Make the best use of Scientific Research and information from our 700+ peer reviewed, Open Access Journals that operates with the help of 50,000+ Editorial Board Members and esteemed reviewers and 1000+ Scientific associations in Medical, Clinical, Pharmaceutical, Engineering, Technology and Management Fields.
Meet Inspiring Speakers and Experts at our 3000+ Global Conferenceseries Events with over 600+ Conferences, 1200+ Symposiums and 1200+ Workshops on
Medical, Pharma, Engineering, Science, Technology and Business

Bioeffects of Transient and Low-Intensity Ultrasound on Nanoparticles for a Safe and Efficient DNA Delivery

Mei Fen Shih1, Chung Huang Wu2 and Jong Yuh Cherng3*

1Department of pharmacy, Chia-Nan University of Pharmacy and Science, 60 Erh-Jen Rd., Sec 1, Jen-Te, Taiwan

2Medical Equipment Maintenance Office, Songshan Armed Forces General Hospital, Taipei, Taiwan

3Department of Chemistry and Biochemistry, National Chung Cheng University, 168 University Rd., Chia-Yi, Taiwan

*Corresponding Author:
Dr. Jong Yuh Cherng
Department of Chemistry and Biochemistry
National Chung Cheng University, 168 University Rd
Chia-Yi, Taiwan
E-mail: [email protected]

Received Date: July 14, 2011; Accepted Date: August 23, 2011; Published Date: August 25, 2011

Citation: Shih MF, Wu CH, Cherng JY (2011) Bioeffects of Transient and Low- Intensity Ultrasound on Nanoparticles for a Safe and Efficient DNA Delivery. J Nanomedic Nanotechnol 6:276. doi:10.4172/2157-7439.1000276

Copyright: © 2011 Shih MF, et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

Visit for more related articles at Journal of Nanomedicine & Nanotechnology

Abstract

An important advantage of polymer-based gene delivery systems over viral transfection systems is that transient gene expression without the safety concerns can be achieved. In addition to the polymeric systems to deliver DNA, therapeutic ultrasound is potentially useful because ultrasound energy can be transmitted through the body without damaging tissues and could be applied on a restricted area where the desired DNA is to be expressed. In this study, bioeffects of ultrasound on the transfection efficiency and cytotoxicity of DNA-polymer complexes on mammalian cells (HEK-293 and COS-7 cell lines) were investigated.

Polymer-DNA ratios for optimal transfection efficiency and the size of PEI/DNA or PDMAEMA/DNA complexes were found not affected by ultrasound treatment. Also, electrophoresis results indicate that the tertiary DNA structure was not influenced by ultrasound when exposed up to 10 seconds. More importantly, cationic polymer-mediated cell transfection was significantly enhanced and reached a 150% increase by using ultrasound. Cytotoxicity of HEK-293 and COS-7 cell lines was not observed after ultrasound. Therefore, these results indicate that clinical applications of ultrasound could be used as a safe and efficient method for non-viral gene delivery

Keywords

Transfection; Polymer-DNA complexes; Ultrasound; Cytotoxicity

Introduction

Ultrasound has evolved from being primarily used for diagnosis into treatment of diseases (e.g. cancer) by delivery of drugs, proteins (interleukins, antibodies) or nucleic acids (DNA, siRNA) to the site of diseases [1-6]. Rapid and efficient transfer of therapeutic agents is a critical first step in therapy and mild or no cytotoxicity is a favorable step after treatment. In gene transfection, non-viral/physical in-vitro techniques are commonly used to mediate gene transfer and transgene expression with a varying degree of efficiency including liposome/ polymer-mediated gene transfer [7,8]. The use of ultrasound in a combination with these techniques improves transfection efficiency and site specificity [9]. Ultrasound can also increase the permeability of cell membrane to macromolecules such as plasmid DNA. Enhancement of gene expression was then observed by irradiating ultrasonic wave to the tissue after injection of DNA [10]. However, reduced cell viability in vitro and in vivo was reported because of possible acoustic pressure or ultrasound-caused cavitation [11]. Low-intensity pulsed ultrasound, transmitting as an acoustic pressure wave and applying mechanical stress indirectly to the tissues, has been reported to promote osteogenesis and protein synthesis, calcium uptake, and DNA synthesis in different cells and this ultrasound application is flexible and safe for use in gene delivery applications [12].

equation

It was reported that a combination of microbubbles with ultrasound could further increase the gene expression level in tumor tissues or tendons [13,14]. This is because the microbubbles (could be a few μm in size) with a thin shell such as albumin are more stable compared to air bubbles (conventional sonoporation) [15]. Although microbubbles demonstrated an ultrasound-targeted capability [16], a high power pulse is required to destroy the microbubbles so concerns over cytotoxicity or irreversible damage remain [15,17].

In this study, we use a transient and low-intensity ultrasound to enhance the delivery of complexes of DNA with two polymers (PEI and PDMAEMA). The exposure time of ultrasound is 10 seconds with 9 cycles (separated by an interval of 230 seconds). We hypothesize that the procedure would minimize cytotoxicity without compromising the increase of transfection efficiency. Also, these polymer-DNA complexes are stable with sizes smaller than 0.2 μm. Comparing to microbubbles commonly present with a size around 1-8 μm [15,18], their stability and vascular damage are major determinants of in vivo efficacy [19,20].

Experimental

Chemicals

Luria broth (LB) and o-Nitrophenyl-β-D-Galactopyranoside (ONPG) were purchased from Sigma. 3’-[1-(phenylaminocarbonyl)- 3,4-tetrazolium]-bis (4-methoxy-6-nitro) benzene sulfonic acid hydrate (XTT assay kit) was obtained from Roche. Agarose and restriction enzyme KpnI (10U/μl) were purchased from Invitrogen. Polyethyleneimine (PEI, Mw=25 kDa) was from Aldrich and Poly(2- (dimethylamino)ethyl methacrylate) (PDMAEMA, Mw=130 kDa) was synthesized and purified as described previously [21]. Dulbecco’s modified Eagle medium (DMEM) supplemented with 10000U/ml Penicillin and 10mg/ml streptomycin for HEK-293 cell line (CCRC 60019) and COS-7 (CCRC 60094) which were obtained from Food Industry Research & Development Institute (Taiwan).

Plasmid DNA

Plasmid (pCMV lacZ), which encodes the lacZ gene for β-galactosidase, was driven by a SV40 promoter to gene expression. Plasmid DNA was amplified in E coli (grown in LB medium with 50μg/ ml of ampicillin) and purified by column chromatography (QIAGENMega kit). The purity of plasmid DNA was determined by a UV Spectrometer at 260/280 nm with a ratio higher than 1.80. Agarose (0.7%) gel electrophoresis analysis using restriction enzyme (Kpn I) showed that plasmid DNA was mainly in a supercoiled form.

Preparation of polymer-based DNA delivery systems

Plasmid DNA (with a final concentration of 5μg/ml) was prepared in plain DMEM. PEI and PDMAEMA were prepared in plain DMEM and various ratios of polymer/DNA (0.5/1, 1/1, 2/1, 3/1, 5/1) were reached by adding the polymer into DNA. DNA/polymer complexes were then formed after 30 minutes prior to transfection

Ultrasound treatment

Low-intensity pulsed ultrasound (1.5~2.2 MHz, 3W/cm2, Neo- Tec N101, NeoAsia Enterprise, Taiwan) was used. The ultrasound was delivered in a form of square waves and transmitted by a 36mm flat-top probe. The 96-well plates were divided into 24 areas to apply ultrasound treatment. In order to minimize the effect of raising temperature from ultrasound, each area was treated for 10 sec before moving to the next area. Each area was treated with an upward-direction ultrasound for a total of 9 cycles (interval = 230 seconds/cycle) from bottom of culture plates (see diaphragm 1). The tertiary structure of plasmid DNA was examined after ultrasound treatment. Plasmid DNA was either treated with a ultrasonic cleaner with high power (40 KHz, 140W, WUCD06H, Double eagle enterprise, Taiwan) for 10 sec, 1min, 3 min, 10 min, and 20 min or lower power (3W/cm2; 30W in total from a 36 mm probe) for 90 sec or 30 min prior to electrophoresis analysis

Cell cultures

HEK-293 and COS-7 cell lines were used to evaluate the effectiveness of ultrasound on transfection efficiency. The HEK-293 cell line was cultured in completed DMEM culture medium (from Sigma), containing 10% inactivated horse serum (from HyClone), 1mM sodium pyruvate (from Sigma), and 100U/ml penicillin-100μg/ ml streptomycin (from Invitrogen). The COS-7 cell line was cultured in completed DMEM culture medium, containing 5% inactivated FBS (from HyClone), 1mM sodium pyruvate, 25mM Hepes (from Sigma), and 100U/ml penicillin-100U/ml streptomycin-100μg/ ml amphotericin (from Invitrogen). Both cells were cultured in an incubator (Sanyo MCO-17AIC) at 37oC and 5% CO2.

In vitro transfection

Cells were seeded into a 96-well plate at a density of 1x104cells/ well and grown overnight (with 70-80% confluence) at 37oC and 5% CO2. Prior to transfection, cells were rinsed with plain DMEM to avoid FBS interference. 200μl of polymer/DNA complexes was added to each well and incubated for 1 hour. Ultrasound treatment was carried out with a low intensity (3W/cm2, 90 sec in total divided in 9 cycles; that is 10 sec/cycle with an interval of 230 sec) and then incubated at 37oC and 5% CO2 for further 30 minutes. After incubation, the polymer/ DNA complex was removed by aspiration and the each well was refilled with 100μl of completed DMEM culture medium. After 48 hours, transfection efficiency was determined by β-galactosidase gene expression. Briefly, cells were washed once with PBS prior to adding 20μl lysis buffer (PH 8.0, contains 0.5mM tris base, 1.5mM NaCl and 1% triton X) per well and incubating at 4°C for 20 min. After that, 180μl of ONPG staining solution (0.09M sodium phosphate, PH 7.5, 0.9mM MgCl2, 0.67 mg/ml ONPG) was added into each well and incubated at 37°C and 5% CO2 for 60 minutes. The absorbance was determined at 405/630nm using an ELISA plate reader (Labsystems Multiskan MS).

Cell viability of transfected cells

To determine the influence of ultrasound on cell viability, the number of viable cells was measured using an XTT colorimetric assay according to the manufacture protocol from Roche, Taiwan. Briefly, mixing 5ml of XTT stock solution and 100μl of electron-coupling reagent prior to the assay. 50μl of the XTT mixture was added to each well and incubated for 60 min at 37°C and 5% CO2. The absorbance was determined at 490/690nm using an ELISA plate reader (Labsystems Multiskan MS).

Statistical analysis

Data of replicates from each group of six samples were combined from at least three different experiments. A two-tailed student’s unpaired test was used to compare the mean values of two populations with respect to a significant difference in transfection efficiency and cytotoxicity (GraphPad Prism 3.0 software).

Results

Effects of ultrasound on plasmid DNA tertiary structures and sizes of polymer-DNA complexes

Plasmid DNA was initially in supercoiled topology (Figure 1, lane 1). After 10 sec exposure of a high power (140W) ultrasound, the amount of DNA was reduced (lane 3). The reduced DNA was not converted to a linear form which should be visible as shown in lane 2 but was degraded into small fragments (shown as a smear pattern, lane 3-5). The DNA was degraded more under 140W ultrasound as the treatment time was increased (from 1 min, to 20 min; lane 4 and lane 7, respectively). Conversely, a low power (30W; 3W/cm2 from 36- mm probe) ultrasound appeared not to affect the integrity of DNA in either 90 sec or 30 min treatment group (Figure 2; lane 2 and lane 3, respectively). The sizes of PEI-DNA and PDMAEMA-DNA complexes were not affected either by a low power (30W) or a high power (140W) ultrasound (data not shown).

nanomedicine-nanotechnology-ultrasound-plasmid-enzyme

Figure 1: Effects of a high power (140W) ultrasound on DNA tertiary structures. Lane 1: control plasmid DNA, Lane 2: plasmid DNA treated with KpnI restriction enzyme, Lane 3-7: plasmid DNA treated with the ultrasound for 10 sec, 1min, 3 min, 10 min, and 20 min.

nanomedicine-nanotechnology-frequency-transducer-ultrasound

Figure 2: Effects of a low frequency (30W; 3W/cm2 from 36mm transducer) ultrasound treatment on plasmid DNA tertiary structures. Lane 1: control plasmid DNA, Lane 2-3: plasmid DNA was treated with the ultrasound treatment for 90 sec, and 30 min, Lane 4: plasmid DNA was treated with KpnI restriction enzyme.

Bioeffects of ultrasound on COS-7 cells

PEI/DNA complexes:In transfection efficiency studies with PEI and COS-7 cells, the optimal transfection ratio for PEI-DNA complexes without ultrasound treatment (control) was 1/1 (w/w) (Figure 3A). As we have shown previously [21], a lower ratio (e.g. PEI-DNA ratio =0.5/1) increased the particle size of complexes over 0.3 µm and a high ratio (e.g. PEI-DNA ratio>2/1) also increased their cytotoxicity. Both circumstances would result in decreased transfection efficiency.

nanomedicine-nanotechnology-ultrasound-transfection-efficiency

Figure 3A: Effects of the ultrasound treatment on transfection efficiency of PEI-DNA complexes at various ratios. Cells were treated with PEI-DNA complexes and ultrasound or without (normal group) a low energy ultrasound for 10 sec and 9 cycles. Values are expressed as Mean ± SD in triple experiments. Statistics are shown for cells treated with ultrasound (p<0.01) compared to controls.

Exposure to ultrasound (10 sec, 9 cycles with 230 sec interval) increased transfection efficiency (Figure 3A, p<0.01) for PEI/DNA complexes at 1/1 ratio. For other ratios of PEI/DNA, no significant increase in transfection efficiency was observed before and after the ultrasound exposure. In Figure 3B, there is a slight decrease in cell viability of PEI/DNA complexes on COS-7 cells at higher polymer- DNA ratios (from 2/1 to 5/1). This decrease was due to the effect of cationic polymers upon cells which is well documented [22]. Importantly, ultrasound treatment did not cause any cytotoxicity under our test conditions when compared to controls.

nanomedicine-nanotechnology-ultrasound-treatment-cytotoxicity

Figure 3B: Effects of the ultrasound treatment on cytotoxicity in PEI-DNA complexes at various ratios. Cells were treated with PEI-DNA complexes and ultrasound or without (normal group) a low energy ultrasound for 10 sec and 9 cycles. Values are expressed as Mean ± SD in triple experiments.

PDMAEMA/DNA complexes:The optimal ratio of PDMAEMA/ DNA complexes for transfection was determined to be at 5/1 (w/w) (Figure 4A). Further higher polymer/DNA ratios would result in significant cytotoxicity. However, for lower ratios (from 0.5/1 to 2/1), particle sizes of complexes were observed over 0.3 µm and were the cause of lower transfection efficiency [21] compared to the size of complexes at 3/1 or 5/1 was 0.2 µm and 0.15 µm, respectively. After ultrasound treatments, a 150 % increase in transfection efficiency was found in the complexes at ratios of 3/1 and 5/1 with small sizes (<0.2 µm). In contrast, the transfection efficiency of complexes at 2/1 with a larger size (0.3 µm) did not show a beneficial effect on increasing gene transfer. Again, the ultrasound treatment did not induce more cytotoxicity in comparison with controls (without ultrasound) (Figure 3B).

nanomedicine-nanotechnology-ultrasound-complexes-efficiency

Figure 4A: Effects of the ultrasound treatment on transfection efficiency of PDMAEMA-DNA complexes at various ratios. Cells were treated with PDMAEMA-DNA complexes and ultrasound or without (normal group) a low energy ultrasound for 10 sec and 9 cycles. Values are expressed as Mean ± SD in triple experiments. Statistics are shown for cells treated with ultrasound compared to untreated cells at ratios of 5/1 (p<0.01), 3/1 (p<0.05) and 2/1 (NS; not statistically different).

nanomedicine-nanotechnology-ultrasound-cytotoxicity-ratios

Figure 4B: Effects of the ultrasound treatment on cytotoxicity of PDMAEMA-DNA complexes at various ratios. Cells were treated with PDMAEMA-DNA complexes and ultrasound or without (normal group) a low energy ultrasound for 10 sec and 9 cycles. Values are expressed as Mean ± SD in triple experiments.

Bioeffects of ultrasound on 293 cells

PEI/DNA complexes: Similar transfection results were obtained in the use of PEI-DNA complexes on 293 cells compared to COS-7 cells. As in the experiment with COS cells, a significant increase in transfection efficiency at a 1/1 ratio of PEI-DNA complexes was found (Figure 5A, p<0.05) after the ultrasound treatment. Again, no additional cytotoxicity was observed from our test conditions with ultrasound (Figure 5B).

nanomedicine-nanotechnology-ultrasound-transfection-efficiency

Figure 5A: Effects of the ultrasound treatment on transfection efficiency of PEI-DNA complexes at various ratios. Cells were treated with PEI-DNA complexes and ultrasound or without (normal group) a low energy ultrasound for 10 sec and 9 cycles. Values are expressed as Mean ± SD in triple experiments. Statistics are shown for cells treated with ultrasound (p<0.05) compared to controls.

nanomedicine-nanotechnology-ultrasound-treatment-cytotoxicity

Figure 5B: Effects of ultrasound treatment on the cytotoxicity of PEI-DNA complexes at various ratios. Cells were treated with PEI-DNA complexes and employ ultrasound or without (normal) a low energy ultrasound for 10 sec and 9 cycles. Values are expressed as Mean ± SD. Triple experiments were performed.

PDMAEMA/DNA complexes: In agreement with the findings of PDMAEMA-DNA complexes on COS cells, PDMAEMA-DNA complexes were optimally transfected at a ratio of 5/1 followed by ratios of 3/1, 2/1, 1/1, and 0.5/1 (Figure 6A). After ultrasound treatment, a 140% increase in transfection efficiency was observed for the 3/1 and 5/1 ratios (Figure 6A, p<0.05). When larger PDMAEMA-DNA complexes were used (ex. at 2/1 ratio), ultrasound did not improve transfection efficiency (no statistical difference from control). Moreover, cell viability of 293 cells treated with PDMAEMA/DNA complexes was not influenced by ultrasound treatment (Figure 6B) which suggests that this is a safe and effective method to improve gene transfer.

nanomedicine-nanotechnology-ultrasound-treatment-transfection

Figure 6A: Effects of the ultrasound treatment on transfection efficiency of PDMAEMA-DNA complexes at various ratios. Cells were treated with PDMAEMA-DNA complexes and ultrasound or without (normal) a low energy ultrasound for 10 sec and 9 cycles. Values are expressed as Mean ± SD in triple experiments. Statistics are shown for cells treated with ultrasound compared to untreated cells at ratio of 5/1 (p<0.05), 3/1 (p<0.05) and 2/1 (NS).

nanomedicine-nanotechnology-treatment-cytotoxicity-cells

Figure 6B: Effects of the ultrasound treatment on cytotoxicity of PDMAEMA-DNA complexes at various ratios. Cells were treated with PDMAEMA-DNA complexes and ultrasound or without (normal group) a low energy ultrasound for 10 sec and 9 cycles. Values are expressed as Mean ± SD in triple experiments.

Discussion

In this study, we used a transient, low intensity ultrasonic system to safely deliver genes in vitro. The resonant frequency around 2 MHz (1.5~2.2 MHz in our use) was chosen because it is approved for clinical applications with advantages of good penetration through soft tissues and no influence on DNA integrity [23-25]. Also, the acoustic wave with a frequency around 2 MHz helps in-depth transmission through the bottom of 96-well plates. Lower frequency (e.g. 500 kHz) would cause significant damage to DNA and a negative effect on cell viability [26]. Up to date, the exposure time and setting of ultrasound treatment (i.e. directions of irradiation, sequences in using ultrasound and cells to be transfected) were different. Our methodology has brought the use of ultrasound closer to the clinical setting. The ultrasound irradiation for only 10 seconds is rare and has only been used for transfection of naked DNA [27]. Meanwhile, very rare research is available on the subject of using ultrasound with polymer or liposome/DNA complexes [28,29].

Mechanisms of ultrasound to increase transfection efficiency have been shown in many studies. Acoustic cavitation effect either from air bubbles or added microbubbles is commonly accepted [30-32].

However, this effect also induce toxicity or apoptosis in cells due to disturbing the cell membranes [33-35] especially with high power of ultrasound (e.g. 130W) [36] or a combination of high power and low frequency (e.g. 20 kHz) [37] as we shown in Figure 1. Nevertheless, a cycle burst ultrasound treatment which we used only up to 10 seconds bypasses the problem of cytotoxicity without compromising the transfection efficiency. Besides the improvement in mechanical bioeffect from ultrasound, our methodology minimized the thermal bioeffect which might also contribute to cell toxicity [38].

Further key findings of our studies were: (1) the ratios for optimal transfection of polymer-DNA complexes are not affected before/ after ultrasound treatment (Figure 3A, 4A, 5A, 6A). This indicates that the ultrasound effect is evenly affecting complexes prepared at all polymer-DNA ratios; (2) the sizes of polymer-DNA complexes before/after ultrasound treatment were also not affected. Therefore, the reason of ultrasound in increasing transfection efficiency before/ after was not due to particle sizes nor cytotoxicity (Figure 3B, 4B, 5B, 6B); (3) for each polymer-DNA ratio, the extent of transfection efficiency enhancement by ultrasound is dependent to the particle size of polymer-DNA complexes, so smaller complex sizes lead to higher transfection efficiency (Figure 4A and Figure 6A).

Conclusions

A transient, low intensity ultrasound was found to be noncytotoxic and exhibited an ability to overcome the major limitations of polymer-DNA complexes such as low transfection efficiency. This new transfection method was shown to be a safe, simple and efficient approach with clinical applications for gene transfer.

References

Select your language of interest to view the total content in your interested language
Post your comment

Share This Article

Recommended Conferences

  • Nano Congress for Next Generation
    August 31-September 01, 2017 Brussels,Belgium
  • Graphene & 2D Materials
    September 14-15, 2017 Edinburgh, Scotland
  • Graphene & 2D Materials
    November 6-7, 2017 Frankfurt, Germany
  • World Congress on Nanoscience and Nano Technology
    October 16-17, 2017 Dubai, UAE
  • World Medical Nanotechnology Congress
    October 18-19, 2017 Osaka, Japan
  • Nanoscienceand Molecular Nanotechnology
    Nov 06-08, 2017 Frankfurt, Germany

Article Usage

  • Total views: 11676
  • [From(publication date):
    April-2015 - Aug 24, 2017]
  • Breakdown by view type
  • HTML page views : 7914
  • PDF downloads :3762
 

Post your comment

captcha   Reload  Can't read the image? click here to refresh

Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

Agri, Food, Aqua and Veterinary Science Journals

Dr. Krish

[email protected]

1-702-714-7001 Extn: 9040

Clinical and Biochemistry Journals

Datta A

[email protected]

1-702-714-7001Extn: 9037

Business & Management Journals

Ronald

[email protected]

1-702-714-7001Extn: 9042

Chemical Engineering and Chemistry Journals

Gabriel Shaw

[email protected]

1-702-714-7001 Extn: 9040

Earth & Environmental Sciences

Katie Wilson

[email protected]

1-702-714-7001Extn: 9042

Engineering Journals

James Franklin

[email protected]

1-702-714-7001Extn: 9042

General Science and Health care Journals

Andrea Jason

[email protected]

1-702-714-7001Extn: 9043

Genetics and Molecular Biology Journals

Anna Melissa

[email protected]

1-702-714-7001 Extn: 9006

Immunology & Microbiology Journals

David Gorantl

[email protected]

1-702-714-7001Extn: 9014

Informatics Journals

Stephanie Skinner

[email protected]

1-702-714-7001Extn: 9039

Material Sciences Journals

Rachle Green

[email protected]

1-702-714-7001Extn: 9039

Mathematics and Physics Journals

Jim Willison

[email protected]

1-702-714-7001 Extn: 9042

Medical Journals

Nimmi Anna

[email protected]

1-702-714-7001 Extn: 9038

Neuroscience & Psychology Journals

Nathan T

[email protected]

1-702-714-7001Extn: 9041

Pharmaceutical Sciences Journals

John Behannon

[email protected]

1-702-714-7001Extn: 9007

Social & Political Science Journals

Steve Harry

[email protected]

1-702-714-7001 Extn: 9042

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords