alexa Cerebral oxygen saturation measured by near-infrared spectroscopy and jugular venous bulb oxygen saturation during arthroscopic shoulder surgery in beach chair position under sevoflurane-nitrous oxide or propofol-remifentanil anesthesia.
Anesthesiology

Anesthesiology

Journal of Anesthesia & Clinical Research

Author(s): Hyejin Jeong, Seongtae Jeong, Kyung Yoo

Abstract Share this page

BACKGROUND: We examined the effects of different anesthetics on cerebral oxygenation and systemic hemodynamics in patients undergoing surgery in beach chair position (BCP). Jugular venous bulb oxygen saturation (SjvO2) and regional cerebral tissue oxygen saturation (SctO2) were determined while patients were placed from the supine to BCP. Whether SctO2 and SjvO2 are interchangeable in assessing the cerebral oxygenation was also examined. METHODS: Forty patients undergoing shoulder surgery in BCP were randomly assigned to receive sevoflurane-nitrous oxide (S/N) or propofol-remifentanil (P/R) anesthesia. Four patients taking angiotensin II receptor antagonists were excluded post hoc. Mean arterial pressure and heart rate, as well as SjvO2 and SctO2, were measured before (postinduction baseline in supine position) and after BCP. RESULTS: Mean arterial pressure decreased by BCP in both groups. It was, however, significantly higher in S/N (n = 19) than in P/R group (n = 17) at 7 to 8 min after the positioning. SjvO2 also significantly decreased after BCP in both groups, the magnitude of which was lower in S/N than in P/R group (11 ± 10% vs. 23 ± 9%, P = 0.0006). The incidences of SjvO2 <50% and mean arterial pressure less than 50 mmHg were lower in S/N group, but SctO2and the incidence of cerebral desaturation (more than 20% decrease from baseline) did not significantly differ between the groups. SctO2 and SjvO2 were only weakly correlated (β = 0.218, r2 = 0.133). Bland-Altman analysis showed a mean difference of -7.2% with 95% limit of agreement between -38.2% and 23.8%. CONCLUSIONS: The margin of safety against impaired cerebral oxygenation is greater and SjvO2 is more preserved with S/N than with P/R anesthesia. SctO2 may not be reliable in detecting a low SjvO2 during the surgery in BCP.

This article was published in Anesthesiology. and referenced in Journal of Anesthesia & Clinical Research

Relevant Expert PPTs

Relevant Speaker PPTs

Recommended Conferences

Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

Agri, Food, Aqua and Veterinary Science Journals

Dr. Krish

[email protected]

1-702-714-7001 Extn: 9040

Clinical and Biochemistry Journals

Datta A

[email protected]

1-702-714-7001Extn: 9037

Business & Management Journals

Ronald

[email protected]

1-702-714-7001Extn: 9042

Chemical Engineering and Chemistry Journals

Gabriel Shaw

[email protected]

1-702-714-7001 Extn: 9040

Earth & Environmental Sciences

Katie Wilson

[email protected]

1-702-714-7001Extn: 9042

Engineering Journals

James Franklin

[email protected]

1-702-714-7001Extn: 9042

General Science and Health care Journals

Andrea Jason

[email protected]

1-702-714-7001Extn: 9043

Genetics and Molecular Biology Journals

Anna Melissa

[email protected]

1-702-714-7001 Extn: 9006

Immunology & Microbiology Journals

David Gorantl

[email protected]

1-702-714-7001Extn: 9014

Informatics Journals

Stephanie Skinner

[email protected]

1-702-714-7001Extn: 9039

Material Sciences Journals

Rachle Green

[email protected]

1-702-714-7001Extn: 9039

Mathematics and Physics Journals

Jim Willison

[email protected]

1-702-714-7001 Extn: 9042

Medical Journals

Nimmi Anna

[email protected]

1-702-714-7001 Extn: 9038

Neuroscience & Psychology Journals

Nathan T

[email protected]

1-702-714-7001Extn: 9041

Pharmaceutical Sciences Journals

John Behannon

[email protected]

1-702-714-7001Extn: 9007

Social & Political Science Journals

Steve Harry

[email protected]

1-702-714-7001 Extn: 9042

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords