alexa Corrosion Assessment And Failure Analysis Of Explanted Hip Prostheses
ISSN: 2169-0022

Journal of Material Sciences & Engineering
Open Access

OMICS International organises 3000+ Global Conferenceseries Events every year across USA, Europe & Asia with support from 1000 more scientific Societies and Publishes 700+ Open Access Journals which contains over 50000 eminent personalities, reputed scientists as editorial board members.

Open Access Journals gaining more Readers and Citations

700 Journals and 15,000,000 Readers Each Journal is getting 25,000+ Readers

This Readership is 10 times more when compared to other Subscription Journals (Source: Google Analytics)

Share This Page

Additional Info

Loading
Loading Please wait..
 

3rd International Conference and Exhibition on Materials Science & Engineering
October 06-08, 2014 Hilton San Antonio Airport, USA

N Munroe, K Jones and J Gonzalez
ScientificTracks Abstracts: J Material Sci Eng
DOI: 10.4172/2169-0022.S1.014
Abstract
Recent increase in the recall of prosthetic devices used for total hip replacement, have prompted researchers to investigate tribological (metal on metal) interactions of implants. The increased failure rates are sometimes associated with the deleterious effect of metallic debris on surrounding tissues, which have led to tumors. The bearing surfaces of hip prostheses are not the only source of metallic debris. Tribocorrosion at the taper surfaces of modular hip prostheses is a critical issue that becomes progressively worse with time and has in some cases been identified as the cause of early failure. The recent increase in the use of bimodular systems, alongside a trend towards younger patients with more demanding needs, creates an imperative to research the complex interactions at these interfaces. The inadequacy of hip simulator based testing, as evidenced by recent MoM recalls, makes the use of large sample sets of explanted hip prostheses necessary for any comprehensive investigation. In this investigation, explanted arthroplasty samples are examined using macroscopic light and scanning electron microscopy and energy dispersive X-ray analysis, as well as transmission electron microscopy. Evidence of in vivo frettingassisted crevice corrosion of the mating surfaces of modular head-neck components and galvanic corrosion are assessed via potentiodynamic polarization tests in accordance with ASTM G5 standard. Attempts are made to determine whether the artifacts on the surface of samples are influenced by factors such as manufacturing method, type of material, design and length of implantation.
image PDF   |   image HTML
 

Relevant Topics

Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords