or 16 sec, almost all E. coli, faecal coliforms and P. aeruginosa disappeared completely from the culture media.
This ultraviolet dose is much higher than that reported by Gómez et al. [1], who indicated a value over 35 mW.s.cm-2 for total elimination (N/N0= 0) of faecal coliforms, of E. coli and of coliphages from urban wastewater. These authors used a physical-chemical treatment prior to UV disinfection, assuring an effluent with excellent quality, and 99% of turbidity removal. In this case and based on the curves of Figure 4, a dose of 35 mW.s.cm-2 would remove only 37.2 up 50% of E. coli, 27 up 37.5% of faecal coliform and 10 up 17.5% of P. aeruginosa, as an average. These results are also consistent with those reported by Andreakis et al. [23] who found a significant increase in UV disinfection efficiency with samples sand-filtered. The implementation of UV disinfection facilities in secondary effluents needed a previous treatment in order to reduce suspended solids and turbidity in the wastewater. Sharrer et al. [24] reported a complete inactivation of coliform bacteria at approximately 77 mW.s.cm-2, in a recirculating salmonid culture system. However, these authors indicated that total heterotrophic bacteria in the recirculating system required a UV dosage in excess of 1800 mW.s.cm-2 to achieve a not quite 2 Log10 reduction. Macauley et al. [25] reported an irradiation time of 10 minutes for a total bacteria reduction to less than 1000 cfu/ml in a lagoon with swine wastewater, corresponding to effective doses of 220 and 770mW.s.cm-2 for two lagoons. These authors reported that this technology is unlikely to be economically feasible, due to its high energy consumption. In our experiments, UV doses have been always less than 100mW.s.cm-2. According to Figures 4, a reduction down to 1000 cfu /100 ml for E. coli and faecal coliform or 1000 bacteria /100 ml for P. aeruginosa would need a dose over 24mW.s.cm-2 for all types of bacteria examined. A high removal of these indicators would be achieved with doses over 96mW.s.cm-2.
In this sense, the daily microbiological monitoring of the performance of the UV reactor (R1) by the use of a dose of 96mW.s.cm-2, corresponding to an exposure of 16 sec, at the depth of 150 cm and in the center of the basin was finalized and shown in Figure 5. Therefore, the average concentration remaining in the effluent at the output of the UV reactor (R1 or R2) at 150 cm depth was less than 100 cfu/ 100 mL of E. coli, and of faecal coliform. For P. aeruginosa, the number of bacteria remained was less than 100 bacteria/ 100 mL; this value coincides with the range recommended by several standardized international guidelines [8]. Similarly, Figure 5 showed that the microbiological quality of the filtrated water collected in the center at the depth of 150 cm and at the output of the UV reactor (R1) was slightly better than the one registered in the periphery of the basin (R2).
Conclusions
A great physical-chemical and microbiological performance sand filter in the region of Dissa was reported. Results confirmed that this technique is performed as an advanced treatment system for COD and nitrogen. The experimental study has shown the influence of the filter depth on the output purification of the process. On the other hand, the elimination of the orthophosphate depends on electro-chemical conditions of the sand massif and not too much the thickness of this sand filter. Water quality analyses demonstrated that oxidation activity was mainly located in upper sand layers. Maintaining infiltration surface evenness helps provide uniform infiltration. The UV inactivation rates of E. coli, of faecal coliforms and of P. aeruginosa (log reduction) obtained, respectively, at the output and at 150 cm of filtration depth in the center and in the periphery of the basin have allowed increasing the average rate of elimination of feacal bacteria of about 1 Ulog. The combination of UV irradiation with the technique of infiltration percolation constituted a final step with the aim of removing pathogen microorganisms from the effluents of conventional wastewater treatment plants. It is a method that can be used to improve water quality for possible reuse in unrestricted irrigations.
Acknowledgements
This study is supported by the European Union (Avicenna Project n° 93AVI054). We express great appreciation to all the team of the laboratory of Wastewater Treatment, Borj-Cedria techno-park that contributed to realize this work, particularly Mr Aissaoui, Mr Hachemi and Ms Mabrouki for their help.
References

























Tables and Figures at a glance

image   image   image   image   image
Figure 1   Figure 2   Figure 3   Figure 4   Figure 5