alexa Capecitabine: AnIn-vitro Comparison between the Branded Xeloda® 500 Mg nd its Intended Copy Capeda 500 Mg
ISSN: 2161-0444

Medicinal Chemistry
Open Access

Like us on:
OMICS International organises 3000+ Global Conferenceseries Events every year across USA, Europe & Asia with support from 1000 more scientific Societies and Publishes 700+ Open Access Journals which contains over 50000 eminent personalities, reputed scientists as editorial board members.

Open Access Journals gaining more Readers and Citations

700 Journals and 15,000,000 Readers Each Journal is getting 25,000+ Readers

This Readership is 10 times more when compared to other Subscription Journals (Source: Google Analytics)

Research Article

Capecitabine: AnIn-vitro Comparison between the Branded Xeloda® 500 Mg nd its Intended Copy Capeda 500 Mg

Mubarak Nasser AlAmeri1*, Simon Abi Aad2, Arthur Tucker1 and Atholl Johnston1

1William Harvey Research Institute, Barts and The London, School of Medicine and Dentistry, Queen Mary University of London EC1M 6BQ, UK

2St. Luke’s-Roosevelt Hospital Centre, Department of Medicine, Manhattan, New York, USA

*Corresponding Author:
Mubarak N. Al Ameri
Clinical Pharmacology, Barts and The London
Charterhouse Square, London, EC1M 6BQ, UK
Tel: +44-20-7882 3413
Fax: +44-20-78823408
E-mail: [email protected]

Received date: May 23, 2012; Accepted date: August 21, 2012; Published date: August 23, 2012

Citation: AlAmeri MN, Aad SA, Tucker A, Johnston A (2012) Capecitabine: An In-vitro Comparison between the Branded Xeloda® 500 Mg and its Intended Copy Capeda 500 Mg. Med chem 2:112-118. doi:10.4172/2161-0444.1000125

Copyright: © 2012 AlAmeri MN, et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

Abstract

Introduction: Dissolution is an example of in-vitro test which can be used to identify formulations that may present potential bioequivalence problems. It is defined as the amount of substance that goes into solution per unit time under standardised conditions of liquid/solid interface, solvent composition and temperature. It is considered one of the most important tools to predict the in-vivo bioavailability and in some cases replacing clinical studies to determine bioequivalence. Aim: To compare the differences in the dissolution behaviour between two anticancer formulations, Xeloda® 500 mg (reference product) and Capeda 500 mg (test product). Methods: Four replicates for each batch of the tested medicines were carried out using a PT-DT70 dissolution tester (Pharma Test) to detect any differences in their dissolution behaviour. Samples at nine time intervals were tested according to the US Pharmacopeia with the rate of dissolution determined by ultra-violet spectrophotometery. Results: All the tested medicines complied with the pharmacopoeial specifications, the EMA and the FDA guidance for industry when achieved 85% dissolution in 60 minutes. However, Capeda 500 mg (test product) showed slower, different and incomplete dissolution rate compared to Xeloda® 500 mg (reference product) at both 60 and 120 minutes. Other visual differences in the weight, size, clarity of solution, presence of un-dissolved residue and particles during the dissolution test were also detected. Conclusion: Results in this study clearly raise a question about the interchangeability between Xeloda® 500 mg and its Intended copy Capeda 500 mg. Awareness of these scientific concerns should be considered when a clinical choice between these two drugs is required. Differences between the innovator and copy medicines with regard to pharmacokinetics, clinical efficacy and safety may exist. Thereby, patients’ monitoring after performing drug substitution of these two medicines is strongly recommended.

Keywords

Share This Page

Additional Info

Loading
Loading Please wait..
 
Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

Agri & Aquaculture Journals

Dr. Krish

[email protected]

1-702-714-7001Extn: 9040

Biochemistry Journals

Datta A

[email protected]

1-702-714-7001Extn: 9037

Business & Management Journals

Ronald

[email protected]

1-702-714-7001Extn: 9042

Chemistry Journals

Gabriel Shaw

[email protected]

1-702-714-7001Extn: 9040

Clinical Journals

Datta A

[email protected]

1-702-714-7001Extn: 9037

Engineering Journals

James Franklin

[email protected]

1-702-714-7001Extn: 9042

Food & Nutrition Journals

Katie Wilson

[email protected]

1-702-714-7001Extn: 9042

General Science

Andrea Jason

[email protected]

1-702-714-7001Extn: 9043

Genetics & Molecular Biology Journals

Anna Melissa

[email protected]

1-702-714-7001Extn: 9006

Immunology & Microbiology Journals

David Gorantl

[email protected]

1-702-714-7001Extn: 9014

Materials Science Journals

Rachle Green

[email protected]

1-702-714-7001Extn: 9039

Nursing & Health Care Journals

Stephanie Skinner

[email protected]

1-702-714-7001Extn: 9039

Medical Journals

Nimmi Anna

[email protected]

1-702-714-7001Extn: 9038

Neuroscience & Psychology Journals

Nathan T

[email protected]

1-702-714-7001Extn: 9041

Pharmaceutical Sciences Journals

Ann Jose

[email protected]

1-702-714-7001Extn: 9007

Social & Political Science Journals

Steve Harry

[email protected]

1-702-714-7001Extn: 9042

 
© 2008- 2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords