alexa
Reach Us +44-1235425476
Single Photon Emission Computed Tomography Scan as a Diagnostic Tool in Children with Cerebral Palsy Treated with Human Embryonic Stem Cells | OMICS International
ISSN: 2155-9619
Journal of Nuclear Medicine & Radiation Therapy

Like us on:

Make the best use of Scientific Research and information from our 700+ peer reviewed, Open Access Journals that operates with the help of 50,000+ Editorial Board Members and esteemed reviewers and 1000+ Scientific associations in Medical, Clinical, Pharmaceutical, Engineering, Technology and Management Fields.
Meet Inspiring Speakers and Experts at our 3000+ Global Conferenceseries Events with over 600+ Conferences, 1200+ Symposiums and 1200+ Workshops on Medical, Pharma, Engineering, Science, Technology and Business
All submissions of the EM system will be redirected to Online Manuscript Submission System. Authors are requested to submit articles directly to Online Manuscript Submission System of respective journal.

Single Photon Emission Computed Tomography Scan as a Diagnostic Tool in Children with Cerebral Palsy Treated with Human Embryonic Stem Cells

Geeta Shroff1*, Barthakur JK2, Parul Mohan3 and Harsh Mahajan4

1Nutech Mediworld, New Delhi, India

2Department of Statistics, Retired Additional Secretary, Ministry of Home Affairs, Government of India

3Department of Nuclear Medicine, Mahajan Imaging Centre,Fortis Flt. Lt. Rajan Dhall Hospital, New Delhi, India

4Mahajan Imaging Centre, New Delhi, India

*Corresponding Author:
Geeta Shroff
Director, Nutech Mediworld, H-8
Green Park Extension, New Delhi-110016, India
Tel: +91 11 26565548
Fax: +91 11 46067841
E-mail: [email protected]

Received date : March 16, 2015; Accepted date : April 11, 2015; Published date : April 16, 2015

Citation: Shroff G, Barthakur JK, Mohan P, Mahajan H (2015) Single Photon Emission Computed Tomography Scan as a Diagnostic Tool in Children with Cerebral Palsy Treated with Human Embryonic Stem Cells. J Nucl Med Radiat Ther 6:223. doi:10.4172/2155-9619.1000223

Copyright: © 2015 Shroff G, et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.



Visit for more related articles at Journal of Nuclear Medicine & Radiation Therapy

Abstract

Introduction: Cerebral palsy (CP) is caused by abnormalities in the developing brain leading to an impairment of muscle coordination and movement control in the body. Neonatal hypoxic-ischemic brain injury and hypoxic ischemic encephalopathy (HIE) are major causes of CP. Neurodegenerative disorders can be treated with human embryonic stem cells (hESC). Magnetic resonance imaging (MRI), positron emission tomography and single photon emission computed tomography (SPECT) scan are some of the imaging modalities for CP, but among all SPECT scan is more sensitive in detecting abnormalities in the brain. SPECT scan is an effective tool for the detection of cerebral blood flow, cerebral impairment and local brain metabolism. The present study was conducted to evaluate the diagnostic modality of SPECT scan that can assess the patient with CP before and after hESC therapy.
Methodology: The study included the patients with CP for whom SPECT scan was performed before and after the therapy. Technetium-hexa methyl propylene aminoxime (Tc-HMPAO) SPECT scan was analyzed to assess the number of hypoperfused lesions/ areas in the brain and the percentage of improvement by hESC treatment. The patients were scored clinically using GMFCS scores.
Results: Overall, 88 patients aged 2 months to 18 years with clinical manifestations of CP had SPECT scan performed before and after the therapy. The total treatment days varied from 31 to 310 days. All the subjects showed improvement in SPECT scan. Majority of subjects (n=58) had significant SPECT scan (>60%) change, followed by moderate SPECT scan (>30% <60%) change in 15 subjects, mild scan (>10% <30%) change in 3 subjects. These patients also showed a clinical improvement as reflected in their GMFCS scores.
Conclusion: SPECT scan can be a crucial diagnostic modality to assess patients with CP.

Keywords

Cerebral palsy; Human embryonic stem cells; SPECT scan; GMFCS

Introduction

Cerebral palsy (CP) is a neurological disorder caused by abnormalities in the developing brain of infants and children. CP leads to an impairment of muscle coordination in the body and movement control [1]. The worldwide prevalence of CP is 1.5 to 4 per 1,000 live births [2].

Developmental brain abnormalities, genetic conditions, traumatic or infectious disorders, or hypoxic-ischemic insult are some of the causes of CP [3,4]. The patients experience loss of oligodendrocytes and myelin in the brain [5]. The distribution of the lesion in the brain gives the clinical picture of CP. There are no specific diagnostic tests for CP. Magnetic resonance imaging (MRI), positron emission tomography [6] and single photon emission computed tomography (SPECT) scan are some of the imaging modalities for CP [4], but among all SPECT scan is more sensitive in detecting abnormalities in the brain [7,8].

SPECT scan is a functional imagining modality that can provide valuable information for the diagnosis of CP [4]. SPECT scan is an effective tool for the detection of brain hypoperfusion, cerebral blood flow, cerebral impairment and local brain metabolism [9-11]. According to Lee et al. brain SPECT scan is helpful in diagnosis of CP and can detect abnormalities in cortical, sub cortical nuclei and cerebellar regions. Okumura et al. suggested that SPECT could also be useful for the diagnosis of kernicterus in CP patients [12].

SPECT using N-isopropyl-p-[123I]-iodoamphetamine is a useful tool for neurological assessment in CP patients [13]. SPECT scan can indicate improvement before the clinical changes are manifested and detect changes at the molecular level. The extent of perfusion is reflected with extent of tracer uptake. A reduced tracer uptake in these regions represents hypoperfused areas of the brain; an increased tracer uptake represents hyperperfusion while absence of tracer uptake represents the areas with no perfusion. SPECT scan reflects the extent of improvement in perfusion among the patients and regenerative potential of hESCs [9-11].

Although many studies have been published related to brain perfusion abnormalities in various neurological disorders [1,4,14], there is negligible literature concerning the interval changes in perfusion in the cerebral cortical functional areas, before and after the therapy.

The present study was conducted to evaluate the diagnostic modality of SPECT scan. The patients with CP were treated with human embryonic stem cell (hESC) therapy as described previously [15].

Methodology

The patients with clinical manifestations of CP underwent brain SPECT scan before and after hESC injection. The study was conducted from Oct 2007 to July 2013 in Nutech Mediworld, New Delhi, India. The study design and the detailed techniques have been elaborated in our previous study [15,16]. Briefly, the study consisted of four treatment phases (T1,T2,T3,T4) separated by a gap phase of 4-6 months. After CP diagnosis, the patients were tested with 0.25 mL hESC injected subcutaneously for any hypersensitivity reactions.

During first treatment phase (8 weeks) 0.25 mL dose containing <4 million hESCs were administered through intramuscular (i.m) (for priming) route once daily and 1 mL dose containing of <16 million cells hESC was administered twice every 7 days through intravenous (iv) route (to facilitate faster transplantation and migration of the hESCs to the affected area).

Each patient also received a dose of hESCs by caudal route repeated every 5-14 days to ensure they reach the spinal fluid and regenerate the spinal cord and allow deep muscles to repair.

The patients entered second and third treatment phase (T2 and T3) after a gap period of 3-6 months, where the same dosage regime was administered. Both T2 and T3 lasted for 4 weeks and were separated by a gap phase of 3-6 months. After a gap period of 6-12 months T4 was performed with the increased IV dose of hESC by 1 mL.

The efficacy of hESC therapy was assessed by evaluating the change in SPECT scan at the end of each treatment phase.

Nutech Mediworld is a GCP (good clinical practice) compliant certified center. The treatment carried out at the centre is approved by the Independent Ethics Committee (IEC). The Institutional Committee of Stem Cell Research and Therapy (IC-SCRT) reports all the work with respect to embryonic stem cells to National Apex Body [16].

The cell lines cultured and maintained as per our proprietary in-house patented technology in a GMP (good manufacturing practice), GLP (good laboratory practice) and GTP (good tissue practice) certified Nutech Mediworld laboratory (Patent-WO 2007/141657A PCT/1B 2007 Published 13 December 2007). The procedures followed were in accordance with the ethical standards laid down and in conformance with the Helsinki Declaration of 1975, as revised in 2008 [15,17].

SPECT scan

Preparation of 99mTc-HMPAO

Technetium-hexa methyl propylene aminoxime (Tc-HMPAO) SPECT scan was analyzed to assess the number of hypoperfused lesions/areas in the brain and the percentage of improvement by hESC treatment. A HMPAO kit was purchased from Ceretec™, Amersham Ltd., Amersham, UK.

Fresh elutes of technetium (99mTc) were used to prepare 99mTc-HMPAO according to the manufacturer's instructions and recommendations. In brief, 1110–2960 MBq of 99mTcO4 in 5 mL of saline were added to a freeze dried Exametazime kit (Ceretec™) to produce 99mTc-HMPAO. Tc HMPAO was eluted everyday by IBA generator in the nuclear medicine department (Fortis Hospital, Vasant kunj, Delhi).

SPECT acquisition

Brain SPECT scan was performed 20 minutes after the intravenous administration of 99mTc-HMPAO into antecubital vein of the patients in a quite dimly lit room. A tomographic camera (Millinieum MG, GE) equipped with a low-energy high resolution parallel hole collimator was used. After 15-120 minutes, the patient was placed in a supine position in order to ensure that orbito-meatal line (OML) is positioned vertically, centered in the field of view.

The SPECT scan (Millennium MG, GE) was performed before or within 7 to 10 days of hESC therapy initiation and thereafter at the end of the treatment.

Gamma camera imaging

Each scan was performed using a dual headed gamma (γ) camera of 8.5 mm crystal thickness equipped with a dual Digital Correlated Signal Enhancement (CSE) detector and 55 ke- 540 keV energy window connected to a computer.

Images were acquired in a step-and-shoot mode (128 projections, 35 sec/projection) on a 128x128 matrix and the photo peak was centered at 140 keV with a symmetrical 10% window. Images were reconstructed using the filtered back projection technique. No attenuation correction was applied.

SPECT scan analysis

We applied the NeuroGam™ software on the reconstructed data, for the evaluation of brain perfusion in specific areas in the left and right hemispheres. NeuroGam™ is a comprehensive package for the display and quantification of functional brain studies, allowing differential analysis of activation studies by using an automatic registration algorithm.

This software applies an affine co-registration by blocks of data defined in the Talairach space. Each hemisphere is subdivided in six rectangular volumes which undergo a specific affine transformation to fit the Talairach atlas. There is no additional smoothing performed. The method allows quantitative and qualitative comparison of sequential brain images on the same patient and a given patient (either with a normal database or disease specific database), creation of normal and disease specific database and, the quantitative analysis of brain images according to predefined Broadmann functional areas (Brodmann areas 1,2,3-primary somatosensory cortex; area 4-primary motor cortex, area 17-primary visual cortex and areas 41 and 42-primary auditory cortex).

Image processing and interpretation

SPECT scans were interpreted by a certified nuclear medicine physician with an extensive experience in brain SPECT scans interpretation. We used a previously described approach for interpreting functional imaging scans such as grey color representing normal regions in the brain; red, pink and white representing above normal regions; while green, light/dark blue, black representing hypoperfused regions [15].

Patients showing 60-90% changes were considered to have significant improvement, 30-60% changes moderate improvement and 10-30% changes mild improvement. In addition, the evaluation of the motor functions of cerebral palsy cases was done with GMFCS, which is an international parameter with grades 5→1 in BAD→GOOD direction.

Results

Study Patients

The data of 88 patients were analyzed, of which 24 subjects were females. The age of the patients varied from 2 months-18 years. The total treatment days varied from 31 to 310 days. The demographic details of the patients is given in Table 1.

Characteristics N
Gender  
Male 23
Female 64
Origin  
India 81
Abroad 7
Age  
Up to 2 years 11
2-5 years 27
5-10 years 25
10-20 years 25

Table 1: Demographic details of the patients.

Outcome

All the subjects showed an improvement in SPECT scan. Majority of subjects (n=58) had significant SPECT scan (>60%) change, followed by moderate SPECT scan (>30% <60%) change in 15 subjects, and mild scan (>10% <30%) change in three subjects (Figure 1).

nuclear-medicine-radiation-SPECT-scan

Figure 1: Change in SPECT scan at the end of the treatment.

None of the subjects showed deterioration. The SPECT scan report of one patient is illustrated in Figures 2A and 2B.

nuclear-medicine-radiation-Cerebral-Palsy

Figure 2a: SPECT Scan of Cerebral Palsy Patient Showing Hypoperfused Regions before receiving hESCs Therapy.

nuclear-medicine-radiation-Improved-perfusion

Figure 2b: SPECT Scan of a Cerebral Palsy Patient Showing Improved Perfusion (Reduced Black Areas) after receiving hESCs Therapy.

All the patients were assessed clinically using GMFCS scores before and after the therapy. The improvement in SPECT scan after the therapy was also reflected in the improvement in GMFCS scores of the patients after the therapy. GMFCS Score of the patients at start and end of each treatment phase Table 2.

  GMFCS SCORE
  1 2 3 4 5
Baseline (N=88) 1 12 14 21 40
End of T1 6 31 36 14 1
Start of T2 (N=65) 1 22 29 13 0
End of T2 7 34 17 7 0
Start of T3 (N=38) 3 17 11 7 0
End of T3 11 18 6 3 0
Start of T4 (N=15) 1 8 6 0 0
End of T4 5 7 3 0 0

Table 2: GMFCS Score of the Patients at Start and End of Each Treatment Phase.

Discussion

In the present study the efficacy of hESC therapy was evaluated based on the grade in SPECT scan and change in GMFCS scores. An improvement in SPECT scan was observed in CP patients after hESCs therapy. The improvement was reflected by a reduced hypoperfusion in the SPECT scan of the brain. A significant change in SPECT scan (>60%) was observed in majority of subjects. This improvement was also reflected in GMFCS scores change, where GMFCS score was reduced from 5 (BAD) to 1 (GOOD) in majority of the patients at the end of the treatment. These results indicate that SPECT scan is a useful tool in the assessment of patients with CP and treatment progression with hESCs.

SPECT is a physiological imaging technique that detects metabolic and neurochemical changes in neurogenerative disorder [14]. SPECT is an aid that may help in diagnosing the disease at an early stage. According to Wang et al. combination of SPECT with other techniques such as olfaction test and transcranial sonography may result in higher accuracy of neurogenerative disease diagnosis [14]. In our study, the CP patients were evaluated for recovery using SPECT scan. A reduced tracer uptake in the hypoperfused regions of the brain can be detected by the SPECT scan. hESCs migrated to the affected area and the improvement in perfusion is evident from the extent of improvement in the SPECT scan. At the end of therapy 65.9% (N=58) subjects showed >60% of improvement in SPECT scan. This improvement was reflected clinically in the GMFCS scores.

In the present study, SPECT imaging was performed after injection of radiotracer, TC-99m HMPAO. The radiotracer, 99mTc labeled HMPAO SPECT is the most widely used radiotracers for imaging cerebral blood flow [18]. This radiotracer is small, lipophilic and stable that circulates to brain with the blood, readily passes through the BBB and is metabolized and retained intracellularly. The brain distribution of HMPAO reflects regional brain perfusion [19,20]. A normal SPECT scan with 99mTc-HMPAO shows more intense perfusion in the cerebellum [21]. 99mTc-HMPAO is more preferred radiotracer than 99mTc ethyl cysteinate dimer (ECD) [7].

In relation to clinical outcomes, SPECT scans have false positive and false negative rate, hence more studies to measure the accuracy of a diagnostic test are needed [22]. Also, diagnostic accuracy statistics of SPECT should also be examined for insight into the common rates of false positive and negative tests [23]. Valkama et al. in their study reported 100% sensitivity and 67% specificity of SPECT scan in predicting moderate or severe CP. The perfusion defects in CP were predicted with sensitivity of 80%, specificity of 70% and accuracy of 74% [24]. A high diagnostic sensitivity of SPECT scan shows that costly false-negative SPECT scans are rare [23].

Neuroimaging studies have increased our understanding of the brain abnormalities in the patients with CP [25]. SPECT brain perfusion imaging is more valuable and sensitive than X ray, CT or MRI as it can detect more brain lesions compared to other morphologic modalities [7,8]. MRI detects only damage that occurred when flow of cerebral blood is reduced to <10 ml/100 g of tissue/1 min, while SPECT scan have ability to detect hypoperfusion areas secondary to neuronal loss [24]. MRI and CT are less informative due to common problems associated with them such as inappropriate and inconsistent morphologic, radiologic and, pathologic findings and their uncertain relationship to the time estimation of brain injury [25].

Abdel Dayem et al. in their study reviewed the data of 228 patients of age 11-88 years with traumatic brain injury. SPECT scan revealed focal area hypoperfusion in 77% of the patients. Of 41 patients who had normal CT and negative loss of consciousness, 28 patients were reported to have abnormal brain SPECT scan [7]. Abu Judeh et al. observed brain perfusion abnormalities detected by SPECT scan in patients who previously had normal X ray CT for brain lesions. The incidence of abnormal brain perfusion was greater in the patients who were imaged early at <3 months post injury than those imaged delayed at >3 months from date of accident. Hence, SPECT scan must be performed at an early stage [8]. In a study by Lee et al., cerebellar hypoperfusion was reported in 20 (N-52) CP patients as demonstrated by SPECT scan, while MRI detected cerebellar atrophy only in one patient [4]. Ryu et al. compared SPECT scan and MRI findings in assessments of abnormalities in patients with autism. SPECT scan and MRI were performed for 23 patients, of which 20 patients had abnormal SPECT scan revealing decreased perfusion in the cerebellar regions, while all patients had normal MRI without evidence of cerebellar abnormalities. Hence, SPECT scan is more sensitive in detecting abnormalities than MRI [23].

Stem cells follow a chain of reactions to replace the damaged neurons involving both exogenous and endogenous neurons, glial cells, and endothelial cells. These cells act synergistically to repair brain damage [26]. Various studies demonstrated the differentiation of hESCs derived progenitor cells to the site of brain injury [27-29], that raised the hope that hESC therapy can be developed to treat central nervous system related disorders [30]. In our previous study, we have observed successful treatment of the CP patients with hESCs therapy [15]. It is possible that the hESCS injected in our patients, could have permeated parenchyma via blood brain barrier (BBB) and migrated to the affected regions, as the size of the hESCs were <1 μm. These cells might have differentiated into neural cells and replaced the damaged tissue [15]. In another paper the co-relation between SPECT scan and GMFCS has been done. We have observed a lot of cognitive improvement that was not determined by GMFCS [15,16].

In the present study, etiology of CP was hypoxia prenatally, especially at delivery (traumatic). hESCs were administered through i.m, i.v and caudal routes. We observed that our patients showed an improvement in SPECT scan earlier than the clinical improvement. This might be due to the fact that hESCs need time for regeneration and differentiation and become functional. This was also the primary reason for gap phase of 3-6 months between the successive treatment phases in our hESC therapy protocol. Our results suggest that the application of NeuroGam processing protocol offers a more detailed and objective evaluation of regional cerebral blood flow and may contribute to a better discrimination in monitoring any treatment response in patients. The age of the patients was between 2 months-18 years and total treatment days varied from 31 to 310 days. In such a short duration of time, it is highly unlikely that the cells of the brain matured and healed naturally, hence we could assume that that improvement in motor function was due to stem cell therapy. None of our patient had reported deterioration and their condition was stable.

The results of the present study were derived from a small cohort of patients, and need to be replicated in a larger sample population. Moreover, the comparison of brain perfusion with clinical and neuropsychological parameters in neurological patients needs further investigation.

Conclusion

The extent of improvement in patients treated with hESCS was carefully monitored with SPECT scan and GMFCS scores. Brain SPECT scan may be extremely useful tools in monitoring the treatment response to hESCs therapy in patients of CP. Further studies must be conducted to examine the diagnostic value SPECT scans and to evaluate the possible effects of hESC therapy. SPECT imaging helps in understanding the differential diagnosis and the disease progression. SPECT scan may be used as a prognostic tool for the detection of the extent of improvement in perfusion in the brain. SPECT scan can be used as an effective diagnostic modality to assess the patient with CP before and after hESCS therapy.

Conflict of Interest

The authors do not have any conflict of interest.

Acknowledgements

The authors acknowledge Dr. Anupama Gupta (Pediatrician, Max Hospital, Saket, New Delhi), the staff of Nutech Mediworld, all patients and their parents. The authors also acknowledge Knowledge Isotopes Pvt. Ltd (http://www.knowledgeisotopes.com) for writing support.

References

Select your language of interest to view the total content in your interested language
Post your comment

Share This Article

Article Usage

  • Total views: 12967
  • [From(publication date):
    May-2015 - Nov 14, 2019]
  • Breakdown by view type
  • HTML page views : 9146
  • PDF downloads : 3821