alexa Methyl-Β-Cyclodextrin /CTAB Sensitized Fluorescence Method for the Determination of Levofloxacin | OMICS International | Abstract
ISSN : 2153-2435

Pharmaceutica Analytica Acta
Open Access

Like us on:

OMICS International organises 3000+ Global Conferenceseries Events every year across USA, Europe & Asia with support from 1000 more scientific Societies and Publishes 700+ Open Access Journals which contains over 50000 eminent personalities, reputed scientists as editorial board members.

Open Access Journals gaining more Readers and Citations
700 Journals and 15,000,000 Readers Each Journal is getting 25,000+ Readers

This Readership is 10 times more when compared to other Subscription Journals (Source: Google Analytics)

Research Article

Methyl-Β-Cyclodextrin /CTAB Sensitized Fluorescence Method for the Determination of Levofloxacin

Qiuye Ren and Xiashi Zhu*

College of Chemistry & Chemical Engineering, Yangzhou University, Yangzhou 225002, PR China

*Corresponding Author:
Xiashi Zhu
College of Chemistry & Chemical Engineering
Yangzhou University, Yangzhou 225002, PR China
Tel: +86-514-87975244
E-mail: [email protected], [email protected]

Received Date: May 16, 2015; Accepted Date: May 28, 2015; Published Date: June 04, 2015

Citation: Qiuye Ren, Xiashi Zhu (2015) Methyl-Β-Cyclodextrin /CTAB Sensitized Fluorescence Method for the Determination of Levofloxacin. Pharm Anal Acta 6:376. doi: 10.4172/2153-2435.1000376

Copyright: © 2015 Qiuye Ren, et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

Abstract

In this work, the method of methyl-β-cyclodextrin (methyl-β-CD) and cetyltrimethyl ammonium bromide (CTAB) cooperatively sensitized fluorescence analysis to determine levofloxacin (LVFX) was developed. The results were shown that, in the system of methyl-β-cyclodextrin-CTAB, the fluorescence intensity of LVFX increased a lot than in H2O medium. Under the conditions of λex/em=330/507 nm and pH 4.5, the linear range and the detection limit for LVFX were found to be 0.04 ~ 4.0 μg/mL and 0.316 ng/mL, respectively. The mechanism of sensitized fluorescence method was discussed by the Benesi-Hildebrand method and the fluorescence quantum yield of fluorescence. The proposed method has been applied for the determination of LVFX in eye drops real samples with satisfactory recovery.

Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2018-19
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

Agri & Aquaculture Journals

Dr. Krish

[email protected]

1-702-714-7001Extn: 9040

Biochemistry Journals

Datta A

[email protected]

1-702-714-7001Extn: 9037

Business & Management Journals

Ronald

[email protected]

1-702-714-7001Extn: 9042

Chemistry Journals

Gabriel Shaw

[email protected]

1-702-714-7001Extn: 9040

Clinical Journals

Datta A

[email protected]

1-702-714-7001Extn: 9037

Engineering Journals

James Franklin

[email protected]

1-702-714-7001Extn: 9042

Food & Nutrition Journals

Katie Wilson

[email protected]

1-702-714-7001Extn: 9042

General Science

Andrea Jason

[email protected]

1-702-714-7001Extn: 9043

Genetics & Molecular Biology Journals

Anna Melissa

[email protected]

1-702-714-7001Extn: 9006

Immunology & Microbiology Journals

David Gorantl

[email protected]

1-702-714-7001Extn: 9014

Materials Science Journals

Rachle Green

[email protected]

1-702-714-7001Extn: 9039

Nursing & Health Care Journals

Stephanie Skinner

[email protected]

1-702-714-7001Extn: 9039

Medical Journals

Nimmi Anna

[email protected]

1-702-714-7001Extn: 9038

Neuroscience & Psychology Journals

Nathan T

[email protected]

1-702-714-7001Extn: 9041

Pharmaceutical Sciences Journals

Ann Jose

[email protected]

1-702-714-7001Extn: 9007

Social & Political Science Journals

Steve Harry

[email protected]

1-702-714-7001Extn: 9042

 
© 2008- 2018 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
Leave Your Message 24x7