Zenati Latifa, Boukais Hamid and Boukemouche Abdelkader
University of Blida, Algéria
Posters & Accepted Abstracts: Dentistry
DOI: 10.4172/2161-1122.C1.012
Abstract
Introduction: Implantology has made a huge progress in recent years, not only through the development of implants (design, surface finish, connections) but even more, thanks to CAD/CAM. But how the concept of CAI allows a surgical-prosthetic therapeutic approach different from a so-called "conventional"? Aim: This study was conducted to evaluate the accuracy of computer assisted implantology. Materials & Methods: Coupled the CEREC system to CBCT allows three dimensional acquisition type CBST. Secondly, we have to take an optical impression by using camera with coating by dioxyde titane, consequently a virtual three dimensional model is done. We used CEREC software to plan our prosthetic with superposition data from the CBCT and CEREC. Result & Discussion: CEREC system coupling to CBCT helps to determine the implant site, but also the choice of type of implant, the design and positioning in 3D. The prosthetic project is modeled virtually (digital wax up) and the surgical guide is designed by CAD thus the temporary prosthetic is designed before surgery. The optical impression makes the maximum reduction of dependence materials like less impression materials, less steps, no disinfection and shipping. Errors in the acquisition and processing of radiological images was on average less than 0.5 mm and mistakes when performing the surgical guide were generally around 0.1 to 0.2 mm for the guides made by CAM. Apical deviation of the position of the implant between the virtual planning and actually obtained implant position was ranging between 0.6 mm and 1.2 mm. Of course this method has its limits such as: high cost. Conclusion: The concepts have evolved and today CAI seems to be emerging as a sub discipline through the many contributions and interest it conveys: it could well sign the evolution of a new era.
Biography

Zenati has completed her PhD from Algeria University and Post-doctoral studies from Algeria University School of Medicine. She has done many courses, conferences and communications. She is an Assistant Professor in Prosthodontics and Occlusodontics.

Email: [email protected]

image PDF   |   image HTML
 

Relevant Topics

Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2018-19
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

Agri & Aquaculture Journals

Dr. Krish

[email protected]

+1-702-714-7001Extn: 9040

Biochemistry Journals

Datta A

[email protected]

1-702-714-7001Extn: 9037

Business & Management Journals

Ronald

busines[email protected]

1-702-714-7001Extn: 9042

Chemistry Journals

Gabriel Shaw

[email protected]

1-702-714-7001Extn: 9040

Clinical Journals

Datta A

[email protected]

1-702-714-7001Extn: 9037

Engineering Journals

James Franklin

[email protected]

1-702-714-7001Extn: 9042

Food & Nutrition Journals

Katie Wilson

[email protected]

1-702-714-7001Extn: 9042

General Science

Andrea Jason

[email protected]

1-702-714-7001Extn: 9043

Genetics & Molecular Biology Journals

Anna Melissa

[email protected]

1-702-714-7001Extn: 9006

Immunology & Microbiology Journals

David Gorantl

[email protected]

1-702-714-7001Extn: 9014

Materials Science Journals

Rachle Green

[email protected]

1-702-714-7001Extn: 9039

Nursing & Health Care Journals

Stephanie Skinner

[email protected]

1-702-714-7001Extn: 9039

Medical Journals

Nimmi Anna

[email protected]

1-702-714-7001Extn: 9038

Neuroscience & Psychology Journals

Nathan T

[email protected]

1-702-714-7001Extn: 9041

Pharmaceutical Sciences Journals

Ann Jose

[email protected]

1-702-714-7001Extn: 9007

Social & Political Science Journals

Steve Harry

[email protected]

1-702-714-7001Extn: 9042

 
© 2008- 2018 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
Leave Your Message 24x7