alexa Robotics in the MIS Spine Surgery Arena: A New Role to Advance the Adoption of Endoscopic Surgery as the Least Invasive Spine Surgery Procedure | Open Access Journals
ISSN: 2165-7939
Journal of Spine
Make the best use of Scientific Research and information from our 700+ peer reviewed, Open Access Journals that operates with the help of 50,000+ Editorial Board Members and esteemed reviewers and 1000+ Scientific associations in Medical, Clinical, Pharmaceutical, Engineering, Technology and Management Fields.
Meet Inspiring Speakers and Experts at our 3000+ Global Conferenceseries Events with over 600+ Conferences, 1200+ Symposiums and 1200+ Workshops on
Medical, Pharma, Engineering, Science, Technology and Business

Robotics in the MIS Spine Surgery Arena: A New Role to Advance the Adoption of Endoscopic Surgery as the Least Invasive Spine Surgery Procedure

Anthony T. Yeung*

Desert Institute for Spine Care, USA

*Corresponding Author:
Yeung AT
Desert Institute for Spine Care, USA
Tel: +1 602-944-2900
E-mail: [email protected]

Received date: April 26, 2017; Accepted date: May 08, 2017; Published date: May 13, 2017

Citation: Yeung AT (2017) Robotics in the MIS Spine Surgery Arena: A New Role to Advance the Adoption of Endoscopic Surgery as the Least Invasive Spine Surgery Procedure. J Spine 6:374. doi:10.4172/2165-7939.1000374

Copyright: © 2017Yeung AT. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

Visit for more related articles at Journal of Spine

Abstract

The role of robotics is gaining prominence as the technology of the future. In traditional spine surgery, accuracy of hardware placement, selection of ideal size and length of implanted screws and hardware for segmental fixation is desired and important even for experienced surgeons. Hardware placement in tight spaces is especially critical in the cervical and thoracic spine. Robotics will enhance patient safety as well as surgical results, for the protection of patients. By reducing surgical radiation exposure, it also protects patients as well as the surgeon and OR personnel. In endoscopic surgery, improving the accuracy of endoscopic trajectories with image guidance will also bring this aspect of MIS surgery to the surgical mainstream. Robotic techniques are evolving rapidly. Even in their current State of the Art, robotics offer significant advantages to the outpatient spinal surgeon by precise reproducible placement of hardware and endoscopes for minimally invasive approaches.

Keywords

Spine surgery; Endoscopic surgery; Robotics

Introduction

The role of robotics is gaining prominence as the technology of the future. As surgical fusion procedures in spine become more complex and minimally invasive options continue to expand, robotics is touted as the way to help average surgeons become consistently good, or good surgeons becoming better, greatly reducing complications and improving results. In traditional spine surgery, accuracy of hardware placement, selection of ideal size and length of implanted screws and hardware for segmental fixation is desired and important even for experienced surgeons [1]. Hardware placement in tight spaces is especially critical in the cervical and thoracic spine. Robotics will enhance patient safety as well as surgical results, for the protection of patients. By reducing surgical radiation exposure, it also protects patients as well as the surgeon and OR personnel.

In endoscopic surgery, improving the accuracy of endoscopic trajectories with image guidance will also bring this aspect of MIS surgery to the surgical mainstream. There is already extensive experience by surgeons, especially in Asia. Finding the perfect trajectory will help the surgeon target the patho-anatomy of pain in endoscopic surgery. Available imaging from traditional x-rays, Mri’s, CT scans, and 3D reconstruction all help the computer and robot to provide the perfect trajectory needed for endoscopic surgery through mobile tubular retractors. Once the endoscope is directed to the disc, epidural space and the foramen, visualized surgical decompression is facilitated for accurate targeting of the painful patho-anatomy [2]. Anatomic deformities from an aging process can be decompressed and corrected at the same time, using the least invasive tissue sparing techniques that avoid injury to normal anatomy.

In endoscopic surgery, it is well recognized that Intra-operative and immediate post-operative imaging is helpful in MIS spine surgery to confirm that the decompression is accomplished. For fusion and implant placement, especially for percutaneous screw placement and guidance for implants, there is no question that accuracy is desired. Radiation Safety is enhanced due to the adoption of image guidance and less dependence on fluoroscopy. The development of robotics to better standardize cannula and endoscope placement for Endoscopic Percutaneous Surgery will also have great impact on the development and standardization of the least invasive surgical decompression technique that will decrease the need for fusion by 75%, especially if applied early in the “disease” process.

Yeung’s inside-out philosophy and Technique with Endoscopic trajectories incorporating his Artificial Intelligence is programmed into a Robot named Orion by Cardan Robotics. It will facilitate cannula placement for the various target points used in transforaminal endoscopic decompression [3]. A comprehensive compilation of trajectories for the majority of painful degenerative conditions of the lumbar spine is programmed in the Robot. This is guided by lessons learned from Anthony Yeung’s 25 years’ experience applying transforaminal endoscopic treatment of painful degenerative conditions of the Lumbar spine. Transforaminal Endoscopic Decompression, whether inside out, “outside in” or targeted is featured. The concept of Foraminoplasty is differentiated from foraminotomy by Yeung as decompression of the hidden zone of MacNab between the traversing and exiting nerve. The more familiar posterior decompression approach can also be utilized and being developed by other endoscopic minimalists.

Industry Developments Helping Endoscopic Procedures

Multiple systems are currently available, but a surgical suite, incorporating Intra-operative CT scans from a rapid portable CT scanner (O-arm, Airo), aided by a Robotic Arm providing image guidance through Navigation will help facilitate endoscopic development, improve accuracy of instrument placement, insertion of implants, and improve safety and results even for very experienced surgeons. It will shorten the learning curve for novice and less experienced surgeons as well. In endoscopic transforaminal surgery, it will shorten the long learning curve for surgeons who will be able to use it to recognize endoscopic normal and patho-anatomy. It can help with needle placement for diagnostic and therapeutic injections that when effective, will translate to successful endoscopic decompression. The Orion Surgical suite brings all the components together (Figure 1).

spine-orion-surgical-suite

Figure 1: The orion surgical suite incorporating the cardan robot (a) Surgical table, (b) Portable CT scan in OR, (c) Custom table mounted surgical robot, (d) Navigation system, (e) Viewing monitor.

Moreover, the Robot mounted separately and can be used with other existing portable CT scanners such as the O-Arm, and other image guidance systems (Figures 2 and 3).

spine-cannula-trajectories-pathoanatomy

Figure 2: Traditional Imaging Studies, MRI, CT scan and CT 3D Reconstruction are used to determine robot guided target trajectories for ideal needle and cannula trajectories to the pathoanatomy. Endoscopic Trajectories are calculated by the Robot for the ideal skin entry point labeled as the skin window, targeting the patho-anatomy in the foramen known as the foramen window. The mobile cannula is then levered against the ventral facet, used as a lever arm for different angled trajectories to reach the pathoanatomy to be visualized and decompressed endoscopically. The angles and trajectories will be entered by the surgeon calculated by the MRI and CT scan.

spine-Trajectories-ventral-facet

Figure 3: Trajectories use the ventral facet as a target for the robot to use as a lever arm for changing angles targeting the dorsal annulus (red dot), epidural space (purple dot), inlet of the foramen (green dot), sub articular lateral recess, (blue dot), extraforaminal far lateral recess, (brown dot) Illustration courtesy of G Datar.

The Orion system is the first to incorporate robotics for transforaminal endoscopic decompression. It is still in development expected to get US FDA approval in 2017 or 2018 (Figures 4 and 5).

spine-adipose-numerous-painful

Figure 4: The exit zone is the location of numerous painful conditions ideally treatable with transforaminal endoscopic surgery. 11 such conditions have been visualized and treated by Yeung’s 10,000 cases.

spine-Transforaminal-Endoscopic-Surgery

Figure 5: Publication summarizing Yeung’s 25-years and 10,000 procedures experiences in Transforaminal Endoscopic Surgery since 1991.

Discussion

From A Yeung’s experience, the most common treatable conditions accomplished by treating the pain source are as follows:

1. Discogenic pain from toxic annular tears.

2. All types of HNP.

3. Stenosis (both central and foraminal).

4. “Stable” degenerative and isthmic spondylolisthesis.

5. Adjacent level HNP and degeneration.

6. Failed back surgery syndrome (Figures 6 and 7).

spine-dorsal-root-ganglion

Figure 6: The dorsal root ganglion is responsible for pain out of proportion to the imaging study. Imaging can even be “normal” if annular tears leak cytokines causing inflammation of the DRG.

spine-hidden-zone-Mac-Nab

Figure 7: The “hidden zone of Mac Nab is the area between the exiting and traversing nerve that also contains the DRG of the exiting nerve. It is the site of many causes of failed back surgery. Syndrome.

7. Neuropathic pain.

For the accomplished endoscopic surgeon, the need for fusion will be mitigated and decreased approximately 75% by stratifying patient selection, focusing on treating the painful patho-anatomy earlier rather than later in the painful disease process (Figure 8).

spine-edation-fentanyl-versed

Figure 8: Operating under local anesthesia with or without sedation provides an extra layer of safety. If sedation is provided, only 4-5 cc fentanyl and versed is needed.

Endoscopic decompression can identify and treat the variations of normal patho anatomy inherent in patients either as a variation of normal anatomy or as a function of anatomic changes including instability from the aging process.

Case examples of difficult transforaminal approaches that will be facilitated by robotic guidance of ideal trajectories

Examples of painful conditions in the lumbar spine that are amenable to transforaminal endoscopic decompression can be divided into basic and advanced techniques. The robot will facilitate endoscopic decompression for beginner as well as advanced endoscopic surgeons (Figures 9-11).

spine-sequestered-fragment-HNP

Figure 9: This extruded two sequestered fragment HNP requires special trajectories to target the two fragments. To directly target the most migrated fragment, a trajectory to the ventral facet will allow for outside –in foraminoplasty to directly target the more migrated fragment. The partially extruded fragment can then be removed with the “inside –out technique by entering the disc cavity to extract the other fragment whose base inside the disc cavity should also be removed. Other loose fragments will be removed to decrease the incidence of recurrence through the herniation defect. The more migrated fragment may be able to be removed without foraminotomy/foraminoplasty, but there is a chance that the sequestered migrated fragment could be missed if extraction is only from the disc cavity. The outside-in trajectory will assure a targeted approach.

spine-trajectory-ventral-facet

Figure 10: The robot calculates for a 30-degree trajectory to the ventral facet. A targeted method facilitates removal of the pathoanatomy.

spine-evocative-chromo-discography

Figure 11: The needle can slide ventrally under the facet to enter the disc for evocative chromo-discography. A guide pin directs a small cannula to the facet, followed by an awl and drill to fenestrate the ventral facet to the disc that facilitates exposure of the epidural space.

The basic techniques are for intradiscal therapies represented by the following:

1. Toxic annular tears, (intradiscal therapy).

2. Discogenic and axial back pain, (selective endoscopic discectomy (Figures 12-14) and dorsal rhizotomy).

spine-perform-visualized-discectomy

Figure 12: The “medium tang “cannula of the YESS sytem is then inserted down a blunt 2 hole obturator that the YESS endoscope traverses to perform visualized discectomy. The red disc material represents the inflamed extruded herniation, and the light blue white disc is degenerated nucleus removed from the disc cavity.

spine-central-spinal-stenosis

Figure 13: Extreme Case Example #1. An 82-yer-old male with severe foraminal and central spinal stenosis that translaminar decompression would be the choice of 100% of spine surgeons, including A Yeung. The patient elected, however, to undergo a transforaminal endoscopic decompression, when he was told that an open procedure would be an alternative option if his relief were not sufficient even though it would be easier for translaminar decompression. He is one year post- op and pleased with his choice and with his surgical result. Ventral decompression is very effective when technically feasible.

spine-decompressed-traversing-nerve

Figure 14: The decompressed traversing nerve was identified during surgery, and the patient, under local anesthesia was able to report discomfort when the annulus was being resected, but after decompression, pain relief was experienced intra- operatively and post-operative in the recovery room. The annulus was resected under the traversing nerve and visualized free of impingment. The ventral facet of the superior articular process was also removed to decompresed to gain access to the epidural space, also relieving the patient’s symptoms foraminal stenosis causing weakness and intermittent claudication at the follow-up appointment one month later.

3. Multimodal HNP.

4. Failed back surgery syndrome.

5. Neuropathic pain using neuromodulation of the DRG. Advanced techniques are helped by using robotic guidance for ideal cannula trajectories (Figure 15).

spine-degenerative-spondylolisthesis

Figure 15: This patient with a stable grade II degenerative spondylolisthesis only had chronic sciatica from foraminal stenosis. Foraminoplasty resolved the patient’s sciatic pain and numbness. The payer push back for expensive fusion can be reduced 75% in a stratification of indications that focuses on the patho-anatomy and patho-physiology rather than just on the imaging. The disc is already collapsed, but symptoms are from nerve impingement rather than from instability.

Surgeons and Robotics

The surgeon’s level of experience is the most important factor in transforaminal endoscopic surgery (Figure 16).

spine-Robotic-guidance-trajectories

Figure 16: Both basic and advanced techniques will be facilitated by Robotic guidance of trajectories.

Robotics will significantly shorten the learning curve by improving accuracy, and provide patients who want to stage their surgery and have a chance to eliminate fusion as an early surgical option.

Conclusion

Robotic techniques are evolving rapidly. Even in their current State of the Art, robotics offer significant advantages to the outpatient spinal surgeon by precise reproducible placement of hardware and endoscopes for minimally invasive approaches. For endoscopic surgical decompression, especially transforaminal endoscopic surgery, placement of cannulas and endoscopes, the diminished radiation, and eliminating trauma to normal anatomy from surgical approaches pro will revolutionize MIS spine surgery and allow for the least invasive, most effective surgical approach in spine care.

Case examples will demonstrate the technology and Yeung and other endoscopic KOL’s A.I., using robotics. It will help improve results, enhance patient safety, and improve efficacy of outpatient as well as inpatient MIS surgery.

References

Select your language of interest to view the total content in your interested language
Post your comment

Share This Article

Relevant Topics

Recommended Conferences

  • 18th Global Neurologists Annual Meeting on Neurology and Neurosurgery
    Nov 13-15, 2017, Athens, Greece
  • 2nd International Conference on Pediatric Neurology  
    August 31-September 01, 2017 Prague, Czech Republic
  • 12th Global Neurologists Annual Meeting on Neurology and Neurosurgery
    November 16-18, 2017 Lisbon, Portugal

Article Usage

  • Total views: 258
  • [From(publication date):
    June-2017 - Sep 20, 2017]
  • Breakdown by view type
  • HTML page views : 225
  • PDF downloads :33
 

Post your comment

captcha   Reload  Can't read the image? click here to refresh

Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

Agri, Food, Aqua and Veterinary Science Journals

Dr. Krish

[email protected]

1-702-714-7001 Extn: 9040

Clinical and Biochemistry Journals

Datta A

[email protected]

1-702-714-7001Extn: 9037

Business & Management Journals

Ronald

[email protected]

1-702-714-7001Extn: 9042

Chemical Engineering and Chemistry Journals

Gabriel Shaw

[email protected]

1-702-714-7001 Extn: 9040

Earth & Environmental Sciences

Katie Wilson

[email protected]

1-702-714-7001Extn: 9042

Engineering Journals

James Franklin

[email protected]

1-702-714-7001Extn: 9042

General Science and Health care Journals

Andrea Jason

[email protected]

1-702-714-7001Extn: 9043

Genetics and Molecular Biology Journals

Anna Melissa

[email protected]

1-702-714-7001 Extn: 9006

Immunology & Microbiology Journals

David Gorantl

[email protected]

1-702-714-7001Extn: 9014

Informatics Journals

Stephanie Skinner

[email protected]

1-702-714-7001Extn: 9039

Material Sciences Journals

Rachle Green

[email protected]

1-702-714-7001Extn: 9039

Mathematics and Physics Journals

Jim Willison

[email protected]

1-702-714-7001 Extn: 9042

Medical Journals

Nimmi Anna

[email protected]icsonline.com

1-702-714-7001 Extn: 9038

Neuroscience & Psychology Journals

Nathan T

[email protected]

1-702-714-7001Extn: 9041

Pharmaceutical Sciences Journals

John Behannon

[email protected]

1-702-714-7001Extn: 9007

Social & Political Science Journals

Steve Harry

[email protected]

1-702-714-7001 Extn: 9042

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords