alexa
Reach Us +3225889658
Determination Of Polycyclic Aromatic Hydrocarbons In Sediments Of Rain Drainage Channels In Urban Zone (Pelotas - RS, Brazil) | 28878
ISSN: 2157-7064

Journal of Chromatography & Separation Techniques
Open Access

Like us on:

Our Group organises 3000+ Global Conferenceseries Events every year across USA, Europe & Asia with support from 1000 more scientific Societies and Publishes 700+ Open Access Journals which contains over 50000 eminent personalities, reputed scientists as editorial board members.

Open Access Journals gaining more Readers and Citations
700 Journals and 15,000,000 Readers Each Journal is getting 25,000+ Readers

This Readership is 10 times more when compared to other Subscription Journals (Source: Google Analytics)

Determination of polycyclic aromatic hydrocarbons in sediments of rain drainage channels in urban zone (Pelotas - RS, Brazil)

International Summit on Current Trends in Mass Spectrometry

Pedro J Sanches Filho, Gissele O Montenegro, Glauco R Betemps and Bernardo Vaz

ScientificTracks Abstracts: J Chromatogr Sep Tech

DOI: 10.4172/2157-7064.S1.007

Abstract
The presence of polycyclic aromatic hydrocarbons (PAHs) and mixture composition in sediments can also be as an indication of sources of pollution. The objective of this study is to evaluate the contamination sources by hydrocarbons derived from urban areas capitated by storm water drainage systems, and determine the levels of PAHs in the studies channels. The extraction of analytes from sample was made in Soxhlet/ultrasonic bath, and with solvents mixture of hexane and acetone.The fractionation of extracts was performed using a column of Na2SO4, silica and alumina. For the chromatographic analysis, the fractions were injected in the GG-MS in split less mode. The hydrocarbons were quantified using a GC-MS (Shimadzu QP 2010 ultra), with a RTX 5MS column. Injector and interface were maintained at 280ºC and ions source at 200ºC, respectively.The electron-impact (EI) ionization energy was 70 eV, and the carrier gas was Helium (99.999%) at a constant flow rate of 1.0 mL min?1in SIM mode (m/z were, 128, 142, 152, 154, 166, 178, 202, 228, 252, 276, 278). The detection in SIM mode led to a reduction in detection limits and permitted electronic cleanup of the extracts analyzed. We observed that most PAHs detected and quantified showed 4 to 6 rings. The sum of HPAS indicates a moderately impacted environment, with a predominance of pyrolytic sources. This calls attention to the impact of runoff from urban areas under storm drainage channels, leading to these pollutants area of great environmental importance.
Biography
Pedro J Sanches Filho graduated in degree in Chemistry and graduated in Pharmacy (1988), Master?s degree in Chemistry (1997). He obtained the PhD in Analytical chemistry from the Federal University of Rio Grande do Sul (2002) and Post doctoral fellowship by Universidade Nova de Lisboa (2007). He is currently Professor and Researcher at the Instituto Federal de Educação Ciência e Tecnologia Sul-rio-grandense Campus Pelotas -Brazil, leader of the research group on environmental contaminants. He has experience in Analytical Chemistry, with emphasis on Trace Analysis and Environmental Chemistry.
Top