The subcutaneous implantable cardioverter-defibrillator - First single-center experience with other cardiac implantable electronic devices


9th Annual Meeting on Arrhythmia and Cardiac Surgery

July 14-15, 2016 Brisbane, Australia

Juergen Kuschyk

Medical Faculty Mannheim of the University of Heidelberg, Germany

Scientific Tracks Abstracts: J Clin Exp Cardiolog

Abstract :

Background: The subcutaneous implantable cardioverter-defibrillator (S-ICD) is an implantable device for anti-arrhythmic therapy with no intravascular leads. Objective: We describe the technical feasibility of combining the S-ICD with other cardiac implantable electronic devices (CIEDs), including pacemakers with trans-venous or epicardial electrodes. We also provide the first experience of combining S-ICD with catheter-based therapies including cardiac contractility modulation (CCM) and vagus nerve stimulation (VNS). Methods: Between 7/2011 and 11/2014 six patients received a CCM device and S-ICD, three patients with a single-chamber pacemaker using either trans-venous or epicardial pacing electrodes received S-ICD, and one patient with an implanted S-ICD received VNS. In all patients intra-operative S-ICD testing, crosstalk tests and postoperative ergometric testing was performed. Results: In all 10 patients device implantations were successfully performed without complications. S-ICD therapy was shown to be technically feasible with concomitant CIED. Mean follow up was nearly 17 months. S-ICD testing and crosstalk testing before and during exercise enabled device programming across a broad range of test conditions and was associated with no subsequent evidence of adverse device interaction. None of the devices required permanent inactivation or removal and no patient received an inappropriate shock. Conclusion: In suitable patients, combining an S-ICD with CCM or pacemaker may provide an acceptable means to reduce the number of trans-vascular leads. S-ICD appeared safe with CCM over an intermediate follow-up period. Additional prospective randomized controlled trials examining S-ICD in conjunction with CIEDs are warranted.

Biography :

Juergen Kuschyk has completed his Medical Degree at the University of Münster, Germany. He is the Director of Device Therapy at the University Medical Center Mannheim, Germany. He is Senior Consultant in Cardiology-Electrophysiology. He has published more than 100 papers in reputed journals and has been serving as an Editorial Board Member of repute. He is international procter for S-ICD and CCM. From 2000-2015, he gave >200 international presentations on device therapy. His main clinical research includes: Device therapy for prevention of sudden cardiac death and chronic heart failure.

Email: juergen.kuschyk@umm.de

Top