Make the best use of Scientific Research and information from our 700+ peer reviewed, Open Access Journals that operates with the help of 50,000+ Editorial Board Members and esteemed reviewers and 1000+ Scientific associations in Medical, Clinical, Pharmaceutical, Engineering, Technology and Management Fields.
Meet Inspiring Speakers and Experts at our 3000+ Global Conferenceseries Events with over 600+ Conferences, 1200+ Symposiums and 1200+ Workshops on
Medical, Pharma, Engineering, Science, Technology and Business

Second Generation DES: Better Option in Treatment ISR

Hristova N*, Trendafilova D and Jorgova J

University Hospital “St Ekaterina”, Clinic of Cardiology and Cardiosurgery, 52 A Bul. Pencho Slavejkov, 1431 Sofia, Bulgaria

*Corresponding Author:
Nadezhda Hristova
Cardiology clinic, University hospital “St. Ekaterina”
bul. Pencho Slaveikov 52 A, Sofia, Bulgaria
Tel:
+359 895418911; +35929549057
E-mail: [email protected]

Received Date: March 17, 2014; Accepted Date: April 28, 2014; Published Date: April 30, 2014

Citation: Hristova N, Trendafilova D, Jorgova J (2014) Second Generation DES: Better Option in Treatment ISR. J Vasc Med Surg 2:133. doi: 10.4172/2329-6925.1000133

Copyright: © 2014 Hristova N, et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

Visit for more related articles at Journal of Vascular Medicine & Surgery

Abstract

The development of an effective strategy for treatment of in-stent restenosis after BMS placement has been found to be extremely complicated. The therapeutic purpose for many patients is achieved with the implantation of DES – an option which is still not investigated and studied enough. 152 patients with implanted drug-eluting stents (different generations) for severe in-stent restenosis were followed up for a period of 9 years in the department of cardiology of University Hospital “St. Ekaterina”. Patients were divided into two groups – 131 patients with implanted first generation DES, and 21 patients – with second generation DES. Patients were followed up clinically (reversed angina, MI, emergency CABG, death), EchoCG and/or ECG stress test. Patients with angina pectoris and/or decreased LV function were assessed by conventional or CT angiography. Serious complications were not observed. 9 patients were with significant in-stent proliferation, and the others were with patent stents. Implementation of DES for treatment of in-stent restenosis is an established method, because of its reliability and safety with low percentage of complications.

Keywords

In-stent restenosis; Drug-eluting stent

Introduction

In-stent restenosis (ISR), lack of treatment for chronic total occlusions and diffuse coronary artery disease in diabetics are fundamental challenges in interventional cardiology. Restenosis after bare metal stent (BMS) implantation has been considered to be the most significant problem in coronary interventional treatment [1]. Proven risk factors are: small diameter of the vessel, previous restenosis, long stented segments, ostial lesions, and diabetes mellitus [2]. Several techniques and strategies for the treatment of ISR have been used historically – atherectomy, cutting baloon, brachytherapy, POBA, DES, CABG [3,4]. Each one demonstrated some success but the best approach remains unsettled [5]. Drug - eluting stents (DES) have dramatically reduced the rates of restenosis and target lesion revascularization compared with BMS [6,7]. 12 years after the first DES implantation the “perfect stent” is not found yet, but the variety of stents and cumulated experience, especially after the introduction of the first generation DES, approved them as a safe and reliable method for treating of in-stent restenosis in patients with different risk profile. This review will focus on the treatment of patients with ISR with different generation DES implantation.

Aim

To evaluate and analyse early and late results in patients with instent restenosis treated with different generation’s drug-eluting stent for a period of 2 years.

Methods

This was a retrospective study of 152 patients with implanted drugeluting stents (different generations) for significant in-stent restenosis, who were followed up for a period of 9 years – from January 2004 – up to December 2012 in the department of cardiology of University Hospital “St. Ekaterina”.

Patients were divided into two groups:

I group - 131 patients with impalnted first generation DES - sirolimus- eluting stent (SES), paclitaxel – eluting stent (PES), tacrolimus – eluting stent

II group – 21 patients with implanted second generation DES – everolimus – eluting stent (EES), biolimus A - eluting stent (BES).

Medical therapy after the procedure ( minimum 1 year) included dual antiplatelet therapy, statin and standard antianginal agents.

All of the patients were followed up for early or late manifestation of reversed angina, MI, emergency CABG, death, repeat revascularization, LV function assessment. Physical examination, echocardiography and/ or ECG stress test (according to indications and contraindications) were performed for each patient. Patients with angina pectoris and/or decreased LV function were checked by conventional angiography or CT angiography (Table 1).

Follow up I group – 131pts II group – 21pts
Coronary angiography 41 out of 131 / 31%/ 1 out of 21 / 5%/

Table 1: Angiographic follow up.

Patients were between 34 and 87 years old. 80% from the studied population were male and 20% - female (Figure 1).

vascular-medicine-surgery-demographic-characteristics

Figure 1: Demographic characteristics.

The main clinical characteristics of each patient are summarized in Table 2. In both groups prevail patients with stable angina with no severe heart failure. The percentage of patients with chronic renal insufficiency is relatively low (none in group II). There are no patients after surgical revascularization in the second group.

  I group – I generation DES – 131 pts II group – II generation DES - 21pts
Stable angina 87 out of 131 / 66%/ 8 out of 21 / 38%/
Unstable angina 42 out of 131 / 32%/ 9 out of 21 / 29%/
Previous CABG 9 out of 131 / 7%/ 0 out of 21
EF>40% 114 out of 131 / 87%/ 20 out of 21 / 95%/
EF<40% 17 out of 131 / 13%/ 1 out of 21 / 5%/
Heart failure III NYHA 12 out of 131 / 9%/ 1 out of 21 / 5%/
Chronic renal insufficiency I stage 7 out of 131 / 5%/ 0 out of 21

Table 2: Clinical characteristics.

Highest is the frequency of arterial hypertension and dyslipidemia, followed by diabetes mellitus and smoking concerning the risk factors for ischemic heart disease (Table 3).

  I group – 131pts II group – 21pts
Daibetes mellitus 51 out of 131 / 39%/ 6 out of 21 / 29%/
Arterial hypertension 112 out of 131 / 85%/ 21 out of 21 / 100%/
Obesity 45 out of 131 / 34%/ 3 out of 21 / 14%/
Smoking 47 out of 131 / 36%/ 5 out of 21 / 24%/
Dyslipidemia 102 out of 131 / 78%/ 18 out of 21 / 88%/
Family history 43 out of 131 / 33%/ 7 out of 21 / 33%/

Table 3: Risk factors.

PCI was performed according to standard methods via a radial or femoral approach using a 6 Fr guiding catheter. Treatment with clopidogrel was started prior to the procedure. Following sheath insertion, unfractionated heparin was administered as bolus doses of 10 000 U. Analysis of the angiographic characteristic of the treated vessels shows that the target vessel was LAD in both groups (56% in group I and 48% in group II), followed by Cx in group I (28%) and by RCA (33%) in group II (Figure 2). There were no left main artery angioplasty. Regarding the morphological pattern prevailed long diffuse lesions in both groups. In group I more occlusions were treated. The culprit lesion ranged from 70% to 100% diameter stenosis by quantative coronary angiography. The mean lesion length was 28 mm in both groups. Predilatation was done in 85% of the cases in both groups. As per the standard protocol high pressure postdilatation was performed in both groups. Only 2 patients from the first group were with implanted 2.75 mm stents. DES diameter varied from 3.00 to 4.00mm for all of the other patients.

vascular-medicine-surgery-angiographic-characteristics-vessels

Figure 2: Angiographic characteristics – treated vessels.

Results

Patients were followed up for early and late complications. Clinical condition, lab results, ECG, EchoCG of all of the patients was verified after the procedure. It was observed improvement in clinical status, ejection fraction, and physical capacity after DES placement for severe in-stent restenosis.

A few complications were registered. Acute mild complications were observed in 4 patients (from the first group) – 2.6 % (Table 4). There were no acute serious complications (MI, emergency CABG, death) registered. No acute stent thrombosis was registered.

Long – term all the patients were followed up for 24 months (± 6 months) for reversed angina, MI, emergency CABG, death, repeat revascularization, LV function assessment (Figure 3). 42 patients (28%) were assessed by conventional coronary angiography because of recurrent angina pectoris. 9 (6.8 %) of the examinations revealed significant in-stent proliferation, as all of them were with implanted DES from the first generation. The others – showed patent stents, with no significant proliferation. No severe complications were registered in either group.

vascular-medicine-surgery-follow-up-complications

Figure 3: Follow-up and complications – 24 ± 6months.

Subanalysis of these 9 patients marked that the length ot treated segment was >27 мм. 8 of them were with implanted paclitaxel-eluting stent, 1 patient – with implanted tacrolimus- eluting stent.

In 5 (out of 9) of the patients the angiography revealed in-stent occlusion, and in 4 (out of 9) – in-stent restenosis. From the 5 patients with in-stent occlusion 3 were referred for CABG. The other 2 (out of 5) were recommended for medical treatment because of low class angina and good collateral circulation. Two (out of 4) from the patients with ISR were treated with balloon angioplasty with drug- eluting balloon. The other 2 patients with ISR were referred for CABG.

Discussion

DES implantation is an alternative method in treating ISR of BMS with low rate of restenosis and late thrombosis [8]. SES do not show any difference concerning the rate of ISR and stent thrombosis when compared with second generation DES in our study. First generation PES have higher rate of ISR and stent thrombosis compared to II generation DES, pointing Taxus-Liberte analogs. The length of the stented segment shows correlations with the rate of the ISR. Our results demonstrate correlation to the latest interventional randomized controlled trials and studies concerning the use of first and second generation DES in treating ISR [9-12]. With the development of the new DES technologies there are a lot of comparisons and probably new conclusions to be made. Dedicated studies focused on the results of coronary surgery for patients with ISR remain very limited. Some investigators suggest that saphenous vein grafts have an unacceptably high incidence of failure among these patients and the use of arterial conduits should be considered to improve long-term results [13].

Conclusion

ISR remains an unresolved issue after BMS implantation especially when used in complex lesions. Implementation of DES for treatment of in-stent restenosis is a leading method, because of its reliability and safety with a very low percentage of complications and significantly reduced clinical and angiographic restenosis rates in selected patients.

Limitations

Only patients with clinical data of restenosis were checked; small group of patients were assessed by conventional coronary angiography; no IVUS controlled angiography was made to assess the grade of neointimal proliferation.

References

Select your language of interest to view the total content in your interested language
Post your comment

Share This Article

Relevant Topics

Article Usage

  • Total views: 11690
  • [From(publication date):
    April-2014 - Oct 19, 2017]
  • Breakdown by view type
  • HTML page views : 7900
  • PDF downloads :3790
 

Post your comment

captcha   Reload  Can't read the image? click here to refresh

Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

Agri, Food, Aqua and Veterinary Science Journals

Dr. Krish

[email protected]

1-702-714-7001 Extn: 9040

Clinical and Biochemistry Journals

Datta A

[email protected]

1-702-714-7001Extn: 9037

Business & Management Journals

Ronald

[email protected]

1-702-714-7001Extn: 9042

Chemical Engineering and Chemistry Journals

Gabriel Shaw

[email protected]

1-702-714-7001 Extn: 9040

Earth & Environmental Sciences

Katie Wilson

[email protected]

1-702-714-7001Extn: 9042

Engineering Journals

James Franklin

[email protected]

1-702-714-7001Extn: 9042

General Science and Health care Journals

Andrea Jason

[email protected]

1-702-714-7001Extn: 9043

Genetics and Molecular Biology Journals

Anna Melissa

[email protected]

1-702-714-7001 Extn: 9006

Immunology & Microbiology Journals

David Gorantl

[email protected]

1-702-714-7001Extn: 9014

Informatics Journals

Stephanie Skinner

[email protected]

1-702-714-7001Extn: 9039

Material Sciences Journals

Rachle Green

[email protected]

1-702-714-7001Extn: 9039

Mathematics and Physics Journals

Jim Willison

[email protected]

1-702-714-7001 Extn: 9042

Medical Journals

Nimmi Anna

[email protected]

1-702-714-7001 Extn: 9038

Neuroscience & Psychology Journals

Nathan T

[email protected]

1-702-714-7001Extn: 9041

Pharmaceutical Sciences Journals

John Behannon

[email protected]

1-702-714-7001Extn: 9007

Social & Political Science Journals

Steve Harry

[email protected]

1-702-714-7001 Extn: 9042

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords