alexa Analysis of low level radioactive metabolites in biological fluids using high-performance liquid chromatography with microplate scintillation counting: method validation and application.
Chemical Engineering

Chemical Engineering

Journal of Analytical & Bioanalytical Techniques

Author(s): Zhu M, Zhao W, Vazquez N, Mitroka JG

Abstract Share this page

Abstract TopCount, a microplate scintillation counter (MSC), has been recently employed as an off-line liquid radiochromatographic detector for radioactive metabolite profile analysis. The present study was undertaken to validate TopCount for metabolite profiling with respect to sensitivity, accuracy, precision and radioactivity recovery. Matrix effects of various human samples on TopCount performance and capability of MSC for volatile metabolite analysis were also investigated. TopCount had a limit of detection (LOD) of 5 DPM and a limit of quantification (LOQ) of 15 DPM for [(14)C]-labeled compounds at a 10min counting time. It was two-fold more sensitive than a liquid scintillation counter (LSC), and 50-100-fold more sensitive than a radioactivity flow detector (RFD). TopCount had comparable accuracy and precision to RFD, and comparable precision to LSC for determining relative abundance of metabolites. Human liver microsome incubation (up to 1 mL), plasma (up to 1 mL), urine (up to 2 mL) and feces (up to 50mg) had no significant quenching effects on TopCount performance. Benzoic acid, a volatile metabolite, was detected by TopCount, but not by Microbeta counter after microplates were dried under vacuum. Radioactivity recovery in HPLC-MSC analysis was reliably determined using an LSC-based method. Examples of using HPLC-MSC for analysis of low levels of radioactive metabolites are presented, including determination of plasma metabolite profile, in vitro reactive metabolites trapped by [(3)H]glutathione, and metabolite concentrations in an enzyme kinetic experiment. The data from this study strongly suggest that HPLC in combination with TopCount is a viable alternative analytical tool for detection and quantification of low levels of radioactive metabolites in biological fluids. This article was published in J Pharm Biomed Anal and referenced in Journal of Analytical & Bioanalytical Techniques

Relevant Expert PPTs

Relevant Speaker PPTs

Relevant Topics

Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

Agri & Aquaculture Journals

Dr. Krish

[email protected]

1-702-714-7001Extn: 9040

Biochemistry Journals

Datta A

[email protected]

1-702-714-7001Extn: 9037

Business & Management Journals

Ronald

[email protected]

1-702-714-7001Extn: 9042

Chemistry Journals

Gabriel Shaw

[email protected]

1-702-714-7001Extn: 9040

Clinical Journals

Datta A

[email protected]

1-702-714-7001Extn: 9037

Engineering Journals

James Franklin

[email protected]

1-702-714-7001Extn: 9042

Food & Nutrition Journals

Katie Wilson

[email protected]

1-702-714-7001Extn: 9042

General Science

Andrea Jason

[email protected]

1-702-714-7001Extn: 9043

Genetics & Molecular Biology Journals

Anna Melissa

[email protected]

1-702-714-7001Extn: 9006

Immunology & Microbiology Journals

David Gorantl

[email protected]

1-702-714-7001Extn: 9014

Materials Science Journals

Rachle Green

[email protected]

1-702-714-7001Extn: 9039

Nursing & Health Care Journals

Stephanie Skinner

[email protected]

1-702-714-7001Extn: 9039

Medical Journals

Nimmi Anna

[email protected]

1-702-714-7001Extn: 9038

Neuroscience & Psychology Journals

Nathan T

[email protected]

1-702-714-7001Extn: 9041

Pharmaceutical Sciences Journals

Ann Jose

[email protected]

1-702-714-7001Extn: 9007

Social & Political Science Journals

Steve Harry

[email protected]

1-702-714-7001Extn: 9042

 
© 2008- 2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords