alexa A comparison of redox polymer and enzyme co-immobilization on carbon electrodes to provide membrane-less glucose O2 enzymatic fuel cells with improved power output and stability.
Engineering

Engineering

Journal of Biosensors & Bioelectronics

Author(s): Rengaraj S, Kavanagh P, Leech D

Abstract Share this page

Abstract Glassy carbon and graphite electrodes modified with films of enzyme and osmium redox polymer, cross linked with poly (ethylene glycol) diglycidyl ether, were used for elaboration of a glucose/O(2) enzymatic fuel cell. The redox polymers [Os(4,4'-dimethoxy-2,2'-bipyridine)(2)(polyvinylimidazole)(10)Cl](+) and [Os(4,4'-dichloro-2,2'-bipyridine)(2)(polyvinylimidazole)(10)Cl](+) were selected to facilitate transfer of electrons from the glucose oxidase (GOx) active site to the T1 Cu site of multicopper oxygenases of Trametes hirsuta laccase (ThLacc) and Myrothecium verrucaria bilirubin oxidase (MvBOD). Maximum power density at pH 5.5 of 3.5 μW cm(-2) at a cell voltage of 0.35 V was obtained for an assembled membrane-less fuel cell based on ThLacc on glassy carbon as cathode, in the presence of 0.1 M glucose, 37 °C, with lower power observed at pH 7.4 and 4.5. Replacement of the ThLacc cathode with that of MvBOD produced 10 μW cm(-2) at 0.25 V under pseudo-physiological conditions. Replacement of glassy carbon with graphite as base electrode material resulted in increased redox polymer loading, leading to an increase in power output to 43 μW cm(-2) at 0.25 V under similar conditions. Improved stabilization of biofilms was achieved through covalent anchoring of enzyme and redox polymer on graphite electrodes, derivatized via electrochemical reduction of the diazonium cation generated in situ from p-phenylenediamine. Enzymatic fuel cells using this approach retained 70\% power at 24 h, whereas fuel cells prepared without chemical anchoring to graphite retained only 10\% of power over the same interval. Copyright © 2011 Elsevier B.V. All rights reserved. This article was published in Biosens Bioelectron and referenced in Journal of Biosensors & Bioelectronics

Relevant Expert PPTs

Relevant Speaker PPTs

Recommended Conferences

Relevant Topics

Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords