Make the best use of Scientific Research and information from our 700+ peer reviewed, Open Access Journals that operates with the help of 50,000+ Editorial Board Members and esteemed reviewers and 1000+ Scientific associations in Medical, Clinical, Pharmaceutical, Engineering, Technology and Management Fields.
Meet Inspiring Speakers and Experts at our 3000+ Global Conferenceseries Events with over 600+ Conferences, 1200+ Symposiums and 1200+ Workshops on
Medical, Pharma, Engineering, Science, Technology and Business

Modeling, Simulation of 3D Label Free Nano Amperometric Biosensor for Early Diagnosis of Cancerous Cells with Sustainable Interfacial Coefficients

Babu KK*

Gitam University, Vizag, India

*Corresponding Author:
K Kalyan Babu
Assistant Professor, Gitam University, Rushikonda 530045
Vizag, Andhra Pradesh, India
Tel: 8497917773
E-mail: [email protected]

Received Date: September 19, 2016; Accepted Date: September 26, 2016; Published Date: September 30, 2016

Citation: Babu KK (2016) Modeling, Simulation of 3D Label Free Nano Amperometric Biosensor for Early Diagnosis of Cancerous Cells with Sustainable Interfacial Coefficients. J Biosens Bioelectron 7: 222. doi: 10.4172/2155-6210.1000222

Copyright: © 2016 Babu KK. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

Visit for more related articles at Journal of Biosensors & Bioelectronics

Abstract

I would like to model and simulate 3D label free Nano Amperometric Biosensor for drug delivery and detection of cancerous cells. An Amperometric biosensor is one which has a biological element and a transducer. The analysis to whom the transduction to take place is referred to as analyte. The biological element I use in my work is enzyme, it can be even a living cell, DNA and proteins. Enzyme which I use in my work is Glucose Oxidase (GODx). The analyte primitively used in experimentation is hydrogen peroxide (H2O2) and cancerous blood. The GODx reacts with H2O2 and releases out oxygen, the amount of oxygen is calibrated in terms of current in milli amperes, so the biological change is calibrated terms of electrical parameter and so it is called amperometric biosensor. But in actual practice, the process is reversible, we inhale oxygen and exhale CO2, but a biosensor releases Oxygen out and inhales the analyte decomposition. This process is called Direct Current Cyclic Voltammetry. A potentiometric biosensor calibrates the analytes in terms of potential or voltage.

Keywords

Biosensor; Cancer; Interfacial coefficients; Amperometric biosensor; Glucose oxidase; Transducer

Introduction

Construction of amperometric biosensor

A biosensor is one which has outer membrane and Semipermeable membrane, it has 3 electrodes namely working electrode, Reference electrode and counter Electrode the enzyme is applied to working electrode and analyte is kept in the form of bulk solution [1]. The ground surface is referred to substrate. When substrate appears in bulk Solution, the sensor action starts. We apply a fixed potential between counter and reference electrode and vary the potential between working and counter electrode. The variation of potential results in current order of milli amperes [2]. The nano material Carbon Nano tubes can be used as Electrodes, because CNT are hardest materials than graphite and metals. CNTS have good electrical conductivity and ecofriendly to biological applications. Metallic electrodes electrolyze soon before -0.05 V, and sensor action is not fruitful. CNTS have No problems of such kind.

Development of equations

Develop equations for outer membrane under ideal conditions and under stress when a replaceable array is attached [3]. Then inner stress on the sensor increases. This may affect the transduction, so the interfacial coefficients should be adjusted in such a way that there is NO change in Biosensor action.

a) Inner stress also gets affected, so there should adjustable inner parameters which should NOT affect the overall sensing.

b) The interfacial coefficients involve De (diffusion of analyte under external conditions) and Di (diffusion under internal conditions), S (Substrate), P (product) and E (Enzyme) (Figure 1).

biosensors-bioelectronics-amperometric

Figure 1: A simple view of amperometric biosensor.

Following the basic equation of Michaelas Menton:

image(1)

As my sensor is 3 dimensional, consider the basic dimensions X, Y, and Z (Figure 2).

biosensors-bioelectronics-diagram

Figure 2: The above diagram shows the 3 Dimensional view of BIOSENSOR.

The equations governing for the above system are

image(2)

Equations for electrodes:

As there are 3 electrodes, namely working, counter electrode and reference electrode, the equations are given by following the basic NERST EQUATION:

I=N .De. F.Q

I=Current Flow

N=No of electrons

F=Faraday’s Constant=96500coloumbs

Q=Charge developed

De=Diffusion coefficient

Differentiating the above equation WRT time, we get

Di/dt= N.De.F dq/dt.

We apply H2O2 on working electrode and the potential between working and reference electrode is set to -0.05 V. The enzyme is GLUCOSE OXIDASE (C6H1206) is considered in immobilized condition.

The reaction is given by:

image

The biosensor action commences when substrate appears in bulk solution. The oxygen is evolved and is made direct proportional to current in milliamps (Figure 3).

biosensors-bioelectronics-biosensor

Figure 3: The above diagram represents the biosensor under QUASI STEADY STATE CONDITION with enzyme and substrate.

The governing equations for Biosensor actions are: I have considered enzyme under immobilized conditions (QUASI STEADY STATE CONDITION)

image(3)

Where,

De=Diffusion coefficient of enzyme

Dp=Diffusion coefficient of product

Ess=Enzyme under steady state

Sb=Substrate under bulk solution.

Cancer

CANCER is a dangerous disease growing all over the world exponentially day by day. Cancer is also known as carcinoma and tumor [4]. Cancer is not transferrable, but it causes a negative mind set for the other persons who live nearer to cancer patient. There are many kinds of cancer namely Brain cancer, lung cancer, stomach cancer, liver cancer, breast cancer, blood cancer leg cancer, thyroid cancer etc. Cancer cells appear as living cells initially, but slowly they lose mass and become light weight and loose contact with skin and perish the patient. Cancer can be eradicated by RF Diathermy, radiation therapy, where UV light is exposed over the cancer cells and destroy them permanently. Cancer is also termed to be carcinoma [5]. Cancer is not hereditary disease; it can be caused to any person at any time. The main causes of cancer in males are because of smoking tobacco, drinking alcohol. Drinking too much of alcohol causes liver cancer either in males or females. Smoking in human beings causes formation of thick mass in lungs which is very dangerous to lungs which finally leads to formation of lung carcinoma. Cervix is females reproductive organ. It leads to release of hormones every time. During intercourse the release of hormones will be more. Having multiple sex partners, leads to cervix cancer, aids. But the cervix cancer can be diagnosed by examining white discharge from cervix. Cancer is correctly confirmed by testing estrogen, progesterone from white discharge from cervix or menstrual blood during menses in females.

Characterization and Procedure for Diagnosing Cancer Using Biosensor

Procedure for diagnosing cancer is by taking a little blood sample from the area where it is attacked. The biosensor is made ready for testing the blood sample. It is dipped in ferroferri solution and Cyclic Voltametry is performed. It leads to formation of oxidation and reduction cycles. The difference between the positive peak and negative peak is calculated. If the difference is 0.01 V, then it is ready for testing. After this ferroferri test, the biosensor is tested for PANI (electro chemical polymerization of ANALINE).This is done by mixing HCL acid and Analine acid in appropriate ratios and poured into the biosensor cell. The 3 electrodes are Glassy Carbon for working electrode, Reference electrode is made of Agcl or Ag. The counter electrode is made of platinum [6].

Now Glucose Oxidase (GODx) is drop casted though micropipette into the bulk solution and this is tested for Cyclic voltammetry in Electro com software. Now the glassy carbon is polymerized and coated with GODx. After the above test, blood is mixed with bulk solution; the blood sample is referred to as ANALYTE. The analyte mixed bulk solution is tested for detection of cancer. Cancer cells with less amount of oxygen lead to low value of current. Whereas non cancer cells with high amount of oxygen lead to high current in redox cycle.

Result

Interfacial coefficients

Interfacial Coefficients=N.De.F.Q

By using the above equation a small program is written in MATLAB for Current versus De. The result is shown below (Figure 4).

biosensors-bioelectronics-variation

Figure 4: The above figure shows the variation of CURRENT vs De, which is increasing sharply for non cancerous cells. The result will be inverted in cancerous cells.

Nano technology

Nano materials such as Nano wires and Graphene can be used in fabrication of device. Graphene made electrodes ors are used for their feasibility to biological environment with Good Young s modulus, Quality factor and Stress strain relationship.

Analysis

With this Biosensor, I could do Mathematical modeling and simulate it numerically. With the developed equations, we can fabricate the device for the purpose of early diagnosis of CANCER with the simulated outputs. This device can be used in Health Care and in Clinics in future to know the condition of healthy Bio molecules and Diseased Bio molecules.

Conclusion

In this paper I discussed the mathematical modeling, characterization and simulation of amperometric biosensor with interfacial coefficients in early Diagnosis of cancer.

References

Select your language of interest to view the total content in your interested language
Post your comment

Share This Article

Relevant Topics

Article Usage

  • Total views: 8457
  • [From(publication date):
    December-2016 - May 25, 2018]
  • Breakdown by view type
  • HTML page views : 8362
  • PDF downloads : 95

Review summary

  1. Dinesh Killana
    Posted on Oct 16 2016 at 7:53 am
    Excellent article. Very good research and very well written. Congrats Kalyan Babu Killana!
 

Post your comment

captcha   Reload  Can't read the image? click here to refresh

Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2018-19
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

Agri & Aquaculture Journals

Dr. Krish

[email protected]

1-702-714-7001Extn: 9040

Biochemistry Journals

Datta A

[email protected]

1-702-714-7001Extn: 9037

Business & Management Journals

Ronald

[email protected]

1-702-714-7001Extn: 9042

Chemistry Journals

Gabriel Shaw

[email protected]

1-702-714-7001Extn: 9040

Clinical Journals

Datta A

[email protected]

1-702-714-7001Extn: 9037

Engineering Journals

James Franklin

[email protected]

1-702-714-7001Extn: 9042

Food & Nutrition Journals

Katie Wilson

[email protected]

1-702-714-7001Extn: 9042

General Science

Andrea Jason

[email protected]

1-702-714-7001Extn: 9043

Genetics & Molecular Biology Journals

Anna Melissa

[email protected]

1-702-714-7001Extn: 9006

Immunology & Microbiology Journals

David Gorantl

[email protected]

1-702-714-7001Extn: 9014

Materials Science Journals

Rachle Green

[email protected]

1-702-714-7001Extn: 9039

Nursing & Health Care Journals

Stephanie Skinner

[email protected]

1-702-714-7001Extn: 9039

Medical Journals

Nimmi Anna

[email protected]

1-702-714-7001Extn: 9038

Neuroscience & Psychology Journals

Nathan T

[email protected]

1-702-714-7001Extn: 9041

Pharmaceutical Sciences Journals

Ann Jose

[email protected]

1-702-714-7001Extn: 9007

Social & Political Science Journals

Steve Harry

[email protected]

1-702-714-7001Extn: 9042

 
© 2008- 2018 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
Leave Your Message 24x7