alexa A comprehensive evaluation of perioperative adjuncts during minimally invasive parathyroidectomy: which is most reliable?
Surgery

Surgery

Journal of Surgery

Author(s): Chen H, Mack E, Starling JR

Abstract Share this page

Abstract OBJECTIVE: To determine the utility of several perioperative adjuncts for parathyroid localization during parathyroid surgery, we prospectively compared the accuracy of sestamibi-single photon emission computed tomography (SPECT) scanning, radioguided surgery, and intraoperative parathyroid hormone (ioPTH) testing. SUMMARY AND BACKGROUND DATA: Minimally invasive parathyroidectomy (MIP) is rapidly becoming the procedure of choice in patients with primary hyperparathyroidism (HPT). Several perioperative adjuncts can be used to localize parathyroid adenomas, including sestamibi-SPECT scanning, radioguided surgery, and ioPTH testing. However, the relative value of each of these technologies is unclear. METHODS: Between March 2001 through September 2004, 254 patients with primary HPT underwent parathyroidectomy. All patients had preoperative imaging studies and underwent radioguided surgery with a gamma probe and ioPTH testing. The use of each perioperative adjunct was determined based on the intraoperative findings. RESULTS: The mean age of patients was 61 +/- 1 year. The mean calcium and parathyroid hormone levels were 11.4 +/- 0.1 mg/dL and 136 +/- 6 pg/mL, respectively. Of the 254 patients, 206 (81\%) had a single parathyroid adenoma, 28 (11\%) had double adenomas, 19 (8\%) had hyperplasia, and one had parathyroid cancer. All resected parathyroid glands were hypercellular (mean weight = 895 +/- 86 mg). The cure rate after parathyroidectomy was 98\%. The positive predictive values for sestamibi scanning, radioguided surgery, and ioPTH testing were 81\%, 88\%, and 99.5\%, respectively. CONCLUSIONS: This series is one of the largest to date that prospectively compares the use of sestamibi scanning, radioguided surgery, and ioPTH testing. Of all the perioperative adjuncts used during parathyroid surgery, ioPTH testing has the highest sensitivity, positive predictive value, and accuracy. Thus, the inherent variability of sestamibi scanning and radioguided techniques emphasizes the critical role of ioPTH testing during parathyroid surgery.
This article was published in Ann Surg and referenced in Journal of Surgery

Relevant Expert PPTs

Relevant Speaker PPTs

Recommended Conferences

Relevant Topics

Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

Agri, Food, Aqua and Veterinary Science Journals

Dr. Krish

[email protected]

1-702-714-7001 Extn: 9040

Clinical and Biochemistry Journals

Datta A

[email protected]

1-702-714-7001Extn: 9037

Business & Management Journals

Ronald

[email protected]

1-702-714-7001Extn: 9042

Chemical Engineering and Chemistry Journals

Gabriel Shaw

[email protected]

1-702-714-7001 Extn: 9040

Earth & Environmental Sciences

Katie Wilson

[email protected]

1-702-714-7001Extn: 9042

Engineering Journals

James Franklin

[email protected]

1-702-714-7001Extn: 9042

General Science and Health care Journals

Andrea Jason

[email protected]

1-702-714-7001Extn: 9043

Genetics and Molecular Biology Journals

Anna Melissa

[email protected]

1-702-714-7001 Extn: 9006

Immunology & Microbiology Journals

David Gorantl

[email protected]

1-702-714-7001Extn: 9014

Informatics Journals

Stephanie Skinner

[email protected]

1-702-714-7001Extn: 9039

Material Sciences Journals

Rachle Green

[email protected]

1-702-714-7001Extn: 9039

Mathematics and Physics Journals

Jim Willison

[email protected]

1-702-714-7001 Extn: 9042

Medical Journals

Nimmi Anna

[email protected]

1-702-714-7001 Extn: 9038

Neuroscience & Psychology Journals

Nathan T

[email protected]

1-702-714-7001Extn: 9041

Pharmaceutical Sciences Journals

John Behannon

[email protected]

1-702-714-7001Extn: 9007

Social & Political Science Journals

Steve Harry

[email protected]

1-702-714-7001 Extn: 9042

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords