alexa The Accuracy and Reliability of Non-Invasive Haemoglobin Measurements in the Emergency Room: a Small Prospective Observational Quality Control Study from a Swiss University Hospital ED
ISSN: 2165-7548

Emergency Medicine: Open Access
Open Access

OMICS International organises 3000+ Global Conferenceseries Events every year across USA, Europe & Asia with support from 1000 more scientific Societies and Publishes 700+ Open Access Journals which contains over 50000 eminent personalities, reputed scientists as editorial board members.

Open Access Journals gaining more Readers and Citations

700 Journals and 15,000,000 Readers Each Journal is getting 25,000+ Readers

This Readership is 10 times more when compared to other Subscription Journals (Source: Google Analytics)

Research Article

The Accuracy and Reliability of Non-Invasive Haemoglobin Measurements in the Emergency Room: a Small Prospective Observational Quality Control Study from a Swiss University Hospital ED

Mairi Ziaka1*, Susanne Nuesch2, Christian Tasso Braun2, Marco Jankovic1,3, Meret E. Ricklin DVM2 and Aristomenis Exadaktylos2

1Intermediate Care Unit, University Hospital Basel, Basel, Switzerland

2Department of Emergency Medicine, Inselspital, University Hospital Bern, Bern, Switzerland

3ARTORG Center for Biomedical Engineering Research, University of Bern, Murtenstrasse 590, 3010 Bern, Switzerland

*Corresponding Author:
Mairi Ziaka
Intermediate Care Unit
University Hospital Basel, Spitalstr. 21, 4031 Basel, Switzerland
Tel: +41 (0)61 556 59 42
E-mail: [email protected]

Received Date: May 17, 2016; Accepted Date: May 24, 2016; Published Date: May 31, 2016

Citation: Ziaka M, Nuesch S, Braun CT, Jankovic M, Ricklin DVMME, et al. (2016) The Accuracy and Reliability of Non-Invasive Haemoglobin Measurements in the Emergency Room: a Small Prospective Observational Quality Control Study from a Swiss University Hospital ED. Emerg Med (Los Angel) 6: 324. doi:10.4172/2165-7548.1000324

Copyright: © 2016 Ziaka M, et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

 

Abstract

Background: The accuracy and reliability of non-invasive oximetry for haemoglobin measurements were reported in operating rooms and intensive care units, though few studies evaluated this technology in emergency departments. The purpose of this study was to evaluate the accuracy and reliability of non-invasive SpHb readings from a portable device, in emergency department patients, compared to synchronous LabHb measurements. The authors sought to minimise external variables that could influence device performance, including learning curves and patient conditions, thus performed measurements by one trained user on stable adults only.
Methods: The authors enrolled 24 consecutive adults admitted to the emergency department suspected or manifest active bleeding, and excluded cases of incarceration, pregnancy and burns. Haemoglobin concentrations were synchronously measured by phlebotomy laboratory analysis (LabHb) and using non-invasive readings (SpHb) from a portable Pronto-7 Pulse CO-Oximeter.
Results: The non-invasive SpHb concentrations were recorded in 24 patients (100%), but the device it aborted during one or more measurement in 8 patients (33.3%) due to tremor and shivering. Paired comparison of SpHb and LabHb revealed a mean absolute error of 1.2 ± 1.3 g/dL (median 0.7, range 0.1 to 0.5), which equates to relative error of 9% ± 14% (median 5%, range 1% to 59%).
Conclusions: Non-invasive SpHb measurements deviate from the ‘gold standard’ LabHb by an average of 1.2 g/dL (10%), but that outliers could be up to 5.2 g/dL (59%), which could lead to conflicting clinical decisions. Furthermore, the device functioned correctly in only 16 of 24 patients (66.6%), which should be reviewed in the light of difficult emergency department settings.

Keywords

Share This Page

Additional Info

Loading
Loading Please wait..
 
Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

Agri, Food, Aqua and Veterinary Science Journals

Dr. Krish

[email protected]

1-702-714-7001 Extn: 9040

Clinical and Biochemistry Journals

Datta A

[email protected]

1-702-714-7001Extn: 9037

Business & Management Journals

Ronald

[email protected]

1-702-714-7001Extn: 9042

Chemical Engineering and Chemistry Journals

Gabriel Shaw

[email protected]

1-702-714-7001 Extn: 9040

Earth & Environmental Sciences

Katie Wilson

[email protected]

1-702-714-7001Extn: 9042

Engineering Journals

James Franklin

[email protected]

1-702-714-7001Extn: 9042

General Science and Health care Journals

Andrea Jason

[email protected]

1-702-714-7001Extn: 9043

Genetics and Molecular Biology Journals

Anna Melissa

[email protected]

1-702-714-7001 Extn: 9006

Immunology & Microbiology Journals

David Gorantl

[email protected]

1-702-714-7001Extn: 9014

Informatics Journals

Stephanie Skinner

[email protected]

1-702-714-7001Extn: 9039

Material Sciences Journals

Rachle Green

[email protected]

1-702-714-7001Extn: 9039

Mathematics and Physics Journals

Jim Willison

[email protected]

1-702-714-7001 Extn: 9042

Medical Journals

Nimmi Anna

[email protected]

1-702-714-7001 Extn: 9038

Neuroscience & Psychology Journals

Nathan T

[email protected]

1-702-714-7001Extn: 9041

Pharmaceutical Sciences Journals

John Behannon

[email protected]

1-702-714-7001Extn: 9007

Social & Political Science Journals

Steve Harry

[email protected]

1-702-714-7001 Extn: 9042

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords