alexa Assessment of cardiac output from systemic arterial pressure in humans.
Anesthesiology

Anesthesiology

Journal of Anesthesia & Clinical Research

Author(s): Romano SM, Pistolesi M

Abstract Share this page

Abstract OBJECTIVE: To evaluate the reliability, by comparison with established techniques, of a new method to assess cardiac output, called pressure recording analytical method (PRAM), deriving from the analysis of the arterial pressure profile in the time domain the arterial-pressure-blood flow relationship. DESIGN: Criterion standard. SETTING: Hemodynamics laboratory at an university medical center. PATIENTS: Twenty-two hemodynamically stable cardiac patients scheduled for diagnostic right and left heart catheterization. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Cardiac index was simultaneously estimated by direct-oxygen Fick method, thermodilution, and PRAM applied to pressure signals recorded either invasively from an aortic catheter (PRAMa) or noninvasively at the finger (PRAMf) by photoplethysmography. Cardiac index values obtained by established techniques were significantly correlated with those estimated by PRAM: Fick method vs. PRAMa, r(2) =.88, vs. PRAMf, r(2) =.94; thermodilution vs. PRAMa, r(2) =.77, vs. PRAMf, r(2) =.77. The Bland-Altman analysis showed agreement between the Fick method and PRAM, with all data points comprised within the limits of agreement (+/-2SD) (mean difference +/- SD: -0.012 +/- 0.187 L x min(-1) x m(-2) for PRAMa; 0.024 +/- 0.167 L x min(-1) x m(-2) for PRAMf). Agreement was also found between thermodilution and PRAM, with all but one data point lying within the limits of agreement (mean difference +/- SD: -0.154 +/- 0.348 L x min(-1) x m(-2) for PRAMa; -0.108 +/- 0.348 L x min(-1) x m(-2) for PRAMf). CONCLUSIONS: In the range evaluated (cardiac index from 1.65 to 3.91 L x min(-1) x m(-2) by the Fick method), PRAM provides reliable invasive and noninvasive estimates of cardiac output in hemodynamically stable cardiac patients. PRAM may prove clinically useful for the beat-to-beat monitoring of cardiac output.
This article was published in Crit Care Med and referenced in Journal of Anesthesia & Clinical Research

Relevant Expert PPTs

Relevant Speaker PPTs

Recommended Conferences

Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

Agri, Food, Aqua and Veterinary Science Journals

Dr. Krish

[email protected]

1-702-714-7001 Extn: 9040

Clinical and Biochemistry Journals

Datta A

[email protected]

1-702-714-7001Extn: 9037

Business & Management Journals

Ronald

[email protected]

1-702-714-7001Extn: 9042

Chemical Engineering and Chemistry Journals

Gabriel Shaw

[email protected]

1-702-714-7001 Extn: 9040

Earth & Environmental Sciences

Katie Wilson

[email protected]

1-702-714-7001Extn: 9042

Engineering Journals

James Franklin

[email protected]

1-702-714-7001Extn: 9042

General Science and Health care Journals

Andrea Jason

[email protected]

1-702-714-7001Extn: 9043

Genetics and Molecular Biology Journals

Anna Melissa

[email protected]

1-702-714-7001 Extn: 9006

Immunology & Microbiology Journals

David Gorantl

[email protected]

1-702-714-7001Extn: 9014

Informatics Journals

Stephanie Skinner

[email protected]

1-702-714-7001Extn: 9039

Material Sciences Journals

Rachle Green

[email protected]

1-702-714-7001Extn: 9039

Mathematics and Physics Journals

Jim Willison

[email protected]

1-702-714-7001 Extn: 9042

Medical Journals

Nimmi Anna

[email protected]

1-702-714-7001 Extn: 9038

Neuroscience & Psychology Journals

Nathan T

[email protected]

1-702-714-7001Extn: 9041

Pharmaceutical Sciences Journals

John Behannon

[email protected]

1-702-714-7001Extn: 9007

Social & Political Science Journals

Steve Harry

[email protected]

1-702-714-7001 Extn: 9042

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords