alexa Comparative Evaluation of Lightwand (Lighted Stylet) wi
ISSN: 2155-6148

Journal of Anesthesia & Clinical Research
Open Access

Like us on:
OMICS International organises 3000+ Global Conferenceseries Events every year across USA, Europe & Asia with support from 1000 more scientific Societies and Publishes 700+ Open Access Journals which contains over 50000 eminent personalities, reputed scientists as editorial board members.

Open Access Journals gaining more Readers and Citations

700 Journals and 15,000,000 Readers Each Journal is getting 25,000+ Readers

This Readership is 10 times more when compared to other Subscription Journals (Source: Google Analytics)

Research Article

Comparative Evaluation of Lightwand (Lighted Stylet) with Direct Laryngoscopy on Hemodynamic Response- A Prospective Study

Manish Jain*, Subham Garg, Bhawana Rastogi, Vijendrapal Singh, Kumkum Gupta and Vaibhav Tiwari
Department of Anaesthesiology, Subharti Medical College, Uttarpradesh, India
Corresponding Author : Manish Jain
Department of Anaesthesiology
Subharti Medical College, Delhi Bypass Road Meerut
Uttarpradesh 250005, India
Tel: +919837343693
E-mail: [email protected]
Received April 04, 2014; Accepted July 21, 2014; Published July 28, 2014
Citation: Jain M, Garg S, Rastogi B, Singh V, Gupta K, et al. (2014) Comparative Evaluation of Lightwand (Lighted Stylet) with Direct Laryngoscopy on Hemodynamic Response-A Prospective Study. J Anesth Clin Res 5:419. doi: 10.4172/2155-6148.1000419
Copyright: © 2014 Jain M, et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
Related article at
DownloadPubmed DownloadScholar Google
 

Abstract

Background:Laryngoscopy and tracheal intubation are often associated with hypertension, tachycardia, and an increase in plasma catecholamine concentrations. The present study was done to compare the hemodynamic response during tracheal intubation, guided by either Lightwand or Direct laryngoscopy.

Method and patients: Seventy adult consented patients of ASA I or II aged 18-58 years of either sex scheduled for elective surgeries from September 2011 to March 2013 were randomized according to sealed envelopes into two groups of 35 patients each. The patients of Group LWI were intubated with lighted stylet (Lightwand, GE) and patients of Group DLI were intubated using direct laryngoscope (Macintosh). Any patient with history of systemic hypertension and cardiopulmonary disease, hepatic, renal or endocrine disorder, difficult airway or MP Grade III & IV, history of previous difficult tracheal intubation or patient who required more than 30 seconds or more than one attempt for intubation were excluded. The anesthetic induction technique was standardized. The hemodynamic parameters of heart rate, blood pressure and ECG were recorded, at baseline, after induction, after tracheal intubation and then at regular interval of 1 min for 5 min after tracheal intubation. Intubation time was noted by stopwatch.

Results: There was no significant difference in demographic profile, in terms of changes in blood pressure and heart rate during laryngoscopy and after tracheal intubation between groups. Post intubation dysphasia, hoarseness, sore throat were also comparable between the groups.

Conclusion: The effects of Lightwand technique on hemodynamic response to tracheal intubation were similar to those of direct laryngoscopy.

Keywords

Share This Page

Additional Info

Loading
Loading Please wait..
 
Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords