alexa The Scanning Ion Conductance Microscope Is More Than A Microscope
ISSN: 2329-6577

Biological Systems: Open Access
Open Access

OMICS International organises 3000+ Global Conferenceseries Events every year across USA, Europe & Asia with support from 1000 more scientific Societies and Publishes 700+ Open Access Journals which contains over 50000 eminent personalities, reputed scientists as editorial board members.

Open Access Journals gaining more Readers and Citations

700 Journals and 15,000,000 Readers Each Journal is getting 25,000+ Readers

This Readership is 10 times more when compared to other Subscription Journals (Source: Google Analytics)

Share This Page

Additional Info

Loading
Loading Please wait..
 

3rd International Conference on Integrative Biology
August 04-06, 2015 Valencia, Spain

Max Lab
Posters-Accepted Abstracts: Biol Syst Open Access
DOI: 10.4172/2329-6577.S1.003
Abstract
The quest for microscopes that can surmount light diffraction limits hasresulted in Scanning probe microscopes. However many of these are not ideal for living biology. The scanning ion conductance microscope (SICM) bridges the gap between the resolutions of (a)the Atomic Force Microscope (AFM) or the scanning electron microscope, and (b) the functional capabilities of conventional light microscopy. The SICM is a high-resolution (submicron) microscope similar in principle to the AFM. But while morphologically definingmembrane near nanostructure, unlike the AFM, which taps the cell, the SICM is notouch. A nanopipette, on a three-axis piezo-actuator scans the nanopipette over living preparations in physiological solutions. Ion current is measured between the pipette tip and the sample. (The sample stage can also move - with pipettestationary.) Feedback control maintains a given ion current and thus maintains distance between the sample and the pipette (no touch). Recorded XYZ pipette movement generate 3D topographical images of live biological samples. The hollow nanopipette probe provides added modalities’, enabling functional studies.The same pipette and feedback control, precisely targets, and patches, discrete regions of the cell for ion channel recording. The SICM can include fluorescence (pipette stationary, sample moves) facilitating structure-function correlations. Also, as a “mechanical” instrument it can precisely measure local membrane compliance (Young’s Modulus). Moreover, applied pressure through the pipette,targeting selected areas indents the membrane, liberating intracellular calcium by mechanosensitive processes. All this is on living tissue. The SICM as a high resolution multifunctional instrument has significant future potential.
image PDF   |   image HTML
 

Relevant Topics

Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords