Make the best use of Scientific Research and information from our 700+ peer reviewed, Open Access Journals that operates with the help of 50,000+ Editorial Board Members and esteemed reviewers and 1000+ Scientific associations in Medical, Clinical, Pharmaceutical, Engineering, Technology and Management Fields.
Meet Inspiring Speakers and Experts at our 3000+ Global Conferenceseries Events with over 600+ Conferences, 1200+ Symposiums and 1200+ Workshops on
Medical, Pharma, Engineering, Science, Technology and Business

Low Intensity Low Frequency Ultrasound Surface Acoustic Wave Treatment for Metatarsal Fractures

Jonathan Rosenblum1*, Sean Rosenblum2 and Andy Karpf3

1Private Practice, Jerusalem, Israel

2Private Practice, Lodi, NJ, USA

3Private Practice, Tel Aviv, Israel

*Corresponding Author:
Jonathan Rosenblum
17 Shimon St, Bet Shemesh
Israel 99543
Tel: +972 50 595 5161
E-mail: [email protected]

Received date: June 30, 2017; Accepted date: August 07, 2017; Published date: August 17, 2017

Citation: Rosenblum J, Rosenblum S, Karpf A (2017) Low Intensity Low Frequency Ultrasound Surface Acoustic Wave Treatment for Metatarsal Fractures. J Sports Med Doping Stud 7: 193. doi:10.4172/2161-0673.1000193

Copyright: © 2017 Rosenblum J, et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution and reproduction in any medium, provided the original author and source are credited.

Visit for more related articles at Journal of Sports Medicine & Doping Studies

Abstract

Fractures are among the most common injuries we come across. Following is one such case that presents and optional way of fracture healing at a decreased time to fracture union and increased fracture union rate through the use of ultrasonic waves. Reported here are cases of 6 where healing was continued using low intensity low frequency ultrasound diathermy patch for the treatment of metatarsal fracture.

Keywords

Metatarsal; Low intensity ultrasound; Fracture healing

Introduction

Adjuncts to the treatment of fracture healing are aimed at decreasing time to fracture union and improving fracture union rates. Low-intensity pulsed ultrasound is emerging as a safe, cost-effective and reliable treatment for both fresh fractures and fracture nonunions [1].

The effect of ultrasound on the healing of cortical fractures has been reported in closed or grade-I open tibial fractures. Ultrasound treatment consisting of 30 mW/cm2 for 20 min/day led to a significant (24%) reduction in the time to clinical healing (average, 86 ± 5.8 days in the treatment group compared with 114 ±10.4 days in the control group; p=0.01). A 38% decrease in the time to overall (clinical and radiographic) healing (average, 96 ± 4.9 days in the treatment group compared with 154 ± 13.7 days in the control group; p=0.0001). The patients’ compliance with daily use of the ultrasound device was high, and there were no complications related to its use [2].

We report use of a novel low intensity low frequency ultrasound diathermy (LILFU) patch for the treatment of metatarsal (MT) fractures in a series of 6 patients where the healing was expedited.

Case Presentation

Six patients (three men, three women) aged 20-47 years had presented with solitary fractures of a metatarsal (5th MT in five, 3rd MT in one) with prior treatment with plaster cast immobilization for 3 - 12 weeks. All were treated with Surface Acoustic Wave (SAW) LILFU patch (NanoVibronix Inc. Elmsford, NY). Five were treated for three weeks and one was treated for two weeks. Xray evidence of healing was present in all 6 patients at the end of their treatment with SAW. There was a reported average return to normal function of 96% (Table 1).

Pt No. Age(Yrs) Sex Fracture Location Duration before Presentation Cast Treated with SAW (days) Pain pre-treatment Pain Post-treatment Healing Evidence On Xray Return to function (%)
1 20 M 5th MT base 21 days Y 14 8 3 Y 100
2 26 F 5th MT base 8 weeks Y 21 9 1 Y 100
3 46 M 5th MT base 12 weeks Y 21 6 1 Y 90
4 21 M 5th MT shaft 21 days Y 21 10 2 Y 90
5 47 F 3MT shaft stress Fracture 12 weeks N 21 8 2 Y 100
6 44 F 5th MT shaft 21 days Y 21 8 1 Y 100

Table 1: Clinical observations.

Average pain score (VAS) reduced from pre-treatment average of 9.8 /10 to post-treatment average of 2/10.

Patient is a 21 year old male soldier who presented with a transverse fracture of the proximal 5th MT shaft secondary to an inversion injury of the ankle. Patient was treated conservatively for 2 weeks before presentation with an elastic bandage. On examination, there was a mildly edematous foot with contusion over the dorsolateral portion of the foot and pain with weight bearing and severe pain on palpation at the point of the fracture line and the styloid process. Treatment with SAW device (Nanovibronix Inc. Elmsford, NY USA) was initiated for 3 two hour sessions daily for two weeks. Pain was relieved by day 2 of the treatment. By the end of the second week the edema was almost resolved and the patient was able to bear weight and ambulate using only a cane. The presenting pain on palpation along the lateral aspect of MT5 was totally resolved by the second week of treatment. Radiologically there was callus seen with bridging across the whole of the fracture line at this time (Figure 1).

sports-medicine-doping-studies-nanovibronix-elmsford

Figure 1: SAW LILFU device (NanoVibronix Inc. Elmsford, NY USA).

Discussion

Ultrasound stimulates angiogenesis, thus increasing blood flow to the fracture site and inherently delivering key components, such as growth factors and cytokines that are necessary for the normal healing process [3].

Ultrasound stimulates chondrogenesis and cartilage hypertrophy, resulting in an earlier onset of endochondral formation and thus leading to an increase in stiffness and strength of the fracture site [4,5].

Conventional Ultrasound High Frequency 1-3 MHz had been earlier used in fracture healing as an adjunct. It transmits energy locally and deeply into the body without focusing on superficial structures. This can cause a “Deep Overheat” which clinically presents with cavitation and thermal energy. In clinical practice conventional ultrasound is expensive and the implements are bulky. Because of this, regular use of ultrasound has not been successfully accepted in the traditional orthopedic armamentarium for fracture healing, despite an impressive evidence base. Moreover, it is therapist dependent, time consuming and work intensive for the therapist. Human therapist factor causes overall treatment costs to increase greatly.

Low frequency ultrasound

Earlier studies have established biological effects of Low frequency Ultrasound including: pain reduction [6-8], ncreased protein and collagen synthesis as well as stimulation of interleukin B8, increased proliferation of fibroblasts and osteoblasts, stimulation of neoangiogenesis, increased production of vascular endothelial growth factor, stimulation of nitric oxide and prostaglandin E2 production [9,10].

Rosenblum’s callus

The presence of a unique callus formation was noted in the patients treated with SAW LILFU, both in these reported cases as well as in other fracture patients,. In contradistinction to the usual domed and rounded callus or the perpendicular bridging across the fracture line, patients treated with SAW developed a peaked spiked callus that resorbed with time. This callus was planarly parallel to the placement of the patch and extended perpendicularly to the patch (Figure 2).

sports-medicine-doping-studies-rosenblum-sign-note

Figure 2: Rosenblum sign- note the one-sided peaked callus.

The ultrasound devices in the orthopedic market today are mostly high energy –high frequency (MHz) devices. The principal reasons for this are the technical barriers to producing a low frequency-low energy device that can be easily applied in an independent manner. The salient problems are: Low frequency devices require transducers that must be about 10 times thicker than that of the MHz device, a large transducer is difficult to manipulate and its power supply must be 20 times greater than the MHz device.

Current lower intensity devices are not easily applicable for many hours at a time. The evaluated device is a portable, battery operated, low intensity low frequency ultrasound (LILFU) SAW patch system (Figure 1). It sustains a level of energy kept at a safe, low level while administering therapeutic ultrasound, creating a slow release ultrasound effect on the targeted area of injury. SAW can be used up to ten hours continuously or several times a day. The maximum energy output level of this device is lesser than 100 mW/cm2. Thus the device could be safely used continuously, as per American Institute of Ultrasound in Medicine (AIUM) guidelines showing no adverse bio effects. The novel approach of delivering ultrasound allows for longer periods of treatment time while keeping the total amount of energy exposure of the body well below the noxious level as per the guidelines of AIUM.

The SAW LILFU device is used to generate continuous wave ultrasound at 90 kHz with a power output of 0.4 W, through a reusable/disposable patch with applicator that covers an active area of about 6 cm2. The small applicator allows treatment of less accessible body parts viz., the heel, the achilles tendon and the wrist. The device produces no significant sensation at the treatment site other than slight warming. Using the device overnight ensures a high rate of compliance as it is exceedingly simple to use and does not interfere with the patient's daily routine.

Conclusion

The LILFU Surface Acoustic Wave (SAW) device was found clinically effective in expediting healing of metatarsal fractures. Further study and a randomized controlled prospective study are required to further qualify the effect.

References

Select your language of interest to view the total content in your interested language
Post your comment

Share This Article

Recommended Conferences

Article Usage

  • Total views: 335
  • [From(publication date):
    July-2017 - Oct 21, 2017]
  • Breakdown by view type
  • HTML page views : 299
  • PDF downloads :36
 

Post your comment

captcha   Reload  Can't read the image? click here to refresh

Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

Agri, Food, Aqua and Veterinary Science Journals

Dr. Krish

[email protected]

1-702-714-7001 Extn: 9040

Clinical and Biochemistry Journals

Datta A

[email protected]

1-702-714-7001Extn: 9037

Business & Management Journals

Ronald

[email protected]

1-702-714-7001Extn: 9042

Chemical Engineering and Chemistry Journals

Gabriel Shaw

[email protected]

1-702-714-7001 Extn: 9040

Earth & Environmental Sciences

Katie Wilson

[email protected]

1-702-714-7001Extn: 9042

Engineering Journals

James Franklin

[email protected]

1-702-714-7001Extn: 9042

General Science and Health care Journals

Andrea Jason

[email protected]

1-702-714-7001Extn: 9043

Genetics and Molecular Biology Journals

Anna Melissa

[email protected]

1-702-714-7001 Extn: 9006

Immunology & Microbiology Journals

David Gorantl

[email protected]

1-702-714-7001Extn: 9014

Informatics Journals

Stephanie Skinner

[email protected]

1-702-714-7001Extn: 9039

Material Sciences Journals

Rachle Green

[email protected]

1-702-714-7001Extn: 9039

Mathematics and Physics Journals

Jim Willison

[email protected]

1-702-714-7001 Extn: 9042

Medical Journals

Nimmi Anna

[email protected]

1-702-714-7001 Extn: 9038

Neuroscience & Psychology Journals

Nathan T

[email protected]

1-702-714-7001Extn: 9041

Pharmaceutical Sciences Journals

John Behannon

[email protected]

1-702-714-7001Extn: 9007

Social & Political Science Journals

Steve Harry

[email protected]

1-702-714-7001 Extn: 9042

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords