alexa Carrier tests to assess microbicidal activities of chemical disinfectants for use on medical devices and environmental surfaces.
General Science

General Science

Journal of Bioterrorism & Biodefense

Author(s): Springthorpe VS, Sattar SA

Abstract Share this page

Abstract For well over a decade, many deficiencies have been identified in current AOAC methods used to assess the microbicidal activities of chemical disinfectants on medical devices and environmental surfaces. This report discusses the development of quantitative carrier tests (QCT) designed to address these concerns. Decontamination of surfaces with dried inocula is invariably more difficult than when microorganisms are in suspension. For medical device as well as environmental decontamination, microbicides are used on contaminated surfaces, thus making it necessary to evaluate their microbicidal action on representative carrier materials contaminated with a dried challenge microorganism(s). Our approach is a 2-tiered QCT. The first tier (QCT-1) uses relatively ideal conditions to assess performance of the microbicide for screening purposes; the test uses smooth glass surfaces and quantities of disinfectant in excess of those likely to be experienced in the field. The second tier of testing (QCT-2) is more stringent because it uses (1) disks of brushed stainless steel as carriers, (2) only 50 microL of the test formulation on each carrier as compared to 1 mL in QCT-1, and (3) an added soil load to simulate the presence of residual body fluids or accumulated surface dirt. This review also discusses the factors that affect disinfection of medical devices and environmental surfaces in the context of the methodology used to evaluate the potency of microbicides. Specific recommendations for discussion are included, and performance criteria are suggested based on a risk-reduction approach for different classes of disinfectants. The focus is on improving the relevance of the test methodology to actual field use of disinfectants for devices and facilities in health care, and potentially in other settings. It is hoped that this review and its recommendations will initiate needed discussion and resolution of the many issues identified.
This article was published in J AOAC Int and referenced in Journal of Bioterrorism & Biodefense

Relevant Expert PPTs

Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

Agri & Aquaculture Journals

Dr. Krish

[email protected]

1-702-714-7001Extn: 9040

Biochemistry Journals

Datta A

[email protected]

1-702-714-7001Extn: 9037

Business & Management Journals

Ronald

[email protected]

1-702-714-7001Extn: 9042

Chemistry Journals

Gabriel Shaw

[email protected]

1-702-714-7001Extn: 9040

Clinical Journals

Datta A

[email protected]

1-702-714-7001Extn: 9037

Engineering Journals

James Franklin

[email protected]

1-702-714-7001Extn: 9042

Food & Nutrition Journals

Katie Wilson

[email protected]

1-702-714-7001Extn: 9042

General Science

Andrea Jason

[email protected]

1-702-714-7001Extn: 9043

Genetics & Molecular Biology Journals

Anna Melissa

[email protected]

1-702-714-7001Extn: 9006

Immunology & Microbiology Journals

David Gorantl

[email protected]

1-702-714-7001Extn: 9014

Materials Science Journals

Rachle Green

[email protected]

1-702-714-7001Extn: 9039

Nursing & Health Care Journals

Stephanie Skinner

[email protected]

1-702-714-7001Extn: 9039

Medical Journals

Nimmi Anna

[email protected]

1-702-714-7001Extn: 9038

Neuroscience & Psychology Journals

Nathan T

[email protected]

1-702-714-7001Extn: 9041

Pharmaceutical Sciences Journals

Ann Jose

[email protected]

1-702-714-7001Extn: 9007

Social & Political Science Journals

Steve Harry

[email protected]

1-702-714-7001Extn: 9042

 
© 2008- 2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords