Dersleri yüzünden oldukça stresli bir ruh haline sikiş hikayeleri bürünüp özel matematik dersinden önce rahatlayabilmek için amatör pornolar kendisini yatak odasına kapatan genç adam telefonundan porno resimleri açtığı porno filmini keyifle seyir ederek yatağını mobil porno okşar ruh dinlendirici olduğunu iddia ettikleri özel sex resim bir masaj salonunda çalışan genç masör hem sağlık hem de huzur sikiş için gelip masaj yaptıracak olan kadını gördüğünde porn nutku tutulur tüm gün boyu seksi lezbiyenleri sikiş dikizleyerek onları en savunmasız anlarında fotoğraflayan azılı erkek lavaboya geçerek fotoğraflara bakıp koca yarağını keyifle okşamaya başlar

GET THE APP

The Impact of Traffic Related Air Pollution at Various Sites in Noida | OMICS International| Abstract
ISSN: 2573-458X

Environment Pollution and Climate Change
Open Access

Our Group organises 3000+ Global Conferenceseries Events every year across USA, Europe & Asia with support from 1000 more scientific Societies and Publishes 700+ Open Access Journals which contains over 50000 eminent personalities, reputed scientists as editorial board members.

Open Access Journals gaining more Readers and Citations
700 Journals and 15,000,000 Readers Each Journal is getting 25,000+ Readers

This Readership is 10 times more when compared to other Subscription Journals (Source: Google Analytics)
  • Research Article   
  • Environ Pollut Climate Change 2017, Vol 1(4): 4
  • DOI: 10.4172/2573-458X.1000136

The Impact of Traffic Related Air Pollution at Various Sites in Noida

Jyoti Barnawal*
Amity Institute of Biotechnology, Amity University, Noida, India
*Corresponding Author : Jyoti Barnawal, Amity Institute of Biotechnology, Amity University, Noida, India, Tel: 8800781771, Email: jyotib92@rediffmail.com

Received Date: Aug 01, 2017 / Accepted Date: Aug 11, 2017 / Published Date: Aug 19, 2017

Abstract

Aim: Aim of this study is to access the concentration of air pollutants like particulate matter, black carbon and carbon monoxide at selected roadside locations in Noida and correlate it with base line standard and; to study the adverse health effects of Noida commuters due to ambient air pollution by a survey conducted through questionnaire.

Materials and methods: Methodology being adopted for the study has been discussed under following. 1) Study sites (selection of sites based on traffic): Sites were selected to assess pollutants concentration. The selected sites were places of maximum population, heavy traffic, and commercial areas with industries - a) institutional site, Amity University Noida sector 126; b) arterial road site, Noida sector 18; c) Noida- Greater Noida Expressway; d) residential site, Arun Vihar Noida sector 37. 2) Sampling/monitoring of pollutants such as black carbon, particulate matter and carbon monoxide with the instruments: Micro Aethalometer; CO personal monitor (lengan) and; Dust monitor (grim). 3) Questionnaire survey and traffic sampling and 4) Analysis and interpretation of data.

Results: The average concentration of black carbon were found to be 25107.82 (ng/m3), 16829.65 (ng/m3), 23112.56 (ng/m3) at Noida Sector 126, Noida Sector 18, Noida-Greater Noida Expressway, respectively. The concentration were compared and it was found that average concentration of black carbon level obtained at Noida Sector 126 was maximum and mean BC concentration varies from 68707.82-8760.76 (ng/3). This is due to traffic, vehicles and diesel combustion. The average concentration of PM10 were found to be 1737.16 ug/3, 632.69 (ng/3), 466.29(ng/3) at Noida sector 126, Noida Sector 18, Noida-Greater Noida Expressway respectively. The concentration were compared and it was found that average concentration of PM10 level obtained at Noida sector 126 was maximum and mean PM10 concentration varies from 2866.62-794.10 ug/3. This is due to high traffic on roads. Mean value of PM2.5 was maximum at Noida sector 126 and variation of PM2.5 values was highest on Noida sector 126 which suggest that contribution from different sources was varying to a great extent. The standard deviation value suggests that PM2.5 source emission rate at Noida sector 126 was varying greater than the emission rate at all the selected sites. The large variation was likely due to the differences in air mass, emission characteristics and meteorology. Results were compared with the values obtained by Central Pollution Control Board. Mean PM10 concentration at Noida sector 126 was 1737.16 ug/m 3 which is more than ten times higher than the standard value. Similarly mean PM2.5 concentration is ten times higher than the standard value. In Noida, institutional site is highly affected due to construction work and road traffic. Relevant information was gathered from questionnaire survey. It was observed that 80% of the people were suffering from eye or skin irritation at Noida sector 126 where the Black carbon and PM10, PM2.5, PM1 conc. were found maximum in comparision to all other sites.

Keywords: Pollutants; Traffic; Industrialization

Citation: Barnawal J (2017) The Impact of Traffic Related Air Pollution at Various Sites in Noida. Environ Pollut Climate Change 1:136. Doi: 10.4172/2573-458X.1000136

Copyright: © 2017 Barnawal J. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.