alexa MICS With Toric Intraocular Lenses In Keratoconus: Outcomes And Predictability Analysis Of Postoperative Refraction
ISSN: 2155-9570

Journal of Clinical & Experimental Ophthalmology
Open Access

Like us on:
OMICS International organises 3000+ Global Conferenceseries Events every year across USA, Europe & Asia with support from 1000 more scientific Societies and Publishes 700+ Open Access Journals which contains over 50000 eminent personalities, reputed scientists as editorial board members.

Open Access Journals gaining more Readers and Citations

700 Journals and 15,000,000 Readers Each Journal is getting 25,000+ Readers

This Readership is 10 times more when compared to other Subscription Journals (Source: Google Analytics)

10th International Conference on Clinical & Experimental Ophthalmology
November 21-23, 2016 Dubai, UAE

Felipe A Soria, Jorge L Alio, Pablo Pena-Garcia, Fidan Abdulla Guliyeva, Ghassam Zein and Sabat K Abu-Mustafa
Vissum Corporación, Spain
Corporacion Alicante,Spain
Universidad Miguel Hernández, Spain
Ahmadi Hospital Kuwait, Kuwait
ScientificTracks Abstracts: J Clin Exp Ophthalmol
DOI: 10.4172/2155-9570.C1.048
Abstract
Aim: To investigate the visual and refractive outcomes, safety, efficacy and stability of cataract surgery in eyes with stable keratoconus. Methods: 17 eyes (10 patients) diagnosed as stable keratoconus, aged from 34 to 73 years (56.63±12.47), underwent micro-incision cataract surgery (MICS) followed by implantation of toric intraocular lens (IOL). Seven of them were operated bilaterally and three unilaterally. A complete ophthalmological examinationwas performed preoperatively and postoperatively. The main outcome measures were: uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), keratometry and manifest refraction. Results: Sphere changed from −1.77±6.57D (−11.00 to 7.00) preoperatively to 0.08±0.79D (−1.25 to 1.75) postoperatively (p=0.211), and cylinder changed from −2.95±1.71D (−7.00 to −0.75) to −1.40±1.13D (−3.25 to 0.00) ( p=0.016). UDVA (logMAR) changed from 1.33±0.95 (0.40 to 2.77) to 0.32±0.38 (0.00 to 1.30) (p=0.008) and CDVA (logMAR) changed from 0.32±0.45 (0.01 to 1.77) to 0.20±0.36 (−0.03 to 1.30) (p=0.013). Efficacy and safety indexes were 1.38±0.58 and 1.17±0.66, respectively. Refraction and corneal topography were stable during the follow-up (9.10±5.54 months, 3–15). Conclusions: MICS surgery using corneal topography data and standard formulas for the calculation of the IOL power is a safe and effective procedure regarding keratometric stability, visual and refractive results.
Biography

Felipe A Soria studied Medicine in the Adventist University in Argentina and did Specialty in Ophthalmology in the Vision Institute of Montemorelos University in Mexico. He made the Subspecialties of Cornea, Refractive and Cataract Surgery in Vissum Corporation with Dr. Jorge Alio for a period of two years. He has written more than 30 scientific articles and book chapters, being Editor of the book Femtosecond Laser Assisted Keratoplasty. He has participated with 40 communications in different international congress across the world. He owns the patent: Use of Mesothelial cells in Tissue Bioengineering and Artificial Tissues.

Email: [email protected]

image PDF   |   image HTML
 
Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

Agri & Aquaculture Journals

Dr. Krish

[email protected]

1-702-714-7001Extn: 9040

Biochemistry Journals

Datta A

[email protected]

1-702-714-7001Extn: 9037

Business & Management Journals

Ronald

[email protected]

1-702-714-7001Extn: 9042

Chemistry Journals

Gabriel Shaw

[email protected]

1-702-714-7001Extn: 9040

Clinical Journals

Datta A

[email protected]

1-702-714-7001Extn: 9037

Engineering Journals

James Franklin

[email protected]

1-702-714-7001Extn: 9042

Food & Nutrition Journals

Katie Wilson

[email protected]

1-702-714-7001Extn: 9042

General Science

Andrea Jason

[email protected]

1-702-714-7001Extn: 9043

Genetics & Molecular Biology Journals

Anna Melissa

[email protected]

1-702-714-7001Extn: 9006

Immunology & Microbiology Journals

David Gorantl

[email protected]

1-702-714-7001Extn: 9014

Materials Science Journals

Rachle Green

[email protected]

1-702-714-7001Extn: 9039

Nursing & Health Care Journals

Stephanie Skinner

[email protected]

1-702-714-7001Extn: 9039

Medical Journals

Nimmi Anna

[email protected]

1-702-714-7001Extn: 9038

Neuroscience & Psychology Journals

Nathan T

[email protected]

1-702-714-7001Extn: 9041

Pharmaceutical Sciences Journals

Ann Jose

[email protected]

1-702-714-7001Extn: 9007

Social & Political Science Journals

Steve Harry

[email protected]

1-702-714-7001Extn: 9042

 
© 2008- 2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version