alexa Biomechanical analysis of pinning techniques for pediatric supracondylar humerus fractures.
Surgery

Surgery

Journal of Trauma & Treatment

Author(s): Larson L, Firoozbakhsh K, Passarelli R, Bosch P

Abstract Share this page

Abstract BACKGROUND: Closed reduction and percutaneous pin fixation is the recommended treatment of displaced (Gartland types 2 and 3) supracondylar humerus fractures. The need for a medial pin for maximal stability remains controversial. The purpose of this study was to develop a model of supracondylar humerus fractures simulating medial column comminution and to evaluate the torsional stability of various pin configurations recommended in the current literature. METHODS: Transverse cuts were made in synthetic humeri with a wedge taken from the medial aspect of the proximal fracture fragment in one half of the specimens to simulate medial column comminution. Each fracture was then reduced and fixed with 1 of 4 pin configurations using 0.062 in K-wires. The fixed specimens were then subjected to a torsional load producing internal rotation of the distal fragment. Rotation in degrees and the corresponding torque was recorded for statistical analysis. RESULTS: Specimens with the medial wedge removed demonstrated less torsional stability than their identically fixed counterparts with the intact medial column. In specimens with the intact medial column, the greatest torsional stability was achieved with the 2 lateral divergent and medial cross pin configuration followed by 3 lateral pins, then standard crossed pins with 2 lateral divergent pins demonstrating the least torsional stability. For the medial comminution group the 2 lateral, 1 medial pin construct again had the greatest torsional stability and 2 lateral pins the least. The standard crossed pin and 3 lateral pin constructs were not significantly different in the presence of medial comminution. CONCLUSIONS: In a synthetic humerus model of supracondylar humerus fractures, medial comminution was shown to reduce torsional stability significantly in all pin configurations. There was no statistical difference in torsional stability between 3 lateral pins and standard crossed pins in specimens with medial comminution. This article was published in J Pediatr Orthop and referenced in Journal of Trauma & Treatment

Relevant Expert PPTs

Relevant Speaker PPTs

Recommended Conferences

Relevant Topics

Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

Agri & Aquaculture Journals

Dr. Krish

[email protected]

1-702-714-7001Extn: 9040

Biochemistry Journals

Datta A

[email protected]

1-702-714-7001Extn: 9037

Business & Management Journals

Ronald

[email protected]

1-702-714-7001Extn: 9042

Chemistry Journals

Gabriel Shaw

[email protected]

1-702-714-7001Extn: 9040

Clinical Journals

Datta A

[email protected]

1-702-714-7001Extn: 9037

Engineering Journals

James Franklin

[email protected]

1-702-714-7001Extn: 9042

Food & Nutrition Journals

Katie Wilson

[email protected]

1-702-714-7001Extn: 9042

General Science

Andrea Jason

[email protected]

1-702-714-7001Extn: 9043

Genetics & Molecular Biology Journals

Anna Melissa

[email protected]

1-702-714-7001Extn: 9006

Immunology & Microbiology Journals

David Gorantl

[email protected]

1-702-714-7001Extn: 9014

Materials Science Journals

Rachle Green

[email protected]

1-702-714-7001Extn: 9039

Nursing & Health Care Journals

Stephanie Skinner

[email protected]

1-702-714-7001Extn: 9039

Medical Journals

Nimmi Anna

[email protected]

1-702-714-7001Extn: 9038

Neuroscience & Psychology Journals

Nathan T

[email protected]

1-702-714-7001Extn: 9041

Pharmaceutical Sciences Journals

Ann Jose

[email protected]

1-702-714-7001Extn: 9007

Social & Political Science Journals

Steve Harry

[email protected]

1-702-714-7001Extn: 9042

 
© 2008- 2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords