Make the best use of Scientific Research and information from our 700+ peer reviewed, Open Access Journals that operates with the help of 50,000+ Editorial Board Members and esteemed reviewers and 1000+ Scientific associations in Medical, Clinical, Pharmaceutical, Engineering, Technology and Management Fields.
Meet Inspiring Speakers and Experts at our 3000+ Global Conferenceseries Events with over 600+ Conferences, 1200+ Symposiums and 1200+ Workshops on Medical, Pharma, Engineering, Science, Technology and Business
All submissions of the EM system will be redirected to Online Manuscript Submission System. Authors are requested to submit articles directly to Online Manuscript Submission System of respective journal.

Acid production as a Limiting Factor during the Aerobic Biological PreTreatment of Confectionary Wastewaters

Christian Drakides* and Meiling Lay-Son
Hydrosciences Laboratory, Université Montpellier II, 34095 Montpellier cedex 05, France
Corresponding Author : Meiling Lay-Son
Hydrosciences Laboratory
Université Montpellier II
34095 Montpellier cedex 05, France
Tel: 33467143624
Fax: 33467144774
E-mail: [email protected]
Received January 11, 2013; Accepted May 22, 2013; Published June 02, 2013
Citation: Drakides C, Lay-Son M (2013) Acid production as a Limiting Factor during the Aerobic Biological Pre-Treatment of Confectionary Wastewaters. J Civil Environ Eng 3:128. doi:10.4172/2165-784X.1000128
Copyright: © 2013 Drakides C, et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

Visit for more related articles at Journal of Civil & Environmental Engineering

Abstract

The treatment of confectionary wastewaters by a biological aerobic treatment plant encountered strong failures when wastewaters concentration exceeded 30 g/l of chemical oxygen demand (COD), although the COD inlet flow remained under design specifications. Treatment performances stayed under 50%, and strong acid production and Hydrogen potential drop lead to heavy corrosion of equipments. During a laboratory scale study using the same organic load, with residence times ranging from 1 to 15 days, Hydrogen potential (pH) drop proved to be caused mainly by aerobic production of organic acids from sugars, leading thus to an auto-inhibiting process. The study demonstrated the influence of pH, acids and aeration rate upon key parameters as respiration rates and degradation kinetics. A reduction of 30 to 35 g/l of COD was obtained in laboratory scale reactors with pH and oxygen control. A comparison between the laboratory scale reactors and the full scale plant was made by measuring in the reactors the clean water oxygenation transfer rates and comparing its values to the data issuing from the plant. Compared to the data issuing from the full-scale wastewater treatment plant, the results of this study allowed giving recommendations for its upgrade.

Keywords
Biological treatment; Chemical oxygen demand; Confectionary wastewaters; Organic acids; Oxygenation transfer rates; pH
Introduction
Wastewater concentration in confectionary factories may vary widely depending upon the products and the processes. As the main stream of wastewater issues from the washings, a consequence of water savings policies is the production of a relatively small volume of wastewater with a high organic content (primarily sugars). This high organic content is represented by high levels of chemical Oxygen demand (COD) and biological oxygen demand (BOD). Consequently, this wastewater is normally easily amenable to biological degradation if the required nutrients are added in proportion to the concentrations of the wastewater organic compounds [1].
Among the aerobic biological wastewater treatment processes the most commonly used is the activated sludge one [2]. If the treated water can be discharged to an existing domestic sewer connected to a wastewater treatment plants facility (WWTP), an aerobic high-rate pre-treatment may be chosen to avoid the investment in a separate complete WWTP and to minimize operation costs. In the present confectionary wastewater treatment case, a COD volumetric load of 6 kg COD/m3/d was designed to obtain a COD degradation rate limited to 70%, normally allowing the discharge of the pre-treated effluent to the sewer. The maximum corresponding allowed concentrations were of 61 g/l for the influent and of 18.75 g/l for the effluent. Nevertheless, after a few months of operation, the pH in the tanks fell under 4.8 units and performances under 50%. After one year, the aeration equipments and tanks were out of work because of corrosion, and the WWTP was emptied.
Although the inhibition of anaerobic methanisation by acetate has been described early [3], little information has been published concerning acetate or volatile fatty acids (VFA) inhibition during aerobic processes. Considering this latter parameter, Adamse [4] studied the effect of aeration rate and pH on response of dairy waste activated sludge, Orhon et al. [1] the biological treatability of confectionary wastewaters by respirometric techniques, Ugwanyi et al. [5] the inhibition of thermophilic aerobic treatment of agricultural wastes, and De Anda et al. [6] the efficiency of protein production with E. coli.
In aerobic processes, oxygen transfer is often the rate-limiting step for the degradation kinetics, due to the low solubility of oxygen in aqueous solutions, and the correct determination of operational parameters is a crucial step in the design, operation and scale-up of bioreactors [7,8].
This paper reports a laboratory study of the biological pretreatment of these high strength confectionary wastewaters by means of a high-load activated sludge process. Design parameters have been determined, and their effects upon pH, aeration rate and VFA production have been discussed.
Materials and Methods
Experimental setup
Experiments were carried out in laboratory using two reactors, each consisting of a highly mixed aerated tank connected to a clarifier. Each reactor was equipped with two peristaltic pumps, one for feeding wastewater and one for recycling sludge from the clarifier, and with a variable number of aerators and air pumps. Reactor 1 had a 3 L tank volume and reactor 2 had a 6 L volume.
Reactor hydraulics was close to perfect mixing, and effluent concentration represented the concentration in aeration tanks.
Temperature was maintained at 25 ± 0.5°C for the two reactors, pH was monitored and adjusted in the reactors by NaOH or HCl addition, and dissolved oxygen was measured daily.
Mean water residence time (MWRT) was calculated measuring the daily outlet flow, and was kept between 1 and 15 days.
For each parameter condition set, an adaptation time of at least three times the current residence time was allowed before analytical results were considered representative of steady-state conditions.
Operational procedure
The feed wastewater was recuperated once monthly directly from a confectionary WWTP (HARIBO Uzes, France). This wastewater is characterized by high levels of sugars. The characteristics of the influent were variable along time, as the sugars were rapidly transformed in ethanol and acetic acid under storage conditions. Consequently, wastewater was keep freezed at -18°C until feeding the reactors, to preserve its initial characteristics. Table 1 shows the concentrations range for the influent fed to the reactors (most of time undiluted).
Feeding was divided in eight batches per day, one every three hours, to represent the wastewaters treatment plant (WWTP) conditions, where wastewaters are collected in a tank in the confectionary and pumped to the WWTP once this tank is full.
Each reactor was inoculated initially with sludge collected from the confectionary WWTP.
The same operational conditions were tested in the reactors, which differed mainly with their aeration conditions.
MWRTs were gradually reduced at the end of experiments from 10 days to 1, diluting the effluent proportionally to the inverse of residence time. This allowed the reactors to work at a nearly constant organic load (0.6 to 1.4g COD/gMLSS/d), whereas varying actual COD concentrations in the reactors (suspended solids of pilot mixed liquor were kept around 5 g/l value, close to WWTP values).
The effect of pH upon respiration and degradation kinetics was studied using the respirometric method by measuring the oxygen uptake as indicator of biodegradation. This method is described in 4.4.
Oxygenation rates were adjusted by varying the number of air pumps and porous diffusers in the tanks.
Analytical methods
Influent and effluent samples were filtered through 0.2 um cellulose acetate filters (Sartorius stedim, Germany) and preserved by sodium azide (2.5 mM) before analyses of sugars (glucose, fructose and sucrose) and organic acids (acetic, lactic, propionic, etc).
Glucose, fructose and sucrose concentrations were determined using high-performance anion exchange chromatography (HPAEC), on a Carbopac PA-1 analytical column (4×250 mm). Detection was performed with a pulsed amperometric ED50 detector (Dionex Corp., Sunnyvale, CA). Twenty five microliters of sample were injected. Each carbohydrate concentration was established after integration of respective areas (Chromeleon management system (Dionex)) and comparison with standard curves obtained with all relevant sugar standards (Sigma). The elution was achieved isocratically with 18 mM NaOH at a flow rate of 1 ml/min.
Organic acids were analysed by high-performance liquid chromatography (HPLC) upon centrifuged (10 min, 10,000 g at 4°C) and deproteinized samples. Protein removal was carried out using Ba(OH)2-ZnSO4,7H2O method of Slein. The HPLC system (Agilent 1100, Agilent Technology) was fitted with two columns (Resex ROA 300 × 7.8 mm, Phenomenex) mounted in serial assembly in an oven thermostated at 50°C. Columns were eluted at 0.7 mL/min by a solution of 2 mM H2SO4 in ultra pure water. A refractometer (RID G1362A) was used as detector.
Acetic and lactic acids were also measured using specific enzymatic test kits (Megazyme, Ireland).
Total acidity, expressed under acetic acid which was the largely dominant form, was measured by acid-base titration. Additionally, the computational program CURTIPOT1, was used to generate potentiometric titration curves for the parameter set chosen in each simulation, allowing to take into account the other acid-base constituents of the waters.
COD was measured using a photometric method for small-sample rapid dichromate oxidation (HACH DR2010 spectrophotometer and digester, and COD Vials CHEMetrics reagent).
Mixed liquor total suspended solids (MLSS) in the reactors were measured by filtration through Whatman GF/C filters followed by drying and weighing with a Precisa 410 AM-FR balance.
pH and Dissolved oxygen concentration (DO) were measured daily in the reactors using pH meters (EUTECH Instruments, IQ Scientific Instruments) and standard DO meters (WTW Microprocessor Oximeter, Ponselle O2W).
(Note: special care had to be given to Oxygen and pH probes choice and maintenance. High organic acids and sulfid-riche proteins concentrations leaded to rapid and irreversible probes deterioration and to high measurement errors with some Oxygen probes too sensitive to undissociated organic acids interference)
Respirometry
Respirometric techniques were used in preliminary experiments for the evaluation of the influence of pH on the degradation kinetics through estimation of Vmax and KM Michaelis-Menten constants. Batch reactors containing 250 ml volume of mixed liquor sampled in the reactors were saturated with air and DO consumption followed using the same standard probes used to monitor DO in the reactors. Temperature was maintained at 20 ± 0.5°C. Specific Oxygen uptake rate (SPOUR) was calculated by dividing the slope of the best-fit regression line of the DO decrease along time by the MLSS measured of each sample. pH and initial concentrations of added substrates (sugars or acids) were fixed for each experiment.
Assessment of oxygenation rates (kLa)
In order to study the effect of aeration on sugars and acids degradation kinetics, the volumetric Oxygen mass transfer coefficients (kLa) of the reactors were measured for aeration configurations differing by the number of air diffusers and the volumetric airflow. These configurations allowed the pilot plants to work with measured kLa values ranging from 1.5×10-3/s to 9.8×10-3/s.
Determination of kLa in the reactors was necessary to quantify aeration efficiency and to evaluate the effects of the operating variables on the actual supply of dissolved Oxygen to the MLSS bacteria. Mass balance for the dissolved oxygen in a well-mixed liquid phase can be established, in the absence of biomass or with non-respiring cells, as Equation 1:
image (1)
where dC/dt is the accumulation Oxygen rate in the liquid phase, C the actual oxygen concentration and Cs the saturation concentration.
In this study, the kLa values for the different configurations were determined using the method described by Déronzier et al. [7], or sodium sulfite addition method in the aeration tank under standard conditions, i.e. reactors filled with clean (tap) water, no biomass, initial DO = 0 mg/l. The Oxygen transfer estimation was based on the measurement of dissolved oxygen concentration in the liquid during the absorption of oxygen in the solution. DO increase under constant aeration was monitored using two standard dissolved O2 probes [9].
The kLa was then calculated from the obtained regression curve using a least-squares approximation method written under EXCEL®.
One main shortcut of the kLa determination method is that the measure is done using tap water, and the result reported to reference conditions (DO of 0 mg/l, T° of 10°C). During real wastewater treatment, presence of biomass and soluble compounds may strongly affect the dissolution of Oxygen, lowering the kLa by an unknown factor (alpha), often estimated around 0.7 [3]. But here, high concentrations of sugars, acids and proteins may have much more incidence and the standard kLa cannot be extrapolated to real conditions. Nevertheless, as laboratory experiments were conducted with the same wastewaters and in the same conditions of pH and T° as in real installations, the clean water kLa found in the laboratory can be usefully compared with the data given by the furnishers of the industrial aeration equipment and also obtained using tap water assays.
Once known the kLa, the Oxygen transfert rate (OTR) in clean water for a given Oxygen concentration C can be estimated through equation 2:
OTR = kLa*(Cs-C) (2)
Under constant kLa conditions, OTR is compensed by biological respiration and any variation of biological activity leads to a variation of the measured C, which comes as a good indicator of activity or inhibition.
As the same substrate and saline concentrations, temperature or pH were used in the pilots as well as in the real plant, the measured DO in the pilots may be used to characterize the aerating conditions leading to acids production or degradation, and by comparing the OTR values measured in the pilots and given for the real plant, to characterize the aerating conditions prevailing in the real plant and their influence upon treatment inhibition.
Kinetic models
The Michaelis-Menten equation (Equation 3) is typically used to represent degradation kinetics when a substrate is not inhibitory for the enzymatic activity [2,10,3]. It was used here to represent the sugars and acid degradation rates and also the respiration rates in the presence of pure glucose and a mixture of sugars.
image (3)
Where Vmax is the maximum velocity of the enzyme process, Ks the Michaelis-Menten constant, dS/dt the degradation rate of the substrate, dP/dt the formation rate of the product and S the concentration of substrate.
Parameter optimisation was made for Vmax and Ks with a leastsquares method to allow a best fit of the kinetic model to experimental data.
Results and Discussion
The activated sludge reactors follow-up was carried on five hundred ten days. Preliminary studies were made to determinate the influence of pH upon degradation kinetics and the optimal pH interval.
Inhibition caused by extreme pH values
When the graph was plotted of the SPOUR measured for the mixed liquor of the reactors versus pH, the SPOUR never fall to low values for pH ranging from 5.5 to 6.5 units. Inhibition occurred frequently under pH value of 5.7, and less frequently over pH value of 6.5 (Figure1).
This result was confirmed by pH and DOES monitoring of the two reactors. A plot of these two parameters shows that with a constant aeration rate, DO fall to values close of 0 mg/l only for pH values ranging from 6 to 7.5, indicating high respiratory activity of the MLSS bacteria. It was therefore concluded that values of pH less than 5 or 6 (according to the pilot aeration) or greater than 8 led to respiratory inhibition and DO increase (Figure 2).
Respirometric evaluation and kinetic coefficients
SPOUR measurement was also made using the mixed liquor from pilot plants and known added concentrations of mixture of sugars and pure glucose to evaluate the respiratory rate. Results are shown figures 3 and Figure 4.
a) Substrate: 50% glucose and 50% sucrose, pH=5.5
The Michaelis-Menten equation was used as mentioned above. For this experiment, the best adjusted parameters were found to be Ks=1.58 g/l and Vmax= 0.046 mg O2/ min/ gMLSS.
b) substrate: 100% glucose, pH = 5.8
The same adjustment of a Michaelis-Menten equation gaves values of Vmax = 0.101 mg O2/g MLSS/min and Ks = 1.230 g/l glucose (Figure 4).
Kinetics of COD degradation: influence of aeration rates
During the first periods of reactors follow-up and even with pH correction, high degradation rates were obtained only when the influent contained less than 30 g/l of COD. Consequently, the effect of aeration rate was suspected. Adamse et al. [4], showed that with dairy waste activated sludge, high aeration rates did not prevent the pH decrease obtained when high substrate concentration was imposed. However, restoring of the pH to its initial values was accelerated at high aeration rates. Thereafter, aeration rates were increased in the reactors and different influent concentrations from 50 to 80 g/l of COD were tested, but steady-state COD elimination stayed almost constant, around 30 g/l of COD. The kLa values obtained for the different aeration configurations tested ranged from 1.5 x10-3/s to 9.8 x10-3/s (Table 2).
COD degradation kinetics were also determined during the same periods using the pilots follow-up data. For each steady-state period and under given aeration conditions, obtained COD degradation rates (as g/l of COD eliminated/g MLLS/h) were expressed, and converted into concentrations that could be eliminated in the real WWTP assuming the same aeration and MWRT conditions Table 2.
For the two reactors, the COD degradation rate increased with increasing aeration rate. MWRT had no clear effect in a large interval, at least for reactor 2 which was more aerated than reactor 1. The degradable COD concentration of the influent did never exceed 35 g/l, corresponding to a maximum allowable influent concentration of no more than 50 g/l.
The corresponding Oxygen transfer rate (OTR) in clean water was evaluated to 0.08 mgO2/s/l for the optimum conditions of oxygenation that was near from the 0.1 - 0.14 OTR value range given for the full scale WWTP aerator.
Residual substrate concentration
In order to check the degradable fraction of the influent COD, the COD obtained in the reactors was plotted against measured acids concentrations. A linear regression correlation was found for each reactor:
Reactor 1: COD = 1.26 x Acids concentration + 4.2 r2=0.85
Reactor 2: COD = 1.17 x Acids concentration + 6.4 r2=0.54
These relations indicated that the treated wastewater presented a residual substrate concentration containing acids but also another organic fraction. This later can be associated to the protein fraction of the effluent that undergoes decomposition more slowly than the sugars [4]. The residence time used in this experiment was may be too short to obtain a good degradation of complex proteins. The higher activity obtained with reactor 2 led also to a less linear correlation.
Production of organic acids intermediates
When the reactors were fed with confectionary wastewater (batch feeding, as mentioned in Operational Procedure) DO dropped sharply after feeding and pH dropped more slowly (Figure 5).
The pH drop during the degradation of the carbohydrate fraction was caused by transitory accumulation of acid intermediates (mainly acetic, propanoic and butanoic) that were detected by HPLC and titration. This result was in accordance with those of Adamse [4] and Caunt et al. [11]. In addition, appreciable amounts of propanoic and butanoic acids were found here, accompanied by traces of pentanoic and isobutanoic acids (Figure 6).
As can be seen in Table 3, the concentration of residual organic acids increases strongly when aeration decreases, as expected. Surprisingly, at the same loading rate and dissolved oxygen concentration, a diminution of residence time in the reactor improves degradation performances, which result is in contradiction with the usual kinetics. This may be explained considering that keeping the load constant while decreasing the residence time is only possible through a dilution of the effluent, thus lowering the concentrations of sugars and acids intermediates. Acetic acid has already been reported to inhibit microorganisms activity when highly concentrated [3,12-14], because of pH inhibition or of unionized acetate inhibition [3,15]. Here, inhibition seemed to increase with the acid concentration, and to decrease with the availability of Oxygen.
Degradation rates evaluation
The values of kinetic parameters obtained by adjustement to a Michaelis- Menten equation are summarized in Table 4. So, it can be concluded that under the high loads encountered in this study, sugars are readily transformed into acids intermediates that are released in the solution. The degradation rate for the acids being lower than their production rate, their concentration increases up to the point where the pH drop induces inhibition of the process. A comparison of the Vmax value for the sugars degradation and the Vmax value for Oxygen respiration in the presence of sugars found above (max. 0.1 mg O2gMLSS-1 .min-1 = 6 mg O2/gMLSS-1 .h-1) confirms that direct acid production from sugars is a mechanism that proceeds with a low Oxygen consumption.
Conclusions
Although powerful aeration equipments may be used, the high load aerobic pretreatment of highly concentrated confectionary wastewaters may create very low pH conditions leading altogether to a decrease of COD degradation rate and severe damages to the plants.
This study demonstrated that in these conditions, a high uncontrolled production of organic acids intermediates by bacteria (mainly acetic acid but also others) occurred even with high aeration rates. The degradation rates of these acids being smaller than their production rates, their accumulation lead to the observed pH drop and to the further degradation inhibition and high COD residual. Classical degradation kinetics based solely upon MWRT and substrate concentration is unable to represent this phenomenon and cannot be used for the design of such WWTP.
As physico-chemical conditions were similar, a comparison between the laboratory scale pilots and the full scale plant was made by measuring in the pilots the clean water OTR and comparing its values to the values given for the WWTP.
Once this assessment done, the physico-chemical and kinetics data issuing from the study were compared to those obtained from the actual WWTP. This allowed to give the following recommendations for industrial scale-up:
1. the WWTP OTR value allows to obtain the same performances as our laboratory scale reactor, i.e. a reduction of 30 to 35 g COD per liter, but not to obtain an effluent in accordance with the emission standards when the influent concentration exceed 50 g/l of COD. Any increase in OTR value would be useless as this does not increases the COD reduction.
2. keeping the pH of the aeration tank between 5 and 6 (around 5.5) units by using NaOH addition and keeping influent concentrations at no more than 45 g/l COD, the existing aeration facilities, once properly protected against corrosion, would allow to obtain effluent concentrations complying with the maximum allowed value of 15 g/l COD for the outlet flow to the sewer.
Acknowledgements
This work was supported by CNRS/HARIBO Inc. Research Collaboration Agreement n° CT063051s.
References

Tables and Figures at a glance

Table icon Table icon Table icon
Table 1 Table 2 Table 3

 

Figures at a glance

 

Figure Figure Figure
Figure 1 Figure 2 Figure 3
Figure Figure Figure
Figure 4 Figure 5 Figure 6
Select your language of interest to view the total content in your interested language
Post your comment

Share This Article

Relevant Topics

Article Usage

  • Total views: 11951
  • [From(publication date):
    September-2013 - Aug 24, 2019]
  • Breakdown by view type
  • HTML page views : 8139
  • PDF downloads : 3812
Top