alexa Comparison of accuracy of optic nerve ultrasound for the detection of intracranial hypertension in the setting of acutely fluctuating vs stable intracranial pressure: post-hoc analysis of data from a prospective, blinded single center study.
Medicine

Medicine

Emergency Medicine: Open Access

Author(s): Rajajee V, Fletcher JJ, Rochlen LR, Jacobs TL

Abstract Share this page

Abstract INTRODUCTION: Optic nerve sheath diameter (ONSD) measurement with bedside ultrasound has been shown in many studies to accurately detect high intracranial pressure (ICP). The accuracy of point-in-time ONSD measurement in the presence of ongoing fluctuation of ICP between high and normal is not known. Recent laboratory investigation suggests that reversal of optic nerve sheath distension may be impaired following bouts of intracranial hypertension. Our objective was to compare the accuracy of ONSD measurement in the setting of fluctuating versus stable ICP. METHODS: This was a retrospective analysis of data from prospective study comparing ONSD to invasive ICP. Patients with invasive ICP monitors in the ICU underwent ONSD measurement with simultaneous blinded recording of ICP from the invasive monitor. Three measurements were made in each eye. Significant acute ICP fluctuation (SAIF) was defined in two different ways; as the presence of ICP both above and below 20 mmHg within a cluster of six measurements (Definition 1) and as a magnitude of fluctuation >10 mmHg within the cluster (Definition 2). The accuracy of point-in-time ONSD measurements for the detection of concurrent ICP >20 mmHg within clusters fulfilling a specific definition of SAIF was compared to the accuracy of ONSD measurements within clusters not fulfilling the particular definition by comparison of independent receiver operating characteristic (ROC) curves. RESULTS: A total of 613 concurrent ONSD-ICP measurements in 109 clusters were made in 73 patients. Twenty-three (21\%) clusters fulfilled SAIF Definition 1 and 17 (16\%) SAIF Definition 2. For Definition 1, the difference in the area under the curve (AUC) of ROC curves for groups with and without fluctuation was 0.10 (P = 0.0001). There was a fall in the specificity from 98\% (95\% CI 96 to 99\%) to 74\% (63 to 83\%) and in the positive predictive value from 89\% (80 to 95\%) to 76\% (66 to 84\%) with fluctuation. For Definition 2, also, there was a significant difference between the AUC of ROC curves of groups with fluctuation-magnitude >10 mmHg and those with fluctuation-magnitude 5 to 10 mmHg (0.06, P = 0.04) as well as <5 mmHg (0.07, P = 0.01). CONCLUSIONS: Specificity and PPV of ONSD for ICP >20 mmHg are substantially decreased in patients demonstrating acute fluctuation of ICP between high and normal. This may be because of delayed reversal of nerve sheath distension.
This article was published in Crit Care and referenced in Emergency Medicine: Open Access

Relevant Expert PPTs

Relevant Speaker PPTs

Relevant Topics

Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

Agri, Food, Aqua and Veterinary Science Journals

Dr. Krish

[email protected]

1-702-714-7001 Extn: 9040

Clinical and Biochemistry Journals

Datta A

[email protected]

1-702-714-7001Extn: 9037

Business & Management Journals

Ronald

[email protected]

1-702-714-7001Extn: 9042

Chemical Engineering and Chemistry Journals

Gabriel Shaw

[email protected]

1-702-714-7001 Extn: 9040

Earth & Environmental Sciences

Katie Wilson

[email protected]

1-702-714-7001Extn: 9042

Engineering Journals

James Franklin

[email protected]

1-702-714-7001Extn: 9042

General Science and Health care Journals

Andrea Jason

[email protected]

1-702-714-7001Extn: 9043

Genetics and Molecular Biology Journals

Anna Melissa

[email protected]

1-702-714-7001 Extn: 9006

Immunology & Microbiology Journals

David Gorantl

[email protected]

1-702-714-7001Extn: 9014

Informatics Journals

Stephanie Skinner

[email protected]

1-702-714-7001Extn: 9039

Material Sciences Journals

Rachle Green

[email protected]

1-702-714-7001Extn: 9039

Mathematics and Physics Journals

Jim Willison

[email protected]

1-702-714-7001 Extn: 9042

Medical Journals

Nimmi Anna

[email protected]

1-702-714-7001 Extn: 9038

Neuroscience & Psychology Journals

Nathan T

[email protected]

1-702-714-7001Extn: 9041

Pharmaceutical Sciences Journals

John Behannon

[email protected]

1-702-714-7001Extn: 9007

Social & Political Science Journals

Steve Harry

[email protected]

1-702-714-7001 Extn: 9042

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords