alexa
Reach Us +32 466 902143
Autotransplantation of an Impacted Second Premolar in its Predecessorand#195;and#162;and#194;and#8364;and#194;and#8482;s Socket with the Novel use of Modern Imaging System: A Case Report with 18 Months Follow Up | Abstract
ISSN: 2167-1222

Journal of Trauma & Treatment
Open Access

Our Group organises 3000+ Global Conferenceseries Events every year across USA, Europe & Asia with support from 1000 more scientific Societies and Publishes 700+ Open Access Journals which contains over 50000 eminent personalities, reputed scientists as editorial board members.

Open Access Journals gaining more Readers and Citations
700 Journals and 15,000,000 Readers Each Journal is getting 25,000+ Readers

This Readership is 10 times more when compared to other Subscription Journals (Source: Google Analytics)

Case Report

Autotransplantation of an Impacted Second Premolar in its Predecessor’s Socket with the Novel use of Modern Imaging System: A Case Report with 18 Months Follow Up

Divya S Sharma1*, Shikhar Pratap Singh Chauhan1, Rajesh Kishnan2 and Sanjay Sharma3
1Department of Pediatric and Preventive Dentistry, Modern Dental College & Research Centre, Indore (MP), India
2 Department of Orthodontics, Modern Dental College & Research Centre, Indore (MP), India
3 Department of Prosthodontics, Crown & Bridge and Implantology, Modern Dental College & Research Centre, Indore (MP), India
Corresponding Author : Divya S Sharma
Department of Pediatric and Preventive Dentistry
Modern Dental College & Research Centre, Indore (MP), India
Tel: +919977701098
E-mail: [email protected]
Received November 24, 2011; Accepted December 27, 2011; Published January 10, 2012
Citation: Sharma DS, Singh Chauhan SP, Kishnan R, Sharma S (2011) Autotransplantation of an Impacted Second Premolar in its Predecessor’s Socket with the Novel use of Modern Imaging System: A Case Report with 18 Months Follow Up. J Trauma Treatment 1:103. doi:10.4172/2167-1222.1000103
Copyright: © 2011 Sharma DS, et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

Abstract

The case repost presents a successful autotransplantation of maxillary second premolar, impacted at an unusual site, in its predecessor’s socket. The location of impacted tooth was diagnosed with the help of 3D construction 3D CT scan. 3D construction was further modified to unveil the exact location of impacted tooth making best use of softwares incorporated in modern imaging systems. The good diagnosis decreased the time to be taken in surgical procedure which in turn resulted in successful outcome of autotransplantation.

Recommended Conferences
Share This Page
Top