alexa Application of comprehensive two-dimensional gas chromatography to drugs analysis in doping control.
Chemical Engineering

Chemical Engineering

Journal of Chromatography & Separation Techniques

Author(s): Kueh AJ, Marriott PJ, Wynne PM, Vine JH

Abstract Share this page

Abstract Comprehensive two-dimensional gas chromatography (GC x GC) now occupies a niche within the GC technology regime. The technique is undeniably unique in the manner in which the experiment is conducted, the way results are presented and the interpretive opportunities offered. For the 1000th volume of this journal it is appropriate to expand upon these features, and review the progress made in GC x GC to date. Firstly, brief general comment is made on multidimensional procedures, and to review key aspects of GC x GC. The use of the targeted multidimensional GC method allows absolute retentions in the second dimension of a GC x GC experiment to be estimated, and also offers a novel way to obtain enhanced response for resolved solutes. Then, to illustrate the utility of the technique, the application of GC x GC to the screening of drugs and their metabolites in biological fluids is described using prolintane metabolites in canine urine as an example, with samples taken at four time intervals after administration. This example illustrates the first application of GC x GC in the field of forensic toxicology, an area traditionally dominated by GC-MS. Most drug compounds were found to be retained on the 0.8-m second column for a greater time than the modulation period (3 s) used for initial analysis, under the conditions described. Hence a 0.4-m D2 BPX50 (50\% phenyl methyl polysilphenylene) column was then used throughout, with most compounds retained less than 4 s. For the standard drug mixture, three overlapping drugs on the first dimension column (BPX5) were subsequently baseline resolved on the BPX50 column. For prolintane administration samples, the parent drug and metabolites could be effectively resolved from background matrix peaks. Likewise a 23-drug spike standard in horse urine blank gave acceptable resolution of the drugs from matrix peaks.
This article was published in J Chromatogr A and referenced in Journal of Chromatography & Separation Techniques

Relevant Expert PPTs

Relevant Speaker PPTs

Recommended Conferences

Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

Agri, Food, Aqua and Veterinary Science Journals

Dr. Krish

[email protected]

1-702-714-7001 Extn: 9040

Clinical and Biochemistry Journals

Datta A

[email protected]

1-702-714-7001Extn: 9037

Business & Management Journals

Ronald

[email protected]

1-702-714-7001Extn: 9042

Chemical Engineering and Chemistry Journals

Gabriel Shaw

[email protected]

1-702-714-7001 Extn: 9040

Earth & Environmental Sciences

Katie Wilson

[email protected]

1-702-714-7001Extn: 9042

Engineering Journals

James Franklin

[email protected]

1-702-714-7001Extn: 9042

General Science and Health care Journals

Andrea Jason

[email protected]

1-702-714-7001Extn: 9043

Genetics and Molecular Biology Journals

Anna Melissa

[email protected]

1-702-714-7001 Extn: 9006

Immunology & Microbiology Journals

David Gorantl

[email protected]

1-702-714-7001Extn: 9014

Informatics Journals

Stephanie Skinner

[email protected]

1-702-714-7001Extn: 9039

Material Sciences Journals

Rachle Green

[email protected]

1-702-714-7001Extn: 9039

Mathematics and Physics Journals

Jim Willison

[email protected]

1-702-714-7001 Extn: 9042

Medical Journals

Nimmi Anna

[email protected]

1-702-714-7001 Extn: 9038

Neuroscience & Psychology Journals

Nathan T

[email protected]

1-702-714-7001Extn: 9041

Pharmaceutical Sciences Journals

John Behannon

[email protected]

1-702-714-7001Extn: 9007

Social & Political Science Journals

Steve Harry

[email protected]

1-702-714-7001 Extn: 9042

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords