alexa Magnetic Solid Phase Microextraction For Determination Of Caffeine Coupled With Poly (Alizarin Red) Modified Screen-printed Carbon Electrode Detection
ISSN: 2161-0398

Journal of Physical Chemistry & Biophysics
Open Access

Like us on:
OMICS International organises 3000+ Global Conferenceseries Events every year across USA, Europe & Asia with support from 1000 more scientific Societies and Publishes 700+ Open Access Journals which contains over 50000 eminent personalities, reputed scientists as editorial board members.

Open Access Journals gaining more Readers and Citations

700 Journals and 15,000,000 Readers Each Journal is getting 25,000+ Readers

This Readership is 10 times more when compared to other Subscription Journals (Source: Google Analytics)

Share This Page

Additional Info

Loading
Loading Please wait..

3rd International Conference on Electrochemistry
July 10-11, 2017 Berlin, Germany

Hayati Filik and Asiye A Avan
Istanbul University, Turkey
Posters & Accepted Abstracts: J Phys Chem Biophys
DOI: 10.4172/2161-0398-C1-020
Abstract
Caffeine (CAF) is a natural stimulant most commonly found in some plant species. Caffeine is present naturally or added to widely consumed foods. It is also found in cola-type soft drinks and energy drinks that mainly contain artificial CAF. However, too much CAF consumption can cause the muscles effects for a move erratically. The quantity of the CAF in the matrix, whether it is the major compound or if it is found in trace quantity, is the very important topic. We introduce magnetic solid phase microextraction coupled with electrochemical detection. Screen-printed carbon electrode-based electrochemical detection has been successfully combined with m-SPME for the first time. SPCEs modified with conducting polymer (poly-alizarin red S) are employed as electrochemical transducers in the analyte detection stage. The Fe3O4 coated MWCNTs nanocomposite was prepared as a sorbent to quickly extract analyte from aqueous samples. m-SPME) is a well-known process for the enrichment of hydrophobic species from water sample without the use of toxic organic solvents. Miniaturization of both analytical instrumentation and analytical methodologies has become very popular, and many efforts have focused on carrying out chemical analysis at a reduced scale. In the study, the commercially available disposable screen-printed carbon electrodes modified with poly Alizarin Red S are employed as electrochemical sensors in the detection stage. However, the suitability of m-SPME for electroanalytical methods such as SWV has not been declared. With our optimized conditions in hand, the system response was linearly proportional to the concentration of caffeine in the range of 0.5–20 μM with a correlation coefficient of about 0.9987. The LOD of the sensing system at a signal to noise ratio of 3 was 0.05 μM. At the end of the study, the suitability of this new procedure for the analysis of energy drink and soft drink samples was demonstrated.
Biography

Hayati Filik obtained his PhD degree in Analytical Chemistry from Istanbul University, Istanbul, Turkey in 1993. He currently works as a Professor of Chemistry at Istanbul University. His fields of interest are analytical chemistry, environmental chemistry and electroanalytical chemistry.

Email: [email protected]

image PDF   |   image HTML
 
Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords