alexa
Reach Us +44-1647-403003
Strangulated Male External Genitalia by Steel Ring: A Safe Rescue Case Report | OMICS International
ISSN: 2165-7920
Journal of Clinical Case Reports
Make the best use of Scientific Research and information from our 700+ peer reviewed, Open Access Journals that operates with the help of 50,000+ Editorial Board Members and esteemed reviewers and 1000+ Scientific associations in Medical, Clinical, Pharmaceutical, Engineering, Technology and Management Fields.
Meet Inspiring Speakers and Experts at our 3000+ Global Conferenceseries Events with over 600+ Conferences, 1200+ Symposiums and 1200+ Workshops on Medical, Pharma, Engineering, Science, Technology and Business
All submissions of the EM system will be redirected to Online Manuscript Submission System. Authors are requested to submit articles directly to Online Manuscript Submission System of respective journal.

Strangulated Male External Genitalia by Steel Ring: A Safe Rescue Case Report

ZeHong Lu* and KuanHsun Huang

Department of Urology, Medical College and Hospital, National Cheng Kung University, Tainan, Taiwan

Corresponding Author:
ZeHong Lu
Department of urology, Medical College and
Hospital, National Cheng Kung University, Tainan, Taiwan
Tel: +886-6-275-757
E-mail: [email protected]

Received date: June 10, 2016; Accepted date: July 15, 2016; Published date: July 20, 2016

Citation: Lu Z, Huang K (2016) Strangulated Male External Genitalia by Steel Ring: A Safe Rescue Case Report. J Clin Case Rep 6:836. doi:10.4172/2165-7920.1000836

Copyright: © 2016 Lu Z, et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

Visit for more related articles at Journal of Clinical Case Reports

Abstract

We reported strangulated male external genitalia by three steel rings for 24 hours. It is difficult to manage without adequate device and some rescue devices may bring possible iatrogenic injury to genital organ. Steel ring was removed by hydraulic cutter instead of angle grinder which was applied in our previous experience and mentioned by literature. Angle grinder may bring cutting or thermal injury to patient or medical staff. It may be safer method to rescue strangulation with hydraulic cutter instead of angle grinder especially in those patients with blood borne disease. However, management may be individualized for difference material and shape of constricting device.

Keywords

Strangulation; Male external genitalia; Steel ring; Hydraulic cutter; Iatrogenic injury

Introduction

Strangulated male external genitalia by steel ring is hard to remove soon due to the lack of suitable device in hospital. However, delayed removal may induce genital organ necrosis or irreversible damage. We announced a safe rescue case report, and reviewed literature for find out a possible safe method for those conditions.

Case Report

32 y/o male with the underlying disease of Human Immunodeficiency Virus (HIV) infection presented at our Emergency Room (ER) for help on a weekday night. Three steel rings stragulated his external genitalia (Figure 1). It accompanied with pain, local heat and edematous change over scrotal wall. He denied difficulty voiding. He applied rings over scrotum since about 24 hours ago. Adequate pain control with intramuscular injection (IM), nonsteroidal antiinflammatory drug (NSAID) was performed immediately. It cannot be removed manually with lubrication.

clinical-case-reports-External-genitalia

Figure 1: External genitalia strangulation.

Ioannis Efthimiou et al. [1] had reported a successful steel ring removal by angle grinder under general anaesthesia. In our hospital, we had a similar case about several months ago, and angle grinder was performed by fireman with protection penis by gauze and pouring cold normal saline for preventing thermal injury by urologist in our ER. Ring was removed smoothly without obvious injury at that time. However, using angle grinder accompanied with high risk of cutting to patient, medical staff or even ambulancemen. Potential thermal injury by sparking during cutting can be irreversible damage to genital organ. This time, hydraulic cutter was conduct by fireman (Figure 2). We seperated ring from skin by using spatula.

clinical-case-reports-hydraulic-cutter

Figure 2: Rescue by hydraulic cutter.

Three ring was broken down individually in 10 minutes without any iatrogenic injury (Figure 3). After ring removal, pain improved, and only tiny ringcompression related ulceration wound and scrotal wall and prepuce edema were found. He was discharged uneventful from our ER with oral form antibiotics and pain killer later.

clinical-case-reports-ring-removal

Figure 3: Successful ring removal.

Discussion

It is a challenge to deal with those strangulation in ER setting. Several device had been reported using for rescue external genitalia strangulation [1-2]. However, most of those devices may not be available in hospital. In Taiwan, at most time, we contacted with fireman for device support. However, standard rescue method may not be established yet. It may be hard to develop standard rescue solution for different material and type constricting devices. In those two cases in our hospital, we had used angle grinder and hydraulic cutter respectively. Both cases were saved without specific consequence. However, it may increase unnecessary risk of blood borne disease transmission with angle grinder. Possible cutting or thermal injury may also happen to patient or medical staff by angle grinder.

Previous report supported this viewpoint [3-5]. Kyei et al. reported electric circular grinder removed metallic nut successfully but induced thermal burns leading to urethrocutaneous fistula [3]. On the top of that, a positive correlation was found between the time of incarceration and the length of hospitalization [4]. A report from previous successful stragulation removal by motoroperated emery wheel machine revealed that the mean operation duration was 36 minutes [5]. Hence, hydraulic cutter may be a safer and sooner way in our patient situation.

Conclusion

We reported a nonrare case of male external genitalia strangulation by steel ring. It may be safer method to rescue with hydraulic cutter instead of angle grinder especially in those patient with blood borne disease. However, management may be individualized for difference material and shape of constricting device.

References

Select your language of interest to view the total content in your interested language
Post your comment

Share This Article

Relevant Topics

Article Usage

  • Total views: 8773
  • [From(publication date):
    July-2016 - Nov 18, 2019]
  • Breakdown by view type
  • HTML page views : 8694
  • PDF downloads : 79
Top