Make the best use of Scientific Research and information from our 700+ peer reviewed, Open Access Journals that operates with the help of 50,000+ Editorial Board Members and esteemed reviewers and 1000+ Scientific associations in Medical, Clinical, Pharmaceutical, Engineering, Technology and Management Fields.
Meet Inspiring Speakers and Experts at our 3000+ Global Conferenceseries Events with over 600+ Conferences, 1200+ Symposiums and 1200+ Workshops on
Medical, Pharma, Engineering, Science, Technology and Business

Depicting Respiratory Characteristics of Blood Pressure Signal by Using Empirical Mode Decomposition

Chia-Chi Chang1,2,3, Tzu-Chien Hsiao1,3,4 and Hung-Yi Hsu5,6*

1Biomedical Electronics Translational Research Center, National Chiao Tung University, Taiwan, R.O.C

2Department of Electronics Engineering and Institute of Electronics, National Chiao Tung University, Taiwan, R.O.C

3Institute of Biomedical Engineering, National Chiao Tung University, Taiwan, R.O.C

4Department of Computer Science, National Chiao Tung University, Taiwan, R.O.C

5Department of Neurology, School of Medicine, Chung Shan Medical University, Taichung, Taiwan, R.O.C

6Section of Neurology, Department of Internal Medicine, Tungs’ Taichung Metro Harbor Hospital, Taichung, Taiwan, R.O.C

*Corresponding Author:
Hung-Yi Hsu
Department of Neurology
Tungs’ Taichung Metro Harbor Hospital
No. 699, Sec. 1, Jhongci Road, Wuci District
Taichung 435, Taiwan, R.O.C
Tel: +886-9-10597960
Fax: +886-4-26582193
E-mail: [email protected]

Received date: July 08, 2014; Accepted date: October 20, 2014; Published date: October 24, 2014

Citation: Chang CC, Hsiao TC, Hsu HY (2014) Depicting Respiratory Characteristics of Blood Pressure Signal by Using Empirical Mode Decomposition. J Pulm Respir Med 4:209. doi:10.4172/2161-105X.1000209

Copyright: © 2014 Chang CC, et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

Visit for more related articles at Journal of Pulmonary & Respiratory Medicine

Abstract

Aim: To explore adequate parameters for EMD of ABP signal; to determine the intrinsic characteristics of ABP waveform through the analysis of IMFs’ averaged period and its energy density; to examine the effect of different respiration patterns on IMFs extracted from ABP waveform by CEEMD.

Arterial blood pressure (ABP) reflects cardiac function, vessel compliance, and cardiorespiratory interaction and ABP analysis provides the estimators of this physiological information. But it is inconvenient for quantitative ABP assessment due to several influences, such as respiration. Recently, a novel adaptive method, called empirical mode decomposition (EMD), was proposed, and it was useful for non-stationary intrinsic characteristics extraction. Though some literatures examined that EMD helps for physiological signal analysis study, the method applied for ABP signal still needs further investigation. This study proposed a standard procedure of specific EMD for ABP intrinsic characterization during spontaneous breathing, 6-cycle breathing, and hyperventilation. The extracted components, called intrinsic mode functions (IMFs), were determined with the examined parameters, including ensemble number, added noise, and the stop criterion. The IMFs of ABP signal were categorized into five major intrinsic components, including the noise and irregular fluctuation (IMF1), beat-to-beat cardiac intervals (IMF2), characteristics of pressure waveform morphology (IMF3), base beat (IMF4), and respiratory related fluctuation (IMF5 and IMF6).

The results showd that the characteristics of IMFs were quantified by averaged period and corresponding energy density with good reproducibility. The proposed algorithm produced meaningful IMFs representing the cardiac rhythm, intrinsic waveform mophology, and the intrinsic influence of respiration fluctuations. EMD helps for analyzing the underlying mechanisms of control processes, including cardiorespiratory coupling and interactions among organ systems at multiple time scales.

Keywords

Arterial blood pressure; Respiration; Intrinsic mode function; Empirical mode decomposition; Hilbert-Huang transform

Introduction

Arterial blood pressure (ABP) is one of the most important parameters of systemic circulation. ABP is principally determined by cardiac pumping function and resistance of peripheral vessels, which controlled by autonomic nerve system. Non-invasive ABP waveform has been used to estimate some physiological indices, such as cardiac output, peripheral resistance and arterial compliance [1,2]. The ABP waveform consists of the forward pressure wave generated by the heart and the backward reflection wave reflected back by the branches of vessels [2,3]. The velocity of the reflection pressure wave, which contributes to the morphology of ABP waveform, is an indicator of arterial compliance [1,2]. Analysis of morphologic indices of ABP waveform, such as systolic peaks, diastolic valleys, dicrotic notches, and augmented index, have been used to evaluate the activities of autonomic nerve system [4,5], arterial stiffness [2,3], cardiac function [6] and detection of cardiac arrhythmia [7]. However, most of these algorithms are only suitable for certain physiological states [8,9].

The ABP usually fluctuates in long-term monitoring. Respiratory movement causes the changes of ABP and corresponding changes of heart rate (HR). The effect of respiration on HR, named respiratory sinus arrhythmia, is considered as a surrogate of cardiac vagally modulation. Respiratory sinus arrhythmia has been widely applied in the calculation of spontaneous baroreflex sensitivity [10], though the precise phase dependency remains unclear. On the other hand, the extent of ABP fluctuation during respiration is related to central blood volume and cardiac-pulmonary coupling [11]. The regulation relationship between respiratory movement, BP and HR had been studied by using the fast Fourier transform (FFT) or discrete Wavelet transform (DWT) as frequency domain analysis [12]. FFT and DWT had been used for waveform decomposition in time-frequency characteristics researches, including heart rate variability [13] and blood pressure variability [12,14,15], analysis. However, these well-known transforms caused signal distortion and information loss due to the limitation caused by fundamental assumption, such as sinusoidal linear combination in FFT or discrete wavelet function in DWT. In recent years, Hilbert-Huang transform (HHT) [16] has been used increasingly in data processing researches because of its adaptive capability on non-stationary and non-linear decomposition. The distortion of original signals was controlled and limited, because HHT is fundamentally based on the entire morphology of waveform [16]. HHT may help to specify slow or non-rhythmic fluctuation of ABP.

The capability of HHT in dealing with non-linear and non stationary signal comes from essential pre-process, called empirical mode decomposition (EMD). The EMD, pioneered by N.E. Huang et al, decomposes non-linear and non-stationary time series into finite set of mono-components, called intrinsic mode functions (IMFs) [17]. The EMD extracts the IMFs iteratively by detrending operation, called sifting process, based on the morphology of waveform. The essence of sifting process is based on iteratively energy associated extraction at each time scale. The EMD has been applied on HHT as a new timefrequency analysis method in various applications [18]. Recently, Huang et al. characterized white noise by the spectral energy density and the averaged period [19]. This method could qualitatively and quantitatively evaluate the intrinsic characteristics of non-linear and non-stationary signal. This method has potential to characterize the intrinsic feature of ABP waveform.

The EMD is able to reduce noise as a filter bank [20-22]. But the EMD decomposition process contains the intermittency phenomenon, called mode mixing problem, owing to the sensitivity of cubic spline interpolation and end effects [16]. The mode mixing problem would lead to the transitional gaps in further examination with Hilbert transform. In order to overcome mode mixing problem, a noise-assisted data analysis method, known as ensemble EMD (EEMD), was proposed [23]. The EEMD helps to eliminating the mode mixing problem by repeated adding white noise of specific standard deviation. The final set of ensemble IMFs is obtained by averaging each corresponding IMF decomposed from different mixtures. The EEMD has been used in several medical studies [24-27], though EEMD is insufficient for characterization of ABP signal owing to its non-zero residue. The residue of added white noise could be removed by adding positive and negative white noises respectively as two mixtures of the source signal and added white noise, which is called complementary EEMD (CEEMD). The CEEMD not only extends the concept of EEMD but also eliminates the residue of added white noises. The characteristics of IMFs extracted by CEEMD are much stable [28]. However, the IMFs extracted by CEEMD are affected by the parameters used in CEEMD, such as ensemble number, added white noise, and stop criterion of IMF determination. The optimal setting for CEEMD applying on ABP analysis has not been standardized.

Objectives and Methods

Subjects and data collection

All measurements were performed in a quiet temperaturecontrolled room. The beat-to-beat ABP waveform was recorded by Task Force® Monitor equipped with a servo-controlled plethysmography (CNSystems, Medizintechnik AG, Graz, Austria). Electrocardiography (ECG), thoracic impedance and end-tidal CO2 concentration (EtCO2; RespSenseTM EtCO2, Nonin Medical Inc., Ply-mouth, Minnesota, USA) were recorded simultaneously. The signals of ABP, ECG and thoracic impedance were recorded and stored by the CNSystem. The analog signal of EtCO2 was fed via an analog-input interface to the CNSystem at a sampling rate of 200Hz, and saved on the hard disc. All data were exported to a computer for later analysis.

Ten subjects (age 47 ± 21.5 male) participated in this study. All recruited subjects were asked to rest quietly in supine position for 10 minutes. After all recorded signals were stabilized, a 10-min baseline recording was performed under spontaneous breathing. Subsequently, recruited subjects were asked to breathe following the examiner’s verbal instruction at a rate of 6 cycles per minute for 2 minutes. After a 5-minute rest, subjects were asked to perform hyperventilation at a rate of 30 cycles per minute for 2 minutes. This study was approved by institutional review board of the hospital. Informed consent was obtained from all subjects before the experiment.

Ensemble empirical mode decomposition

The algorithm of EMD contains several steps. First, the local extrema in the time series x(t) were identified by peak-valley detection. The upper envelope L(t) and lower envelope L(t) were calculated by cubic spline interpolation based on the local maxima and the local minima. Both envelopes covered x(t) at each time scale. The trend waas estimated by the average of U(t) and L(t) .

image (1)

The first intermidiate component ( h1 t) was extracted by subtracting the trend from the original time series x(t) , as the detrending process.

image (2)

The subtraction was performed iteratively until the trend satisfied the predetermined criterion. The predetermined criterion is adopted the value of the standard deviation of the trend m1 (t) , which was seen as a steady constant trend while the value is below 0.2.

image (3)

h 1k(t) would be considered as an IMF only if the trend satisfies the criterion after k times of the subtraction process.

image (4)

The first residue was calculated by the equation (5).

image

The residue ri(t) was the target signal of ith iteration of EMD for the ith component extraction. After n iteration, x(t) was decomposed into n IMF1(t)~ IMFn (t) , and one residue,rn(t), which can be either the steady trend or a constant.

image (6)

EMD decomposes the non-stationary signal into a finite set of IMFs without information loss or distortion, and the results were refined by EEMD and much further refined by CEEMD, which added white noise into the source signal before EMD and got the final IMFs by average the IMFs corresponding to the added white noise. The added times of the white noise were called ensemble number and presented the times of EMD. This study adopted CEEMD for the ABP waveform decomposition.

According to the noise dependency of noise-assisted data analysis method, the variation of analysis results with different white noise would be considered and verified at first. For eliminating the noise effect of CEEMD, different processing parameters for CEEMD including the magnitude of white noise, ensemble number, and stop criteria were tested. Adequate setting parameters used in this study was selected by the consistency of IMF features in different physiological situation, including baseline, 6-cycle breathing and hyperventilation. The reproducibility of the characteristics of IMFs depends on its variation between repeated analyses. The reproducibility of the decomposition results was evaluated by time sliding window variation with 10 trails. The result of CEEMD was stabilized while the ensemble number, which presents the times of ensemble iteration with added white noise, is greater than 200. The results suggested that 200 ensemble number is enough for ABP signal analysis. The analysis system used in this study was developed by using a commercial programming platform (LabVIEW, version 2011, National Instruments Corp., Austin, TX, USA).

Determination of intrinsic mode function

The IMF is the function that satisfies the condition that the mean of the upper envelope and lower envelope, as defined by local extrema, approximates zero at any time instant [29]. However, the mean envelope is hard to achieve zero because of the non-stationary signal interference. There were several stop criteria for IMF determination, such as standard deviation, S number criterion, energy difference tracking or amplitude ratio [30]. Based on different stop criterion, the IMF decomposed from source signal would be different with various fundamental definitions. This study applied the direct standard deviation of mean envelope as the stop criterion rather than the standard deviation of the division of mean envelope by the intermediate signal. The IMF extraction would be faster than the original EMD stop criterion and well controlled due to its quick convergence.

Averaged period and energy density

The CEEMD technique is usually utilized for Hilbert transform pre-process as the whole process of HHT and for mono-component extraction in order to avoid the negative frequency effect [16]. However, the marginal spectrum of HHT spectrum has the effect of precise characterization, called intra-wave frequency modulation, and it makes non-stationary quantitative evaluation much difficult in specific circumstance, such as all physiologic challenges. The characteristics of each IMF as non-stationary mono-component could be defined by the distribution of energy density and its corresponding averaged period. This method was originally used to study the characterization of white noise by EMD and to evaluate the distribution of energy density and corresponding averaged period of white noise [19].

image (7)

image (8)

En is the energy density of the nth IMF and Sh T n , is the Fourier spectrum of the nth IMF as the function of ln T . T is the period along the axis of the spectrum after changing variable, and image is the estimator of the averaged period of the nth IMF.

The characterization of white noise IMFs was verified by Monte Carlo method, which generated 1000 different white noise and decomposed each of them in order to examine the confidence interval of the distribution of the intrinsic noise component [19]. The sum of logarithmic averaged period image and logarithmic energy density lnEn would approximate to a constant [31]. The averaged period and energy density had potential to demonstrate the characteristics of IMFs extracting from non-stationary source signal by EMD. In this study, this method was applied to determine the characteristics of IMFs.

Results

Selection of white noise

The results of noise-assisted data analysis, such as CEEMD, would vary when different white noises are used. This study tested different added white noises in CEEMD and the results are shown in Figure 1. The mode mixing problem is obviously in the result of EMD in Figure 1a and is markedly attenuated by CEEMD. The IMFs are well discriminated along with increasing standard deviation of added white noise. The characterization of IMFs by averaged period and energy density was well separated without overlapping in noise-assisted analysis. High-frequency and irregular fluctuation appears in IMF5 in Figure 1e when the standard deviation of added white noise was greater than one-tenth of standard deviation of source signal. According to these observations, one-fifteenth of standard deviation of source signal as the standard deviation of noise was selected as the setting of added white noise for ABP signal decomposition in CEEMD in this study.

pulmonary-respiratory-medicine-original-signal

Figure 1: Results of EMD and CEEMD for ABP signal with different added noise. In all panels, top graph presents the original ABP signal, IMF1-IMF7 and the residue are listed below, and the bottom graph is the characterization plot with logarithmic averaged period and logarithmic energy density of each IMF. (a) EMD of ABP signal, CEEMD with (b) 0.1, (c) 0.2, (d) 1/15 time of standard deviation (SD) of original signal, and (e) 1/10 time of SD of original signal as the SD of noise.

Reproducibility analysis

Ten 1-minute segments of resting ABP signal from each subject was sampled and decomposed by CEEMD respectively. The characteristics of IMFs were similar within the same individual. The coefficient of variation (CV) of logarithmic averaged period and the CV of logarithmic energy density in each subject were calculated for the reproducibility verification. Figure 2 shows that the CV of logarithmic averaged period and the CV of logarithmic energy density are small. The CV of logarithmic averaged period of IMF4 is relatively high owing to its mean approaching zero. The CV of both the logarithmic averaged period and energy density were high in IMF5 and IMF6 because of variable respiration-related fluctuation of ABP between subjects (further discussion in next paragraph). The results suggested that the methods used for characterization of IMFs in this study were reliable. Even though the ABP signal was recorded at different time points, the CEEMD of ABP waveform had good reproducibility in different individuals

pulmonary-respiratory-medicine-energy-density

Figure 2: The coefficient of variation (CV) of (a) logarithmic averaged period and of (b) logarithmic energy density in all subjects for each IMF, series number 1-7 present the number of IMF and 8 presents the residue of CEEMD.

Characteristics of IMFs during different breathing patterns

The results of CEEMD decomposition of ABP signals during different breathing patterns are shown in Figure 3. The characteristics of IMFs during spontaneous breathing, 6-cycle breathing, and hyperventilation were similar. The IMFs derived from CEEMD decomposition of ABP signal were categorized into five major components, including noise, beat-to-beat time intervals, characteristics of pressure waveform, base beat, and respiratory related fluctuation with the same setting of CEEMD. The IMF1 derived from CEEMD of ABP signal shows the most high frequency component in ABP, which may contain intrinsic characteristics of white noise with orther unexpected fluctuations demonstrated in Figure 4. The IMF2 shows peak-to-peak pressure pulse waveform as shown in Figure 5. Figure 5 shows that the morphology of ABP waveform was demonstrated by the first four IMFs in a small time scale, and the influence of respiration was eliminated from these four IMFs. The IMF5 and IMF6 associate with respiration related fluctuation of ABP, as shown in Figure 3, and present the influence of respiration, which was extracted from the orignal ABP signal and was eliminated from the other IMFs. The results of the logarithmic averaged period and corresponding logarithmic energy density were summarized in Table 1.

pulmonary-respiratory-medicine-baseline-resting

Figure 3: Results of CEEMD for ABP signal during baseline, 6-cycle breathing and hyperventilation. All panels represent CEEMD of ABP signal, where top graph presents the original ABP signal, IMF1-IMF7 and residue after IMF extracted are listing below, and bottom graph is the corresponding recording of end-tidal CO2 (EtCO2) concentration. (a) baseline resting spontaneous respiration; (b) during paced breathing at 6 cycles per minute. (c) during hyperventilation at 30 cycles per minute

pulmonary-respiratory-medicine-energy-density

Figure 4: Monte Carlo verification of the relation between the logarithmic averaged period and the logarithmic energy density of IMFs (empty squares with labels) and noise (clusters of dots).

pulmonary-respiratory-medicine-listing-below

Figure 5:Results of CEEMD for different ABP waveform morphology in three different subjects. All panels represent CEEMD of ABP signal, where top graph presents the original ABP signal, IMF1-IMF4 are listing below, and the bottom graph is the characterization plot with logarithmic averaged period and logarithmic energy density of each IMF.

  Baseline 6-cycle Breathing Hyperventilation
lnT lnE lnT lnE lnT lnE
IMF1 -2.43 ± 0.13 2.4 ± 0.76 -2.44 ± 0.15 2.17 ± 1.04 -2.47 ± 0.21 2.58 ± 0.9
IMF2 -1.67 ± 0.12 5.96 ± 0.51 -1.66 ± 0.11 5.91 ± 0.68 -1.62 ± 0.11 6.09 ± 0.55
IMF3 -0.85 ± 0.09 7.39 ± 0.51 -0.85 ± 0.08 7.35 ± 0.6 -0.88 ± 0.09 7.63 ± 0.47
IMF4 -0.16 ± 0.11 8.33 ± 0.73 -0.12 ± 0.12 8.31 ± 0.74 -0.23 ± .012 8.25 ± 0.72
IMF5 0.92 ± 0.26 3.79 ± 0.79 0.84 ± 0.2 3.75 ± 0.62 0.93 ± 0.17 4.91 ± 0.61
IMF6 1.85 ± 0.21 3.24 ± 0.7 2.27 ± 0.19 5.35 ± 1.07 1.86 ± 0.27 3.49 ± 1.52
IMF7 2.84 ± 0.2 3.45 ± 1.1 2.77 ± 0.24 4.86 ± 1.03 2.91 ± 0.26 3.68 ± 1.52
Residue 3.57 ± 0.2 2.69 ± 1.15 3.65 ± 0.2 3.45 ± 1.45 3.58 ± 0.19 2.98 ± 1.43

Table 1: The logarithmic averaged period and corresponding logarithmic energy density of each IMF during different breathing patterns.

Beat-to-beat time intervals extracted from ABP signal

The IMF1 is within the confidence interval of energy density and averaged period of white noise by Monte Carlo verification as shown in Figure 4. The IMF1 represented the most high frequency component in ABP signal, which was more likely to be contaminated by noise caused by some artifacts or the other external influences in Figure 5b. IMF2 presents the sharpest changes of beat-to-beat ABP and could be a surrogate to determine the beat-to-beat time intervals which is derived from ECG recording conventionally. The beat-to-beat time series were calculated based on IMF2, as shown in Figure 6. The automatic peak detection was applied for first order difference of IMF2 and the time intervals were calculated by peak-to-peak duration, as described in the literature study [8]. Then, the time series were generated from the time intervals by spline interpolation, as an approach to get the beatto- beat time intervals. The interclass correlation test showed excellent correlation between beat-to-beat time intervals extracted from ABP signal and beat-to-beat cardiac intervals from ECG recording during baseline, 6-cycle breathing and hyperventilation (all interclass correlation coefficient > 0.980 in study subjects).

pulmonary-respiratory-medicine-interval-series

Figure 6: An illustration of beat-to-beat cardiac interval extracting from the IMF2 of ABP signal and relationship with respiration. (a) the original IMF2 of ABP signal, (b) the peak detection of R-wave in ECG (solid line) and that of first order difference of IMF2 (dotted line), (c) the RR intervals series in ECG (solid line) and the beat-to-beat time interval series from IMF2 (dotted line), and (d) the EtCO2 concentration.

Characteristics of ABP waveform morphology

Figure 5a shows that the amplitude of IMF3 was larger when the ABP waveform was sharper, while in Figure 5c, the amplitude of IMF3 was smaller when the ABP waveform was flat. Similarly, the averaged period and energy density of IMF3 are different when the shape of ABP waveform varies between different individuals, as shown in Figure 5. The IMF4 represents the fundamental base beat waveform as the ABP waveform carrier, and its amplitude and frequency can indicate the related characteristics of ABP waveform. The characterization plot shows that IMF4 has the largest energy density in Figure 5. The logarithmic averaged period of IMF4 is approximately zero due to the beat-to-beat time period round about 1 second in normal subjects.

Respiration related fluctuations of ABP Signal

The respiration-related fluctuation of ABP signal was shown in IMF5 or IMF6, as shown in Figure 3. The EtCO2 concentration was highly concordant with the IMF6 during slow 6-cycle breathing and with IMF5 during rapid hyperventilation. The Bland-Altman plot showed good agreement between the logarithmic averaged period with IMF6 of ABP signal and EtCO2 concentration during 6-cycle breathing, shown in Figure 7. The logarithmic averaged period with IMF5 of ABP signal also had good agreement with EtCO2 concentration during hyperventilation. The phase of ABP fluctuation had a reversal relationship with that of EtCO2 concentration in different respiratory patterns. The amplitude change of respiration signal correlated with the energy density of corresponding IMF. The results in Table 1 showed that the logarithmic averaged period provides the estimation of the relevant main period of each IMFs. The energy density of IMF6 increased during 6-cycle breathing and the energy density of IMF5 increased during hyperventilation.

pulmonary-respiratory-medicine-averaged-period

Figure 7: Agreement between logarithmic averaged period of IMF6 of ABP signal and that of EtCO2 during 6-cycle breathing by using Bland-Altman plot. The mean difference and the limits of agreement are indicated.

Discussion

In general, CEEMD has good capability for non-stationary signal decomposition, but its result depends on the setting of several parameters. The proper selection of added white noise of CEEMD and the proper stop criterion of IMF determination are important to characterize the ABP signal [32]. The study suggested that CEEMD of ABP signal produces reliable results by using 1/15 time of standard deviation of ABP source signal as the standard deviation of added noise of CEEMD and directly referred standard deviation of intermediate signal as the stop criterion for ABP signal characterization. The optimal parameters of CEEMD analysis would vary when different physiological signals are the targets of CEEMD. This study demonstrated the process to achieve reliable analysis.

CEEMD is able to extract important physiologic and pathologic information from ABP signal. The sifting process gives CEEMD ability to discriminate non-stationary orthogonal characteristics of morphology, such as frequency, in various time scales. Each IMF decomposed by CEEMD represents a frequency-amplitude modulation in narrow frequency band that can be related to a specific physiologic process [33]. However, most of previous studies applied EMD in analysis of systolic BP tachogram only [34], or just focused on the characteristics of one or two IMFs [27,34]. This study demonstrated the important features of all IMFs and their possible physiological meanings, which were verified by multi-modality monitoring and performing different respiratory maneuvers. By using CEEMD, the ABP signal can be decomposed into meaningful IMFs representing cardiac intervals, characteristics of pressure waveform, and respiratory pattern in this study.

The first four IMFs were regarded as non-physiological interferences owing to its frequency range and contained rich information of intrinsic waveform mophology. By the adequate parameters setting of CEEMD, the non-physiological artifacts and noises were restricted within IMF1. The CEEMD effectively eliminated artifacts in the other IMFs. Thus, the beat-to-beat cardiac interval and the mophology analysis, such as reflection wave analysis, were estimated accurately by further processing without the other unexpected influences.

The morphology of ABP waveform is the summation of forward pressure wave and backward reflection wave, and is considered as the characteristics of vessel compliance referred to the reflection coefficient [35]. Certain IMFs, for example IMF3 and IMF4 in this study, preserved the features of original ABP waveform morphology. Some indices of arterial stiffness and atherosclerosis could be derived from these IMFs [27,34]. Further post-processing to characterize subtle changes in these IMFs may have potential to be used in classification of ABP waveform for pulse diagnosis [36] and cardiovascular researches.

The respiratory influence of ABP signal was observed in IMF5 or/ and IMF6 in different respiratory patterns. The adaptive sifting process of CEEMD, which sifting the signal iteratively from high frequency to low frequency in various time scale, distributes the respirationrelated ABP changes to different IMF depending on the frequency of respiration. The phenomenon was quantitative assessed by the averaged period, shown in Table 1. The energy density of IMF6 increased during 6-cycle breathing and the corresponding logarithmic averaged period was 2.27, which means that the averaged period was 9.68 sec (~10 sec) and it met the period of 6-cycle breathing. On the other hand, the energy density of IMF5 increased during hyperventilation and the corresponding logarithmic averaged period was 0.93, which means that the averaged period was 2.53 sec (~10 sec) and it met the period of hyperventilation. The good agreement between logarithmic averaged period of EtCO2 and that of the corresponding IMF suggested that respiratory pattern could be evaluated by CEEMD of ABP signal. By using CEEMD, ABP recording not only provided hemodynamic information, but also had potential to detect abnormal respiratory pattern such as sleep apnea. The ABP change had a reversal relationship with EtCO2 concentration in different respiratory patterns [37,38]. The phase delay between EtCO2 signal and respiratory fluctuation of ABP signal was similar to previous reports [39].

The CEEMD had good capability of non-stationary sifting and was served as the time-variant filter bank adaptively in various time scales. The IMF decomposed by CEEMD represents a posteriori monocomponent in narrow frequency band, which might be related to a specific physiologic process, and it might help the physiological study finding the optimal frequency band of regulation in multiple time scale. The IMF7 and the following IMFs have the potential to explore the very low frequency band (<0.04Hz), i.e. high logarithmic averaged period (>3.2) on characterization plot of IMF, in long-term ABP monitoring. Cardiovascular regulation in this frequency range may result from the metabolic, humoral, or temperature modulation [5]. The EMD decomposition of short-term ABP recording is not able to evaluate these low frequency changes.

This study proposed a simple method to quantitatively evaluate the non-stationary characteristics of real medical signal, ABP for example, by using averaged period and energy density. These two parameters contained the morphology information extracted by CEEMD, and quantified the morphology information based on spectral integration. The averaged period and energy density had good reproducibility on repeated measurements in this study. However, these two parameters could only depict the differences in ABP waveform morphology roughly.

This study has some limitations. First, the resolution of the averaged period is limited by the sampling rate of the original source signal, and the bound of averaged period is determined by the recording period. Secondly, the characteristics of IMFs are mainly determined by the parameters of CEEMD. It seriously limits the IMF usefulness in characterization. The problem is compounded by the fact that relatively few researchers can actually study the IMF with the same definition, making it difficult for applying the CEEMD and comparison between studies. The time complexity of CEEMD belongs to non-deterministic polynomial time and it is insufficient for real-time processing. The potential applications of CEEMD merit more studies under standardized parameter setting, including 1/15 added white noise ratio, 200 ensemble number, and 0.2 as the value of stop criterion of the sifting process.

Conclusion

This paper demonstrates useful methods to improve the reliability of CEEMD of ABP signal. The characteristics of IMFs provides information about cardiac rhythm, intrinsic waveform mophology of ABP signal, and intrinsic influence of respiration fluctuations of ABP signal during different respiratory patterns. The mono-components extraction of ABP in adaptive time scale might help to discover the optimal frequency band of different physiological mechanisms. The CEEMD of ABP signal is able to provide important physiologic information without simultaneous ECG and respiratory monitoring. This study might serve as a guide to analyze specific IMFs components for ABP signal, and to evaluate the intrinsic characteristics of ABP signal qualitatively and quantitatively by averaged period and energy density. The proposed method helps for the researches on applications of CEEMD in pulse diagnosis and the exploration of optimal frequency band of physiological control process.

Acknowledgements

This work was fully supported by the Taiwan Ministry of Science and Technology under grant numbers MOST-103-2220-E-009-006, MOST-103-2221-E-009-139 and MOST-103- 2218-E-009-016 and in part by ‘Aim for the Top University Plan’ of the National Chiao Tung University and Ministry of Education, Taiwan, R.O.C. This work was also supported in part by the UST-UCSD International Center of Excellence in Advanced Bioengineering sponsored by the Taiwan National Science Council I-RiCE Program under grant number NSC-101-2911-I-009-101.

References

Select your language of interest to view the total content in your interested language
Post your comment

Share This Article

Recommended Conferences

Article Usage

  • Total views: 11477
  • [From(publication date):
    December-2014 - Jun 29, 2017]
  • Breakdown by view type
  • HTML page views : 7729
  • PDF downloads :3748
 

Post your comment

captcha   Reload  Can't read the image? click here to refresh

Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords