GET THE APP

Development and validation of a voltammetric method for the determination of antimony in aqueous medium
..

Chemical Sciences Journal

ISSN: 2150-3494

Open Access

Development and validation of a voltammetric method for the determination of antimony in aqueous medium


4th European Chemistry Congress

May 11-13, 2017 Barcelona, Spain

Hugo Romero B, Thalia Vera, Kathy Gadvay, Kerly Davila, Fredis Pesantez and Cristhian Vega

Technical University of Machala, Ecuador

Scientific Tracks Abstracts: Chem Sci J

Abstract :

The objective of this research was to develop and validate a voltammetric method for the determination of antimony in aqueous medium. First, solutions of 5, 10, 15 and 20 mg L-1 of Sb were prepared, using 0.5M phosphoric acid as supporting electrolyte. Additionally, nitrogen was bubbled at 99% purity to remove oxygen from solutions. To measure the concentration of antimony the anodic stripping voltammetry technique was applied, by using a potentiostat multi-channel PARSTAT mark with Versa Princeton Applied Research Studio software. To carry out the registration of voltammograms, a three-electrode system was used, which consisted of glassy carbon as working electrode, Ag / AgCl as reference electrode and a platinum electrode as a counter electrode. In a first stage of the process, a chronoamperometry to E = -1.2 V was applied for a time pre-concentration of 50 s, to achieve this electrodeposition of metallic antimony (Sb0) on the surface of the glassy carbon electrode. Next, a linear sweep voltammetry with potentials between -1.2 V and Ei = Ef = 0.5 V was applied at a rate of ���½ = 20 mV s-1. To validate the method for quantification of antimony determined linearity, precision, accuracy, detection limit and quantitation limit. The linearity of the method was demonstrated from the proportionality coefficient of 0.9961. The coefficient of variation (CV) had a value of 14.2%, indicating that the accuracy of the method is acceptable. Meanwhile the accuracy is within the criteria for consideration of the method, because a 114% recovery was determined. Additionally it was found that the detection limit and quantitation limit values correspond to 1.45 mg 4.42 mg L- 1 and L 1 respectively.

Biography :

Hugo Romero Bonilla  has completed the Master's Program in chemistry at the Pontificia Catholic University of Valparaiso, Chile. Currently (2016) he completed the PhD program in environmental science in San Marcos University, Perú. He works as a researcher and professor at the Faculty of Chemistry at the Technical University of Machala, Ecuador where he has served as Director of Chemical Research Center and Director of the Center for Technology Development. Your research lines are Biotechnology and Applied Electrochemistry.   He has published  some scientific articles papers in reputed journals such as New Biotechnology, Progress in Organic Coutings, Talanta, Advances in Chemistry and Analytical Chemestry Research.
Email:hromero@utmachala.edu.ec
 

Google Scholar citation report
Citations: 912

Chemical Sciences Journal received 912 citations as per Google Scholar report

Chemical Sciences Journal peer review process verified at publons

Indexed In

 
arrow_upward arrow_upward