alexa Instructions for Researchers | Open Access Journals
ISSN : 2153-2435
Pharmaceutica Analytica Acta
Like us on:
Make the best use of Scientific Research and information from our 700+ peer reviewed, Open Access Journals that operates with the help of 50,000+ Editorial Board Members and esteemed reviewers and 1000+ Scientific associations in Medical, Clinical, Pharmaceutical, Engineering, Technology and Management Fields.
Meet Inspiring Speakers and Experts at our 3000+ Global Conferenceseries Events with over 600+ Conferences, 1200+ Symposiums and 1200+ Workshops on
Medical, Pharma, Engineering, Science, Technology and Business

Instructions for Researchers

Hideharu Shintani*

1-10-60, Minamidaira, Hino, Tokyo 191-0041, Japan

*Corresponding Author:
Hideharu Shintani
1-10-60, Minamidaira, Hino
Tokyo 191-0041, Japan
Tel: +81425922336
E-mail: [email protected]

Received date: March 17, 2013; Accepted date: March 24, 2013; Published date: March 26, 2013

Citation: Shintani H (2013) Instructions for Researchers. Pharmaceut Anal Acta 4:e147. doi: 10.4172/2153-2435.1000e147

Copyright: © 2013 Shintani H. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

Visit for more related articles at Pharmaceutica Analytica Acta

I am an editorial board of Pharmaceutical Analytical Acta (PAA). I am an analytical chemist and microbiologist.

From the experience of evaluation of several Analytical papers, I found that several contributors do not supply Chemical Structures of the interest to analyze and HPLC or GLC chromatograms. Sometimes description of analytical conditions was insufficient. These are serious points to consider.

Most of analytical chemist can speculate how to analyze when Chemical Figures of interest is in hand. If the compound has COOH or aromatic phenol, ion suppression is necessary by adding acid to lower pH of mobile phase. If the compound of interest has NH2 or alkali compound, it is necessary to add alkali to mobile phase for ionsuppression, otherwise plus charge of the interest may observe and tailing phenomenon of the alkali compound can be observed, especially silica-base column used. If polymer-base column is used, this kind of phenomenon may decrease.

The most difficult task to conquer is the analysis of interest in complicated matrix such as blood. Pre-treatment methods are seriously required. I have studied for simultaneous uremic toxin analysis in blood. I used the automatic solid phase extraction (SPE) equipment for recovery, otherwise if manual procedure is used recovery rate differed significantly due to inconsistent pressure. Blood urea analysis is so hard task as urea did not retain onto C-18 column. Even though urea (NH2(C=O)NH2) is a simple figure compound, simple figure compound is not always easy task to analysis. I analyzed simultaneously urea, uric acid, creatinine, methylguanizine and vitamine B12 in blood. I used the isocratic elution analysis combined with the column switching and immobilized urease column. So it is hard task to analyze simultaneously these compounds. Column is C-18 with polymer base. Column switching procedure is manual, so it is quite hard to reproduce simultaneous analysis with manual procedure at that time (1985).

These compounds are spiked into blood serum and deproteinized with acetonitrile using automated SPE. Recovery of all compounds was almost 100% and reproducibility was satisfactory. Satisfactory reproducibility was more important to analytical chemist. If the pretreatment was conducted with manual, recovery was so fluctuated due to inconsistency of pressure to the pre-column for elution.

Urea did not retain on C-18 column and both acid and alkali compounds are present as the compounds of interest, so ion suppression cannot apply (therefore polymer base column used) and used column switching and immobilized urease column. Immobilized urease column was homemade. At that time I did not consider about the gradient elution, so what will happen when used gradient elution rather than isocratic elution. At that time no reliable and reproducible gradient pump was available in Japan. Today, several superior column, automatic column switching equipment, automatic SPE and reproducible gradient pump are available.

Now, I read several papers submitted to PAA about the analysis of the compounds in blood, no SPE procedure has ever utilized. Automated SPE in complicated matrix can be quite recommended for pretreatment.

Analytical chemistry is advancing day by day, however the most important task is looking at the chemical structure of the interest and can speculate analytical conditions in mind at the beginning. In that meaning I seriously recommend to the contributors to submit chemical figures of interest for speculation of analytical conditions.

The above is my experience I ever conducted as an editorial task.

Thank you very much to supply me the space to submit my comments to PAA.

Select your language of interest to view the total content in your interested language
Post your comment

Share This Article

Recommended Conferences

Article Usage

  • Total views: 11479
  • [From(publication date):
    March-2013 - Aug 23, 2017]
  • Breakdown by view type
  • HTML page views : 7712
  • PDF downloads :3767
 

Post your comment

captcha   Reload  Can't read the image? click here to refresh

Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords