alexa Development And Validation Of A Voltammetric Method For The Determination Of Antimony In Aqueous Medium
ISSN: 2150-3494

Chemical Sciences Journal
Open Access

OMICS International organises 3000+ Global Conferenceseries Events every year across USA, Europe & Asia with support from 1000 more scientific Societies and Publishes 700+ Open Access Journals which contains over 50000 eminent personalities, reputed scientists as editorial board members.

Open Access Journals gaining more Readers and Citations

700 Journals and 15,000,000 Readers Each Journal is getting 25,000+ Readers

This Readership is 10 times more when compared to other Subscription Journals (Source: Google Analytics)

Share This Page

Additional Info

Loading
Loading Please wait..
 

4th European Chemistry Congress
May 11-13, 2017 Barcelona, Spain

Hugo Romero B, Thalia Vera, Kathy Gadvay, Kerly Davila, Fredis Pesantez and Cristhian Vega
Technical University of Machala, Ecuador
ScientificTracks Abstracts: Chem Sci J
DOI: 10.4172/2150-3494-C1-008
Abstract
The objective of this research was to develop and validate a voltammetric method for the determination of antimony in aqueous medium. First, solutions of 5, 10, 15 and 20 mg L-1 of Sb were prepared, using 0.5M phosphoric acid as supporting electrolyte. Additionally, nitrogen was bubbled at 99% purity to remove oxygen from solutions. To measure the concentration of antimony the anodic stripping voltammetry technique was applied, by using a potentiostat multi-channel PARSTAT mark with Versa Princeton Applied Research Studio software. To carry out the registration of voltammograms, a three-electrode system was used, which consisted of glassy carbon as working electrode, Ag / AgCl as reference electrode and a platinum electrode as a counter electrode. In a first stage of the process, a chronoamperometry to E = -1.2 V was applied for a time pre-concentration of 50 s, to achieve this electrodeposition of metallic antimony (Sb0) on the surface of the glassy carbon electrode. Next, a linear sweep voltammetry with potentials between -1.2 V and Ei = Ef = 0.5 V was applied at a rate of ν = 20 mV s-1. To validate the method for quantification of antimony determined linearity, precision, accuracy, detection limit and quantitation limit. The linearity of the method was demonstrated from the proportionality coefficient of 0.9961. The coefficient of variation (CV) had a value of 14.2%, indicating that the accuracy of the method is acceptable. Meanwhile the accuracy is within the criteria for consideration of the method, because a 114% recovery was determined. Additionally it was found that the detection limit and quantitation limit values correspond to 1.45 mg 4.42 mg L- 1 and L 1 respectively.
Biography

Hugo Romero Bonilla has completed the Master's Program in chemistry at the Pontificia Catholic University of Valparaiso, Chile. Currently (2016) he completed the PhD program in environmental science in San Marcos University, Perú. He works as a researcher and professor at the Faculty of Chemistry at the Technical University of Machala, Ecuador where he has served as Director of Chemical Research Center and Director of the Center for Technology Development. Your research lines are Biotechnology and Applied Electrochemistry. He has published some scientific articles papers in reputed journals such as New Biotechnology, Progress in Organic Coutings, Talanta, Advances in Chemistry and Analytical Chemestry Research.

Email: hromero@utmachala.edu.ec

image PDF   |   image HTML
 

Relevant Topics

Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

Agri, Food, Aqua and Veterinary Science Journals

Dr. Krish

agrifoodaquavet@omicsonline.com

1-702-714-7001 Extn: 9040

Clinical and Biochemistry Journals

Datta A

clinical_biochem@omicsonline.com

1-702-714-7001Extn: 9037

Business & Management Journals

Ronald

business@omicsonline.com

1-702-714-7001Extn: 9042

Chemical Engineering and Chemistry Journals

Gabriel Shaw

chemicaleng_chemistry@omicsonline.com

1-702-714-7001 Extn: 9040

Earth & Environmental Sciences

Katie Wilson

environmentalsci@omicsonline.com

1-702-714-7001Extn: 9042

Engineering Journals

James Franklin

engineering@omicsonline.com

1-702-714-7001Extn: 9042

General Science and Health care Journals

Andrea Jason

generalsci_healthcare@omicsonline.com

1-702-714-7001Extn: 9043

Genetics and Molecular Biology Journals

Anna Melissa

genetics_molbio@omicsonline.com

1-702-714-7001 Extn: 9006

Immunology & Microbiology Journals

David Gorantl

immuno_microbio@omicsonline.com

1-702-714-7001Extn: 9014

Informatics Journals

Stephanie Skinner

omics@omicsonline.com

1-702-714-7001Extn: 9039

Material Sciences Journals

Rachle Green

materialsci@omicsonline.com

1-702-714-7001Extn: 9039

Mathematics and Physics Journals

Jim Willison

mathematics_physics@omicsonline.com

1-702-714-7001 Extn: 9042

Medical Journals

Nimmi Anna

medical@omicsonline.com

1-702-714-7001 Extn: 9038

Neuroscience & Psychology Journals

Nathan T

neuro_psychology@omicsonline.com

1-702-714-7001Extn: 9041

Pharmaceutical Sciences Journals

John Behannon

pharma@omicsonline.com

1-702-714-7001Extn: 9007

Social & Political Science Journals

Steve Harry

social_politicalsci@omicsonline.com

1-702-714-7001 Extn: 9042

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords