alexa Capillary electrophoretic analysis of brimonidine in aqueous humor of the eye and blood sera and relation of its levels with intraocular pressure.
Chemical Engineering

Chemical Engineering

Journal of Chromatography & Separation Techniques

Author(s): Tzovolou DN, Lamari F, Mela EK, Gartaganis SP, Karamanos NK

Abstract Share this page

Abstract The aim of this study was the development of a capillary electrophoretic method for the determination of the levels of the selective alpha(2)-adrenergic receptor agonist brimonidine in aqueous humor of the eye and blood sera and their relation to its efficacy in reducing the intraocular pressure (IOP). Analysis of brimonidine was performed by capillary zone electrophoresis using 20 mM borate, pH 9.3, as operating buffer and detection at 255 nm. Brimonidine levels were determined in aqueous humor and blood sera from seven patients admitted for cataract extraction following ocular administration of the ophthalmic Alphagantrade mark solution. Levels of brimonidine and IOP values were recorded for a 24 h period. Alphagantrade mark administration resulted in a significant reduction of IOP, from within 30 min up to 4-5 h, whereafter a stepwise increase was recorded until 24 h, where mean IOP value returned to that before administration. The IOP reduction was related to the levels of brimonidine in aqueous humor, where maximal levels (80-100\%) were obtained within 1-3 h. A 50\% amount of the solution was determined after 4-5 h, whereas it reached the minimum level after 12 h. Serum levels reached maximum within 3-4 h, a 50\% reduction was recorded in 12 h and minimum level in 24 h. It is concluded that brimonidine administration may significantly reduce IOP in patients when its level is maintained >/=50\% of the maximum present in aqueous humor, i.e within a 4-6 h period. Since at this time the level of brimonidine in blood serum has reached maximum value, administration of brimonidine every 6 h may be used to obtain adequate brimonidine levels to maintain a constantly lowered IOP. Copyright 2000 John Wiley & Sons, Ltd. This article was published in Biomed Chromatogr and referenced in Journal of Chromatography & Separation Techniques

Recommended Conferences

Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords