Make the best use of Scientific Research and information from our 700+ peer reviewed, Open Access Journals that operates with the help of 50,000+ Editorial Board Members and esteemed reviewers and 1000+ Scientific associations in Medical, Clinical, Pharmaceutical, Engineering, Technology and Management Fields.
Meet Inspiring Speakers and Experts at our 3000+ Global Conferenceseries Events with over 600+ Conferences, 1200+ Symposiums and 1200+ Workshops on
Medical, Pharma, Engineering, Science, Technology and Business

Monitoring of Sedation during Neuroaxial Blockade

Guerrero OrriachJose Luis1,2*, Matute Emilio3 , Alsina Estibaliz4 , Del Blanco Brezo5 and Gilsanz Fernando4,6

1Department of Anesthesiology, Virgen de la Victoria Hospital, Malaga, Spain

2PostgraduateResearch, Universidad Autónoma de Madrid, Facultad de Medicina, Spain

3Department of Anesthesiology, Hospital Sanitas La Moraleja, Madrid, Spain

4Department of Anesthesiology, Hospital La Paz, Madrid, Spain

5Department of Anesthesiology, HospitalInfanta Leonor, Madrid, Spain

6Department of Surgery, Universidad Autónoma de Madrid, Facultad de Medicina, Spain

*Corresponding Author:
José Luis Guerrero Orriach
Department of Anesthesiology
Hospital Universitario Virgen de la Victoria
Campus Universitario Teatinos, C.P. 29010, Spain
Tel: 951032051
Fax: 951032051
E-mail: [email protected]

Received date: April 17, 2013; Accepted date: June 21, 2013; Published date: June 24, 2013

Citation: Luis GO, Emilio M, Estibaliz A, Brezo DB, Fernando G (2013) Monitoring of Sedation during Neuroaxial Blockade. J Anesthe Clinic Res 4:324. doi: 10.4172/2155-6148.10003324

Copyright: © 2013 Luis GO, et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

Visit for more related articles at Journal of Anesthesia & Clinical Research

Abstract

Study objective: The arousal state changes during spinal anesthesia. It is not clear if BIS and others devices could monitor the induced neuroaxial blockade sedation. Our objective was evaluate BIS and entropy values when spinal anesthesia is done.

Design: We developed a prospective study. Patients: 40 patients were included in this study, ASA I-III, over 60 years old, undergoing spinal anesthesia, without premedication scheduled for orthopedics procedures.

Intervention: Spinal anesthesia was performed with the unseated volunteer in the lateral decubitus position with a 25-gauge Whitacre needle at L2-L3 space, andanesthesia was done with 12 mg of 0.5% hyperbaric bupivacaine. Patients were positioned supine for 5 min after spinal anesthesia.

Measurements: Observer’s Assessment of Alertness/Sedation OAA/S, response (RE) and state entropy (SE) and BIS, and standard hemodynamic measures.

Main results: Statistical analysis were performed by Wilcoxon test or ANOVA, p<0.05 was considered statistically significant.RE and BIS showed a better correlation with the OAA/S scale values (Pk 0.81 and 0.82) than SE (Pk 0.69). The OAA/S, RE and SE showed significative differences from basal values after 30 min of neuroaxial anesthesia (ANOVA p<0.05). BIS showed differences after 40 min (ANOVA p<0.05). There were no differences between BIS and RE values along the study (ANOVA p>0.05).

Conclusions: The spinal anesthesia decreased the cortical activity and these were founded by OAA/S scale and depth anesthetics monitors. OAA/S was a more sensitive value of this induced sedation. BIS and RE showed a better correlation with OAA/S scale than SE.

Keywords

Entropy; BIS; Neuroaxial; Hypnosis

Introduction

The neuroaxial blockade is often used as an anesthetic technique to abolish nociceptive stimuli during surgical procedures. Some articles published recently suggest that neuroaxial techniques are related to decrease of the anesthetics requirements. This level of sedation after neuroaxial anesthesia could be related to sensory input to a reticular activating system decrease because of deep sensory blockade [1-3]. Neuroaxial anesthesia has been done, usually, with intravenous sedation; but if neuroaxial anesthesia gets a good level of sedation, the administration of hypnotic drugs could have adverse effects.

Several monitors based on the quantitative EEG have been tested to check their ability to find the changes in the state of consciousness in the patients were neuroaxial anesthesia was done, with different results [2-4]. Entropy monitors the level of hypnosis of patients through two parameters: state entropy and response entropy [5,6].

Our objective was evaluate BIS and entropy values when spinal anesthesia is done, trying know if entropy monitor was better than BIS when we evaluate the level of sedation in neuroaxial anesthesia. The first aim of our research has been study the relation between the change in the state of consciousness following spinal anesthesia and BIS, RE and SE values; and which of them is more sensitive to detect changes in the level of sedation after a neuroaxial anesthesia.

Materials and Methods

This prospective study was approved by the institutional review board of our hospital. 40 patients were included and informed about the nature of the study and gave written informed consent.

Inclusion criteria were age over 60 yr, American Society of Anesthesiologists physical status classification I, II or III scheduled for orthopedic hip and knee surgery. Excluded from the study were patients with history of any disabling central nervous or cerebrovascular disease, coagulation disorders, patients who had received central nervous system–active drugs and patients with a history of drugs or alcohol abuse and allergic to local anesthetics.

No sedative premedication was used.

After arrival in the OR, an intravenous line was inserted into a large forearm vein and an infusion of lactated Ringer’s solution infused at 15 ml per kg before anesthesia was started and the standard monitorization was done pulse oximetry, electrocardiography, and non-invasive arterial blood pressure recordings every 5 min.

Electroencephalogram was recorded using the Aspect A-2000 BIS® monitor version XP Aspect Medical Systems, Newton, MA and the Datex-Ohmeda S/5 Entropy Module Datex-Ohmeda Division, Instrumentarium Corp, Helsinki, Finland.

Spinal anesthesia was performed with the unseated volunteer in the lateral decubitus position with a 25-gauge Whitacre needle at the L2-L3 space, and the injection with 12 mg 0.5% hyperbaric bupivacaine was done. Patients were positioned supine for 5 min.

Block height and motor block were measured with alcohol and Bromage scale assessed after neuroaxial anesthesia and during the surgery, every 5 min for the first 30 min and then every 10 min until block resolution.

Heart rate (HR), non-invasive mean arterial blood pressure (MAP), and oxygen saturation were measured and registered at every point of measurement AS/3; Datex-Ohmeda Division, Instrumentarium Corp. The OAA/S score was also recorded every five minutes. BIS, RE and SE were recorded every 5 min.

We have done statistical analysis to evaluate if EEG variables, hemodynamic variables, had changed after neuroaxial anesthesia. For this purpose, the EEG variables differences between pre-anesthesia values and intraoperative were analyzed using the Wilcoxon signedranks test. Differences between BIS, RE and SE pre-anesthesia and intraoperative were analyzed by two-way ANOVA. The correlation between OAA/S and SE, RE and BIS was done with the model independent prediction probability Pk. Graph-Pad Prism 3.0 Graph- Pad Software, San Diego, CA, USA was used for the statistical analyses. Data are expressed as median and range, unless otherwise indicated.

Data for times of surgical procedures and duration of spinal anesthesia were normally distributed and are expressed as mean ± SD.

Results

All patients had successful spinal anesthesia and did not require any additional analgesic or sedative drugs.

The median of surgical procedure time was 53 min range 45-72.

BIS, SE and RE had significant variation between pre and postneuroaxial anesthesia ANOVA p<0.05 (Figure 1).

anesthesia-clinical-research-neuroaxial-anesthesia

Figure 1: RE, BIS and SE values after neuroaxial anesthesia.

Age (yr) 71 (60-83)
Weight (kg) 69 (60-81)
Height (cm) 1.64 (1.61-1.69)
Gender (male/fenale) 20 (12/8)
ASA (I/II/III) 4/10/6
Hip surgery/Knee surgery 32/8
Duration of surgery 64 (42-78)

Table 1: Demographic data (n=40). Values are median (range) or n.

OAA/S decreased from five at baseline to four ranges 3–5 after 30 minutes P<0.05.

Median level of spinal anesthesia was T10 rangeT8-T11; arterial pressure had not significant variation.

RE and BIS demonstrate a better correlation with the OAA/S scale values (Pk 0.81 and 0.82 respectively) than SE (Pk 0.69). The OAA/S, RE (basal value: 97 ± 6; after 30 min.: 81 ± 16) and SE (basal value: 89 ± 5; after 30 min: 77 ± 12) shows a significant differences from basal values after 30 min of neuroaxial blockade. The BIS (basal value: 98 ± 5; after 40 min.:82 ± 13) show differences after 40 min.

Discussion

Our study found changes in the values of the hypnosis monitors RE, SE, BIS, after spinal anesthesia, because the increase in the state of sedation. The physiological mechanism is that spinal anesthesia blocks ascending somatosensory driven onto reticular-thalamuscortical projection pathways, reducing their excitability and decreasing the arousal level of the brain [1,7]. Ben-David et al. found a lower requirements of benzodiazepines in patients who neuroaxial anesthesia was done for the same level of sedation, when them were compared with patients in which spinal anesthesia hadn´t been done [8] and a decrease in sevoflurane requirements in those patients under general anesthesia combined with epidural analgesia [9].

Several studies have tried to assess the possibility of measuring this state of sedation through various monitors of hypnosis BIS, PSI, reaching contradictory conclusions [10,11].

We have tried to evaluate if RE, SE and BIS are able to show the level of hypnosis after neuroaxial anesthesia when compared with a sedation scale (OAA/S) [12]. We have found that the results between the hypnosis monitors values and the level of sedation are not correlated. We have done a statistical prediction of probability analysis PK not included in previous studies, because in our opinion this would be the best valid test in order to compare the two sedation scales. PK is a measure suited to evaluating and comparing aesthetic depth indicators showing the probability that an indicator can predict correctly the rank order of an arbitrary pair of distinct observed aesthetic depths. Our results show significant variations of the 3 parameters of hypnosis. Bispectral index and response entropy get the highest Pk values pK BIS: 0.81, pK RE: 0.82. SE was the worst parameter pK SE: 0.69. BIS and RE changed with the changes of level of sedation, but these relations are not strong enough because the accuracy of these monitors in sedation state is weaker than in anesthesia levels. Vanluchene published that BIS and entropy were not able to evaluate with accuracy the change for the sedation states without a loss of the conscience level, between levels 5 to 3 in the OAA/S scale, but in the anesthesia state prediction of the probability of both monitors was excellent [13].

It seems contradictory to conclude that there is a change in level of consciousness and SE is a less valid indicator to detect this change. A possible explanation would be that changes in the EEG pattern in the stages of light sedation are with high frequency waves. The state entropy does not collect some of these waves. This may be one of the reasons why prediction of probability of BIS and RE is more accurate than SE.

Ishiyama et al. showed as epidural anesthesia decreases the BIS during general anesthesia, but in epidural in which the sensory block reached high thoracic sensory blockade but in our study we don´t get high thoracic levels, so that is the difference between our findings and Ishiyama´s result [14].

On the other hand, we wanted to know if changes obtained in BIS, RE and SE values had a good relation with the changes in levels of sedation [6].

Limitation of our study is an observational one and not a randomized and blinded trial, because we did not use a control group. Other limit is that we did it while surgery was taking place, but neuroaxial anesthesia was not finished and we could not know how hypnosis monitors would correlate with the recovery of neuroaxial anesthesia.

In conclusion, the spinal anesthesia decreased the cortical activity after 30 min, as measured by OAA/S and depth anesthetics monitors. OAA/S was a more sensitive value of this induced sedation. BIS and RE showed a good correlation with OAA/S scale but it was worse than general anesthesia. SE does not seem to have a good correlation with the induced sedation state.

References

Select your language of interest to view the total content in your interested language
Post your comment

Share This Article

Recommended Conferences

Article Usage

  • Total views: 11786
  • [From(publication date):
    June-2013 - Dec 14, 2017]
  • Breakdown by view type
  • HTML page views : 8021
  • PDF downloads : 3765
 

Post your comment

captcha   Reload  Can't read the image? click here to refresh

Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

Agri & Aquaculture Journals

Dr. Krish

[email protected]

1-702-714-7001Extn: 9040

Biochemistry Journals

Datta A

[email protected]

1-702-714-7001Extn: 9037

Business & Management Journals

Ronald

[email protected]

1-702-714-7001Extn: 9042

Chemistry Journals

Gabriel Shaw

[email protected]

1-702-714-7001Extn: 9040

Clinical Journals

Datta A

[email protected]

1-702-714-7001Extn: 9037

Engineering Journals

James Franklin

[email protected]

1-702-714-7001Extn: 9042

Food & Nutrition Journals

Katie Wilson

[email protected]

1-702-714-7001Extn: 9042

General Science

Andrea Jason

[email protected]

1-702-714-7001Extn: 9043

Genetics & Molecular Biology Journals

Anna Melissa

[email protected]

1-702-714-7001Extn: 9006

Immunology & Microbiology Journals

David Gorantl

[email protected]

1-702-714-7001Extn: 9014

Materials Science Journals

Rachle Green

[email protected]

1-702-714-7001Extn: 9039

Nursing & Health Care Journals

Stephanie Skinner

[email protected]

1-702-714-7001Extn: 9039

Medical Journals

Nimmi Anna

[email protected]

1-702-714-7001Extn: 9038

Neuroscience & Psychology Journals

Nathan T

neuropsyc[email protected]

1-702-714-7001Extn: 9041

Pharmaceutical Sciences Journals

Ann Jose

[email protected]

1-702-714-7001Extn: 9007

Social & Political Science Journals

Steve Harry

[email protected]

1-702-714-7001Extn: 9042

 
© 2008- 2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version