alexa A Foot Orthotics Study: Commentary | OMICS International
ISSN: 2157-7595
Journal of Yoga & Physical Therapy
Like us on:
Make the best use of Scientific Research and information from our 700+ peer reviewed, Open Access Journals that operates with the help of 50,000+ Editorial Board Members and esteemed reviewers and 1000+ Scientific associations in Medical, Clinical, Pharmaceutical, Engineering, Technology and Management Fields.
Meet Inspiring Speakers and Experts at our 3000+ Global Conferenceseries Events with over 600+ Conferences, 1200+ Symposiums and 1200+ Workshops on
Medical, Pharma, Engineering, Science, Technology and Business

A Foot Orthotics Study: Commentary

Anthony L Rosner*

Department of Kinesiology, International College of Applied Kinesiology, USA

*Corresponding Author:
Anthony L Rosner
Department of Kinesiology
International College of Applied Kinesiology, USA
Tel: 617-734-3397; 617-794-1372
Fax: 617-734- 0989
E-mail: [email protected]

Received date July 22, 2016; Accepted date August 01, 2016; Published date August 08, 2016

Citation: Rosner AL (2016) A Foot Orthotics Study: Commentary. J Yoga Phys Ther 6:255. doi: 10.4172/2157-7595.1000255

Copyright: © 2016 Rosner AL. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

Visit for more related articles at Journal of Yoga & Physical Therapy

Introduction

A recent study was designed to assess the effect of orthotics upon both manual muscle testing and the duration of effects produced by the chiropractic manipulation of the spine [1]. It accomplished this by challenging the manipulation with daily activities (including walking and standing) and determining whether the use of custom foot orthotics prolongs the effects of manipulation which are presumably diminished over time by these activities. Using a means of testing several muscles bilaterally (gluteus maximus, popliteus, lower trapezius, middle deltoid, and neck extensors) in what is known as an applied kinesiology technique, it followed the natural history of indicator muscles of back pain upon their testing with or without orthotics and correlated these results with those of pain and disability, determining whether manual muscle testing results might be predictive indicators of pain and disability as well. The design of the investigation was a randomized controlled trial, in which one group received a custom fitted orthotic sole and the other a contoured sham device. The effects of manipulation were assessed by two primary outcome measures: (1) the Quadruple Visual Analog Scale (VAS) and (2) the Roland-Morris Disability Scale (RMS), and two secondary measures: (1) the determination of the number and location of vertebral fixations [FIX] as determined by palpation and challenge, (2) the determination of the number of weak muscles [WkMus] by a qualified AK clinician, the muscles having been considered relevant by the tenets of applied kinesiology (AK).

The conclusions were the following:

1. Both groups improved on all VAS, RMS and WkMus from intake to the final visit.

2. Only the sham group yielded significant improvements in FIX.

3. No outcome measures registered statistical difference between the groups at any time point.

4. Those who wore custom orthotics longer each day showed trends toward greater improvements in measures the number of weak muscles tested, quadruple numerical pain rating scale, and the Roland-Morris questionnaire.

5. Correlations between all outcome measures (primary and secondary) were both strong and striking, particularly between WkMus and FIX).

6. Improvements in WkMus and FIX with each visit returned to within 10% of baseline values immediately prior to each subsequent visit.

These results uncovered several previously unreported phenomena that bear scrutiny and further research:

1. First and foremost, the orthotic devices that were provided were not truly custom-fitted to the 3-dimensional aspects of each patient’s foot. Instead, they were fabricated from the 2-dimensional patterns afforded by the use of the Associate scanning device. In addition, the actual orthotic devices were not truly custom fitted but rather came from a series of stock items which provided the closest match to the data obtained from the Associate. Furthermore, the sham insoles were puckered rather than flat and in many aspects bore a resemblance to the custom fitted devices, confounding the results. Although we polled our patients in both groups as to roughly what portion of the day they wore their orthotics, we did not match the groups as to how much time during their waking hours that they were actually on their feet with the orthotics in a load-bearing situation. Comparisons with a group not wearing insoles might have displayed differences not seen in this investigation.

2. Time constraints limited our sample size to 19 patients for each cohort, such that this investigation was only preliminary in nature and falling short of the 55 needed to obtain the 80% power needed to detect the minimal clinically significant effect of 6 points on the disability index.

3. We found a disturbing pattern of reversals of secondary outcome measures (the improvements in FIX and WkMus) produced by our manipulative treatments when patients returned for a subsequent treatment. These reversals immediately disappeared with the treatment, producing a sawtooth pattern. Overall, there was gradual improvement over the course of 5 treatments. What was not investigated was whether the primary outcome measures (VAS and RMS) decayed in a similar manner prior to each subsequent treatment.

4. We were unable to obtain high-resolution data on the foot scans produced on an earlier version of the Associate device from Foot Levelers. This meant that individuals with severe pronation problems, for example, were not detected or matched between groups. The previous trial was conducted for about a month to coincide with the availability of research personnel; however, the trends toward superiority of the custom fitted orthotic devices suggested that a more significant result would have been delivered with a longer study period.

5. Subjects in this trial were sometimes confused by the VAS scale, and sensitivity issues regarding the Roland-Morris Scale may have obscured some of the outcomes sought. Although our efforts at blinding patients as to whether they received the sham or custom fitted orthotics were shown to be successful, the price we may have paid was to have provided a contoured sham device that provided some comfort and satisfaction—as shown by the positive outcome measures in the sham cohort in the previous investigation.

6. The strong correlations in the outcome measures that we observed were dramatic and bear further study.

Reference

Select your language of interest to view the total content in your interested language
Post your comment

Share This Article

Recommended Conferences

Article Usage

  • Total views: 8033
  • [From(publication date):
    August-2016 - Dec 18, 2017]
  • Breakdown by view type
  • HTML page views : 7951
  • PDF downloads : 82
 

Post your comment

captcha   Reload  Can't read the image? click here to refresh

Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

Agri & Aquaculture Journals

Dr. Krish

[email protected]

1-702-714-7001Extn: 9040

Biochemistry Journals

Datta A

[email protected]

1-702-714-7001Extn: 9037

Business & Management Journals

Ronald

[email protected]

1-702-714-7001Extn: 9042

Chemistry Journals

Gabriel Shaw

[email protected]

1-702-714-7001Extn: 9040

Clinical Journals

Datta A

[email protected]

1-702-714-7001Extn: 9037

Engineering Journals

James Franklin

[email protected]

1-702-714-7001Extn: 9042

Food & Nutrition Journals

Katie Wilson

[email protected]

1-702-714-7001Extn: 9042

General Science

Andrea Jason

[email protected]

1-702-714-7001Extn: 9043

Genetics & Molecular Biology Journals

Anna Melissa

[email protected]

1-702-714-7001Extn: 9006

Immunology & Microbiology Journals

David Gorantl

[email protected]

1-702-714-7001Extn: 9014

Materials Science Journals

Rachle Green

[email protected]

1-702-714-7001Extn: 9039

Nursing & Health Care Journals

Stephanie Skinner

[email protected]

1-702-714-7001Extn: 9039

Medical Journals

Nimmi Anna

[email protected]

1-702-714-7001Extn: 9038

Neuroscience & Psychology Journals

Nathan T

[email protected]

1-702-714-7001Extn: 9041

Pharmaceutical Sciences Journals

Ann Jose

[email protected]

1-702-714-7001Extn: 9007

Social & Political Science Journals

Steve Harry

[email protected]

1-702-714-7001Extn: 9042

 
© 2008- 2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version