alexa New Concept And Theory Of Myopia Development
ISSN: 2155-9570

Journal of Clinical & Experimental Ophthalmology
Open Access

Like us on:
OMICS International organises 3000+ Global Conferenceseries Events every year across USA, Europe & Asia with support from 1000 more scientific Societies and Publishes 700+ Open Access Journals which contains over 50000 eminent personalities, reputed scientists as editorial board members.

Open Access Journals gaining more Readers and Citations

700 Journals and 15,000,000 Readers Each Journal is getting 25,000+ Readers

This Readership is 10 times more when compared to other Subscription Journals (Source: Google Analytics)

Share This Page

Additional Info

Loading
Loading Please wait..
 

10th International conference on Ophthalmology and Optometry
August 10-11, 2017 Beijing, China

Jui-Teng Lin
New Vision Inc., Taiwan
ScientificTracks Abstracts: J Clin Exp Ophthalmol
DOI: 10.4172/2155-9570-C1-063
Abstract
We will present new concept using an effective axial length and ocular components ratios (L/R1, L/R1) to define the refractive states. Wavefront technology for customized laser in situ keratomileusis (LASIK) is gaining popularity. The standard LASIK procedure that requires only preoperative measurements of the cornea, particularly its front surface curvature and patient refractive error is not sufficient for customized procedures. The whole eye system consists of at least seven optical components: The front and back surface; radius of curvature of the cornea (rl, r2) and of the lens (Rl, R2); cornea and lens thickness (tl, t); anterior chamber depth (S) and globe axial length (L). Most published works about measuring optical components, however, are limited to the analysis of mean values. Measurements by Hosny and colleagues were also limited to the refractive states of L/rl and L/S, but no data were shown for lens curvature or thickness. Given the ratio of r2/rl (about 0.85) and R2/R1 (about 0.7), we able to reduce the seven ocular components to only two refractive states, Cl and C2, given by C1+0.51C2=4.33 - mD/1336, with m=0.003L. For a wide range of values of r2/rl=0.8-0.9, R2/R1=0.6-0.8, rl=6.5-8.5 mm, Rl=9.5-13 mm and L=23 mm, we calculated Cl=2.9-3.4, C2=1.8-2.4, ml=0.067-0.071 and m2=0.134-0.138. Using the referenced parameter set of (f1, f2, So, T, L*)=(31, 60, 3.3, 4.0, 24 mm), an ocular system deviating from this referenced-set, its emmetropic state is governed by an effective axial length L*=22.5+0.36(43.1-D1)+0.3(22.3-D2)+0.5(So-3.3)+0.35(T-4.0), where D1 and D2 are the corneal and lens power. Therefore, myopia is developed as a result of mismatching of above parameters, such that L*>L0 (22.5 mm).
Biography

Jui-Teng Lin has completed his PhD in Physics from University of Rochester, USA in 1981. He is currently the Chairman and CEO of New Vision Inc., Taiwan and Visiting Professor at HE Medical University, China. He has served as a Visiting Professor at National Chao-Tung University and an Associate Professor at the University of Central Florida. He holds over 45 patents and is the Inventor (US patents, 1992, 2000) of flying spot LASIK procedure. He has published over 55 book chapters and over 150 peer review journal papers including 75 SCI-impacted papers.

Email: [email protected]

image PDF   |   image HTML
 
Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

Agri, Food, Aqua and Veterinary Science Journals

Dr. Krish

[email protected]

1-702-714-7001 Extn: 9040

Clinical and Biochemistry Journals

Datta A

[email protected]

1-702-714-7001Extn: 9037

Business & Management Journals

Ronald

[email protected]

1-702-714-7001Extn: 9042

Chemical Engineering and Chemistry Journals

Gabriel Shaw

[email protected]

1-702-714-7001 Extn: 9040

Earth & Environmental Sciences

Katie Wilson

[email protected]

1-702-714-7001Extn: 9042

Engineering Journals

James Franklin

[email protected]

1-702-714-7001Extn: 9042

General Science and Health care Journals

Andrea Jason

[email protected]

1-702-714-7001Extn: 9043

Genetics and Molecular Biology Journals

Anna Melissa

[email protected]

1-702-714-7001 Extn: 9006

Immunology & Microbiology Journals

David Gorantl

[email protected]

1-702-714-7001Extn: 9014

Informatics Journals

Stephanie Skinner

[email protected]

1-702-714-7001Extn: 9039

Material Sciences Journals

Rachle Green

[email protected]

1-702-714-7001Extn: 9039

Mathematics and Physics Journals

Jim Willison

[email protected]

1-702-714-7001 Extn: 9042

Medical Journals

Nimmi Anna

[email protected]

1-702-714-7001 Extn: 9038

Neuroscience & Psychology Journals

Nathan T

[email protected]

1-702-714-7001Extn: 9041

Pharmaceutical Sciences Journals

John Behannon

[email protected]

1-702-714-7001Extn: 9007

Social & Political Science Journals

Steve Harry

[email protected]

1-702-714-7001 Extn: 9042

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords