Make the best use of Scientific Research and information from our 700+ peer reviewed, Open Access Journals that operates with the help of 50,000+ Editorial Board Members and esteemed reviewers and 1000+ Scientific associations in Medical, Clinical, Pharmaceutical, Engineering, Technology and Management Fields.
Meet Inspiring Speakers and Experts at our 3000+ Global Conferenceseries Events with over 600+ Conferences, 1200+ Symposiums and 1200+ Workshops on
Medical, Pharma, Engineering, Science, Technology and Business

The Relation between Sterilization Validation and Nosocomial Infection

Hideharu Shintani*

Chuo University, School of Science, 1-13-27, Kasuga Bunkyo 112-0003 Tokyo, Japan

Corresponding Author:

Hideharu Shintani
Chuo University, School of Science
1-13-27, Kasuga Bunkyo 112-0003 Tokyo, Japan
Tel: +81425922336
E-mail: [email protected]

Received date: October 29, 2013; Accepted date: October 30, 2013; Published date: November 01, 2013

Citation: Shintani H (2013) The Relation between Sterilization Validation and Nosocomial Infection. Chem Sci J 4:073. doi:10.4172/2150-3494.1000073

Copyright: © 2013 Shintani H. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

Visit for more related articles at Chemical Sciences Journal

Sterilization validation is so often considered to attain SAL (Sterility Assurance Level) of 10-6, but this is not correct. The correct is to attain both simultaneously SAL of 10-6 and material and functional compatibility of the sterilized devices. SAL of 10-6 can be easily attained by using BI (Biological indicator) and D (decimal reduction value). For example it is 12D as an overkill method. On the contrary, it is quite hard to attain material and functional compatibility to the products exposed up to SAL of 10-6. One typical example is the sterilization of endoscope. Endoscope is repeatedly used after sterilization, but the endoscope part to carry out biopsy is deteriorated after a few times use. So, sterilization is not conducted and HClO (pH 4-6) or only water washing is so often conducted in the exact healthcare facilities. By these methods purion, hepatitis virus or H. pylori is infected between human to human during endoscope inspection. Most easy method for sterilization of endoscope is gamma-ray irradiation. It is true that it can attain SAL of 10-6 in ease, but most often material and functional compatibility cannot attain. According to the author’s experience (already reported), for example, artificial dialyzer was sterilized with gamma-ray up to SAL of 10-6, material degraded and toxic and endocrine disrupter of bisphenol A is produced. Resemble phenomenon can be observed when exposed to polyurethane, polyurethane degraded and toxic 4,4`-methylene dianiline (MDA) produced at significant amount.

From the above it can be understood to be quite hard to attain simultaneously both SAL of 10-6 and material functional compatibility. Therefore, ISO documents do not describe definitely to attain material and functional compatibility at sterilization validation and inspector may not ask for material and functional compatibility of the sterilized devices. However, in the exact status SAL of 10-6 and material and functional compatibility must be attained in success simultaneously. Inspectors are not trained to ask for material and functional compatibility of the sterilized devices up to SAL of 10-6, so you need not be necessary as they do not ask for material and functional compatibility. But you must prepare for healthcare facilities because you are inquired how to sterilize to reuse the fragile medical devices. Officially dialyzer is not approved to use multi times and only single use is approved. On the contrary endoscope is approved to use multi uses after sterilization per each time, but right now no appropriate sterilization procedures are available and only water washing or HCLO (pH 4-6) washing is currently used. Both methods are not sterilization procedures, so nosocomial infection can be observed by prion, hepatitis virus or H. pylori. They are not successfully decontaminated (sterilized) and they may cause nosocomial infection. The definite sterilization procedure to attain SAL of 10-6 and material and functional compatibility is keenly required in addition to diminish nosocomial infection by appropriate sterilization procedure. The sterilization is the future problem to the fragile medical devices at healthcare facilities. Right now, gas plasma sterilization is one of desirable sterilization, which the author is studied for endoscope part to conduct biopsy.

Select your language of interest to view the total content in your interested language
Post your comment

Share This Article

Relevant Topics

Recommended Conferences

Article Usage

  • Total views: 11871
  • [From(publication date):
    December-2013 - Oct 18, 2017]
  • Breakdown by view type
  • HTML page views : 8042
  • PDF downloads :3829
 

Post your comment

captcha   Reload  Can't read the image? click here to refresh

Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

Agri, Food, Aqua and Veterinary Science Journals

Dr. Krish

[email protected]

1-702-714-7001 Extn: 9040

Clinical and Biochemistry Journals

Datta A

[email protected]

1-702-714-7001Extn: 9037

Business & Management Journals

Ronald

[email protected]

1-702-714-7001Extn: 9042

Chemical Engineering and Chemistry Journals

Gabriel Shaw

[email protected]

1-702-714-7001 Extn: 9040

Earth & Environmental Sciences

Katie Wilson

[email protected]

1-702-714-7001Extn: 9042

Engineering Journals

James Franklin

[email protected]

1-702-714-7001Extn: 9042

General Science and Health care Journals

Andrea Jason

[email protected]micsonline.com

1-702-714-7001Extn: 9043

Genetics and Molecular Biology Journals

Anna Melissa

[email protected]

1-702-714-7001 Extn: 9006

Immunology & Microbiology Journals

David Gorantl

[email protected]

1-702-714-7001Extn: 9014

Informatics Journals

Stephanie Skinner

[email protected]

1-702-714-7001Extn: 9039

Material Sciences Journals

Rachle Green

[email protected]

1-702-714-7001Extn: 9039

Mathematics and Physics Journals

Jim Willison

[email protected]

1-702-714-7001 Extn: 9042

Medical Journals

Nimmi Anna

[email protected]

1-702-714-7001 Extn: 9038

Neuroscience & Psychology Journals

Nathan T

[email protected]

1-702-714-7001Extn: 9041

Pharmaceutical Sciences Journals

John Behannon

[email protected]

1-702-714-7001Extn: 9007

Social & Political Science Journals

Steve Harry

[email protected]

1-702-714-7001 Extn: 9042

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords