Make the best use of Scientific Research and information from our 700+ peer reviewed, Open Access Journals that operates with the help of 50,000+ Editorial Board Members and esteemed reviewers and 1000+ Scientific associations in Medical, Clinical, Pharmaceutical, Engineering, Technology and Management Fields.
Meet Inspiring Speakers and Experts at our 3000+ Global Conferenceseries Events with over 600+ Conferences, 1200+ Symposiums and 1200+ Workshops on
Medical, Pharma, Engineering, Science, Technology and Business

Investigation of Correction Method of Recovery Effect and Motion Blur for SUV Quantification in FDG PET/CT in Patients with Early Lung Cancer

Noriyuki Kadoya1*, Yukio Fujita1, Kengo Ito1, Suguru Dobashi2, Ken Takeda2, Kazuma Kishi3, Takaya Yamamoto1, Rei Umezawa1, Toshiyuki Sugawara1, Tomohiro Kaneta4, Haruo Matsushita1 and Keiichi Jingu1

1Department of Radiation Oncology, Tohoku University School of Medicine, Sendai, Japan

2Department of Radiological Technology, School of Health Sciences, Faculty of Medicine, Tohoku University, Sendai, Japan

3Department of Radiation Technology, Tohoku University Hospital, Sendai, Japan

4Department of Diagnostic Radiology, Tohoku University School of Medicine, Sendai, Japan

*Corresponding Author:
Noriyuki Kadoya
Department of Radiation Oncology
Tohoku University School of Medicine
1-1 Seiryo-chou, Aoba-ku
Sendai 980-8574, Japan
Tel: +81-22-717-7312
Fax: +81-22-717-7316
E-mail: kadoya.n@rad.med.tohoku.ac.jp

Received date: June 25, 2013; Accepted date: August 26, 2013; Published date: August 29, 2013

Citation: Kadoya N, Fujita Y, Ito K, Dobashi S, Takeda K, et al. (2013) Investigation of Correction Method of Recovery Effect and Motion Blur for SUV Quantification in FDG PET/CT in Patients with Early Lung Cancer. J Nucl Med Radiat Ther 4:162. doi:10.4172/2155-9619.1000162

Copyright: © 2013 Kadoya N, et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

Visit for more related articles at Journal of Nuclear Medicine & Radiation Therapy

Abstract

Objective: We investigated the effects of partial volume and respiratory motion using a National Electrical Manufacturers Association (NEMA) phantom and proposed a simple method for correction of maximum standardized uptake value (SUVmax) for respiratory motion in early lung cancer. Methods: The maximum recovery coefficient (RC) in static mode were measured using the NEMA phantom and a dynamic moving platform. The phantom on the platform was either at rest or moving sinusoidally along the longitudinal axis of the scanner to simulate respiratory motion. We also calculated estimated RC using our approximation. Results: RC of the sphere of 28mm in diameter decreased from 0.96 to 0.80 and 0.41 with 20 and 50 mm of motion amplitude, respectively. For the sphere of 10 mm in diameter, RC was decreased from 0.40 to 0.18 and 0.08 with 20 and 50 mm of motion amplitude, respectively. Our results showed that RC decreased with increase in motion amplitude. Average percentage differences between measurement and estimation in the sphere of 37, 28, 22, 17, 13 and 10 mm were -1.8 ± 3.7, -3.1 ± 11.3, -2.8 ± 10.5, -8.1 ± 6.6, -7.0 ± 12.3 and -1.8 ± 12.2 %, respectively. This result showed that our simple correction method could estimate SUVmax with moderate accuracy. Conclusions: Our results clearly demonstrated that RC decreases with increase in motion amplitude, as expected. Our simple correction with moderate accuracy method could not precisely estimate RC. However, the estimated values agreed with the measurements. Thus, our methods could be used in clinical practice to calculate the approximate SUVmax for lung cancer patients undergoing radiotherapy showing the malignancy grading for early lung cancer.

Keywords

SUV quantification; FDG PET/CT; Early lung cancer

Introduction

Whole body F-18 fluoro-2-deoxyglucose (18F-FDG) positron emission tomography/computed tomography (PET/CT) has become an important method for detecting tumors, planning radiation treatment and evaluating response to therapy. However, PET/CT imaging of the lung and abdomen region is generally affected by patient respiratory motion, which can lead to underestimation of maximum standardized uptake value (SUVmax) of a region of interest, overestimation of tumor volume and mismatched PET and CT images that yield attenuation correction errors, registration errors and tumor mislocalization [1-3].

The effects of partial volume and respiratory motion on SUV were investigated in previous studies [1-9]. The most widely used method to correct for respiratory motion is repiratory-gated PET/CT, which divides PET data into different gates based on either temporal phase or respiratory displacement information with potential 4D CT for phase-matched attenuation correction. Guerra et al. showed that the respiratory-gated PET/CT technique is a valuable clinical tool for diagnosing lung lesions, improving quantification and confidence in reporting, reducing 3D undermined findings and increasing the overall accuracy in lung lesion detection and characterization [10]. However, there are few hospitals in Japan in which this technique has been introduced. It is better to correct SUV for respiratory motion in clinical practice. A study on 108 patients showed that SUVmax increased as much as 51.8% on average from free-breathing PET to deepinspiration- breathhold PET/CT for lesions in the lower lung region [11]. However, the breath hold PET/CT cannot correct the partial volume effect. Though the usage is limited to lung cancer patients undergoing radiotherapy, we proposed a simple method for correction of SUV in the lung region using tumor size and motion displacement.

In this study, we investigated the effects of partial volume and respiratory motion using a phantom and the usefulness of a simple method to correct SUV for respiratory motion to know the actual malignancy in early lung cancer.

Materials and Methods

Equipment and imaging protocol

A PET-CT scanner (True Point Biograph 40, Siemens, Erlangen, Germany) was used to acquire data. The PET-CT scanner is composed of a lutetium oxyorthosilicate (LSO) crystal detector, 52 rings (84.2 cm in diameter) and 32448 crystal numbers that give a transaxial field of view (FOV) of 60.5 cm and an axial FOV of 21.6 cm.

The imaging protocol used in this study is the most widely used method in clinical applications. CT data were acquired using a helical CT scan with scanning parameters of 140 kV, 75mA, and 2.5mm in slice thickness. Following the CT scan, PET data were acquired for 5 min per bed position. During the helical CT scan and PET emission scan, the targets in the phantom were either at rest or moving sinusoidally along the longitudinal axis of the scanner to simulate respiratory motion.

PET images (168×168×47 for a 60.5 cm transaxial FOV with a slice thickness of 2.5 mm) were reconstructed using an ordered subset expectation maximization (OSEM) algorithm (14 subsets, 6 iterations and 8 mm FWHM Gaussian post-filter ) and were corrected for attenuation using the CT attenuation map in Hounsfield units (HUs). Corrections for scatter and random events were also incorporated in the OSEM algorithm. These reconstruction parameters are usually used in standard clinical protocols for patient scans.

Phantom study

The NEMA IEC body phantom shown in figure 1 was designed in accordance with the recommendations of the International Electrotechnical Commission (IEC) and modified by the National Electrical Manufacturers Association (NEMA) to evaluate whole-body PET performance. The phantom consists of a body phantom (18 cm in length and 9.8 L) and an inset with six hollow spheres of various sizes. In order to simulate respiratory motion using the NEMA phantom, we used a dynamic thorax platform (Model 008PL; Computerized Imaging Reference Systems, Norfolk, USA). The NEMA phantom was placed on the platform and moved along the longitudinal axis of the scanner to simulate respiratory motion.

nuclear-medicine-NEMA-phantom-placed

Figure 1: The NEMA phantom placed on the dynamic thorax platform. The phantom moved along the longitudinal axis of the scanner.

Recovery coefficients

In order to investigate the effect of target size, phantoms with hollow spheres of 0.5, 1.2, 2.6, 5.6, 11.5 and 26.5 ml (10, 13, 17, 22, 28 and 37 mm in i.d., respectively) filled with 18F-FDG were inserted. To simulate the measurement of 18F-FDG for lung cancer, the NEMA phantom not filled with water was used. For data analysis, the recovery coefficient (RC) in the volume of interest (VOI) was defined as follows:

image (1)

Where Aobserved is activity observed in the VOI (Bq) and Astatic, 37mm is activity in the sphere of 37mm in i.d. without movement. This value was regarded as ‘true’ activity in the VOI. RCmax, calculated using the maximum activity concentration, is more sensitive to image noise than in RCmean, calculated using mean activity concentration in the VOI. However, RCmean can easily vary based on the VOI, which is difficult to determine in a moving object [4]. Therefore, we used RCmax in this study because of its consistency in data analysis, especially for the respiratory induced moving target. To detect the image pixel having maximum activity concentration in each target sphere, MATLAB (The Math Works, Inc., Natick, MA) was used.

Respiratory motion

To simulate different respiratory speeds, the phantoms were translated sinusoidally with the following formula:

image (2)

where y0 is the baseline position at exhalation and A is the amplitude of motion. The peak-to-peak amplitudes were 0, 5, 10, 20, 30, 40 and 50 mm. The respiratory cycle period, τ was fixed at 4.5s. This representative breathing period was determined from a previous paper [2]. The value of n was set to 4. A previous study showed that modeling the breathing curve using n=4 closely resembles free breathing motion since exhalation takes about twice as long as inhalation [12]. The curves are shown in figure 2.

nuclear-medicine-dynamic-thorax-phantom

Figure 2: Motion curves of the dynamic thorax phantom. The peak-to-peak amplitudes were 0, 5, 10, 20, 30, 40 and 50 mm.

Simulation

In order to investigate the effect of volume mismatch on attenuation correction, measurements with movement were simulated using measurement. First, we created the probability density function for the target location. Next, simulation of measurement with movement was calculated to convolute the static measurement with its probability density function.

Results

PET images are shown in figure 3. These images clearly show that the activity decreases with increased motion amplitude, as expected. Figure 4 shows RC as a function of sphere diameter. RC of the sphere of 28mm in diameter decreased from 0.96 in a static mode to 0.80 and 0.41 with 20 and 50 mm of motion amplitude, respectively. For the sphere of 10 mm in diameter, RC decreased from 0.40 to 0.18 and 0.08 with 20 and 50 mm of motion amplitude, respectively. Figure 5 shows RC as a function of motion amplitude. The results show that RC decreases with increase in motion amplitude.

nuclear-medicine-PET-motion-amplitudes

Figure 3: Axis images of PET with motion amplitudes of (a) 10, (b) 20 and (c) 40 mm.

nuclear-medicine-RC-sphere-diameter

Figure 4: RC vs. sphere diameter.

nuclear-medicine-RC-motion-amplitude

Figure 5: RC vs. motion amplitude.

Simulated RCs with sphere of 10, 17 and 28 mm in diameter are shown in figure 6. The results of simulation show almost the same trend of that of measurements. However, differences between results of simulations and measurements become large with increase in motion amplitude.

nuclear-medicine-measurements-simulated-values

Figure 6: Comparison of measurements and simulated values.

Next, we made a correction formula using obtained data. The formula was comprised of two terms: one term approximated the reduction by the partial volume effect and the other term approximated reduction by the motion blur. The first term was decided to fit the result with no motion using a sigmoid curve. Sigmoid curve made the goodness-of-fit measure between the estimated and measured values (Figure 7). Second term was decided to fit the measurement using an exponential function. Finally, we made the following formulas to estimate the RC.

nuclear-medicine-sigmoid-curve-measured

Figure 7: Fitting of estimations calculated by a sigmoid curve to measured data.

image (3)

image (4)

Where x is sphere diameter, y is motion amplitude, and a, b, c, d, e and f are constant. When the estimated value in second term was greater than 1.0, we took 1.0 for the estimated value in second term. Estimated RC could be calculated by only two measured values (sphere diameter and motion amplitude). A comparison of measurements and estimations are shown in Figure 8. The estimated values using this approximation almost agreed with the measurements. Average percentage differences between measurement and estimation in the sphere of 37, 28, 22, 17, 13 and 10 mm were -1.8 ± 3.7, -3.1 ± 11.3, -2.8 ± 10.5, -8.1 ± 6.6, -7.0 ± 12.3 and -1.8 ± 12.2 %, respectively. This result showed that the estimated values using this approximation had relatively good agreement with the measurements. Average percentage differences between measurement and estimation in the motion amplitude of 0, 5, 10, 20, 30 , 40 and 50 mm were -0.3 ± 5.0, -1.0 ± 7.1, 2.2 ± 6.2, 2.0 ± 4.6, -1.1 ± 4.2, -9.5 ± 6.9 and -21.0 ± 7.4 %, respectively. This result showed the differences between two values increased with increase in motion amplitude.

nuclear-medicine-measurements-estimation

Figure 8: Comparison of measurements and estimation.

Discussion

In this study, we investigated the impact of respiratory motion and volume effect on SUVmax. Figures 3-5 clearly demonstrate the effects of these two factors and show that the measured value decreases with increase in motion amplitude, as expected. These findings corroborate those of Park et al. [2].

In the present study, the difference between measurements and simulated values became greater with increase in motion amplitude (Figure 6). In a PET/CT procedure, the difference in acquisition time of a CT scan (a few seconds) from that of a PET scan (5 min) can lead to a misalignment between CT and PET images, resulting in an incorrect attenuation correction map and consequently incorrect SUVmax values. In addition, the image noise during a PET scan was not considered in the simulation since only the measurements in static mode were used. Liu et al. reported that SUVmax measurement in clinical practice is affected by image noise [3]. These two factors may have a negative impact on the agreement of measured and simulated values. Our results showed that it was difficult to simulate RC with motion using the data with no motion.

For the correction method, the estimated value obtained by Equation (3) and (4) relatively had good agreement with the measurements. However, the differences increased with increasing the motion amplitude. We used an exponential function to fit the measurements. As mentioned above, measurement of SUVmax was affected by the misalignment between attenuation correction CT and PET images. To estimate actual SUVmax, the effect of this misalignment should in the equation. Furthermore, our purpose was not to estimate actual SUV but to estimate a reliable value using a simple method. Moreover, since the reproducibility of SUVmax measurements is poor, complete agreement of the estimated value with the measured value is meaningless [13].Thus, in clinical practice, correction of SUVmax using our equation is better than no correction. Since this correct method is simple and needs no additional device or no more imaging time and can use patient’s data, it could be used in many hospitals in which respiratory motion artifacts are not corrected. However, when this approximation created by measurements in a phantom study is used for patients, it is necessary to consider the fact that the respiratory pattern and cycle is not regular in all patients. That is, as the estimated values were calculated using two values (tumor size and tumor displacement), there was no consideration of the change in respiratory pattern during acquisition of a PET image. Liu et al. analyzed a large number of respiratory traces (1295) and reported that about 40% were not regular respiratory cycles [3]. Furthermore, the actual tumor in the lung cancer moves in three dimensions. Further investigation of these effects of irregular respiratory and three-dimensional motion is necessary.

Conclusions

We investigated the impact of respiratory motion and volume effect on SUVmax. Our results clearly demonstrated those effects and showed that the measured value decreases with increasing in motion amplitude and tumor diameter, as expected. Our simple correction method could estimate SUVmax with moderate accuracy. Thus, our method could be used in clinical practice to calculate an approximate SUVmax value showing actual degree of glucose metabolism in early lung cancer.

References

Select your language of interest to view the total content in your interested language
Post your comment

Share This Article

Recommended Conferences

Article Usage

  • Total views: 11854
  • [From(publication date):
    August-2013 - Aug 23, 2017]
  • Breakdown by view type
  • HTML page views : 8085
  • PDF downloads :3769
 

Post your comment

captcha   Reload  Can't read the image? click here to refresh

Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

Agri, Food, Aqua and Veterinary Science Journals

Dr. Krish

agrifoodaquavet@omicsonline.com

1-702-714-7001 Extn: 9040

Clinical and Biochemistry Journals

Datta A

clinical_biochem@omicsonline.com

1-702-714-7001Extn: 9037

Business & Management Journals

Ronald

business@omicsonline.com

1-702-714-7001Extn: 9042

Chemical Engineering and Chemistry Journals

Gabriel Shaw

chemicaleng_chemistry@omicsonline.com

1-702-714-7001 Extn: 9040

Earth & Environmental Sciences

Katie Wilson

environmentalsci@omicsonline.com

1-702-714-7001Extn: 9042

Engineering Journals

James Franklin

engineering@omicsonline.com

1-702-714-7001Extn: 9042

General Science and Health care Journals

Andrea Jason

generalsci_healthcare@omicsonline.com

1-702-714-7001Extn: 9043

Genetics and Molecular Biology Journals

Anna Melissa

genetics_molbio@omicsonline.com

1-702-714-7001 Extn: 9006

Immunology & Microbiology Journals

David Gorantl

immuno_microbio@omicsonline.com

1-702-714-7001Extn: 9014

Informatics Journals

Stephanie Skinner

omics@omicsonline.com

1-702-714-7001Extn: 9039

Material Sciences Journals

Rachle Green

materialsci@omicsonline.com

1-702-714-7001Extn: 9039

Mathematics and Physics Journals

Jim Willison

mathematics_physics@omicsonline.com

1-702-714-7001 Extn: 9042

Medical Journals

Nimmi Anna

medical@omicsonline.com

1-702-714-7001 Extn: 9038

Neuroscience & Psychology Journals

Nathan T

neuro_psychology@omicsonline.com

1-702-714-7001Extn: 9041

Pharmaceutical Sciences Journals

John Behannon

pharma@omicsonline.com

1-702-714-7001Extn: 9007

Social & Political Science Journals

Steve Harry

social_politicalsci@omicsonline.com

1-702-714-7001 Extn: 9042

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords