Abstract PURPOSE: Implant success, peri-implant conditions, and prosthodontic maintenance requirements were evaluated and compared for mandibular overdentures supported by two implants and retained with ball or resilient telescopic crown attachments during a 5-year period. MATERIALS AND METHODS: Twenty-five patients with an edentulous mandible each received two root-form dental implants in the mandibular interforaminal (canine) region. The type of denture attachment was chosen randomly; 13 patients received ball attachments and 12 patients received resilient telescopic crowns. Implant success and peri-implant conditions (bone resorption, pocket depth, Plaque Index, Gingival Index, Bleeding Index) as well as prosthodontic maintenance and patient satisfaction were evaluated annually during a 5-year follow-up period and compared with respect to the two retention modalities used. RESULTS: Implant success, peri-implant conditions, and subjective patient satisfaction scores did not differ between the two retention modalities used. However, during the 5-year observation period, significantly more postinsertion complications/interventions for maintenance purposes were registered in the ball group (87 interventions, 61.1\%) than in the telescopic crown group (53 interventions, 37.9\%; P < .01). Differences in prosthodontic maintenance efforts were most significant in the second and third years (P < .05) of the follow-up period but were similar at the end of the study for both anchorage systems. CONCLUSION: Both ball attachments and resilient telescopic crowns on isolated implants in the atrophic mandible are viable treatment options for implant-supported overdentures. No implant losses, good peri-implant conditions, and general patient satisfaction were noted. Although the frequency of technical complications was initially higher with ball attachments than with resilient telescopic crowns over a 5-year period, similar frequencies of maintenance efforts may be anticipated for both retention modalities.
This article was published in Int J Oral Maxillofac Implants and referenced in Dentistry

Relevant Expert PPTs

Recommended Conferences

Relevant Topics

Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

Agri, Food, Aqua and Veterinary Science Journals

Dr. Krish

[email protected]

1-702-714-7001 Extn: 9040

Clinical and Biochemistry Journals

Datta A

[email protected]

1-702-714-7001Extn: 9037

Business & Management Journals

Ronald

[email protected]

1-702-714-7001Extn: 9042

Chemical Engineering and Chemistry Journals

Gabriel Shaw

[email protected]

1-702-714-7001 Extn: 9040

Earth & Environmental Sciences

Katie Wilson

[email protected]

1-702-714-7001Extn: 9042

Engineering Journals

James Franklin

[email protected]

1-702-714-7001Extn: 9042

General Science and Health care Journals

Andrea Jason

[email protected]

1-702-714-7001Extn: 9043

Genetics and Molecular Biology Journals

Anna Melissa

[email protected]

1-702-714-7001 Extn: 9006

Immunology & Microbiology Journals

David Gorantl

[email protected]

1-702-714-7001Extn: 9014

Informatics Journals

Stephanie Skinner

[email protected]

1-702-714-7001Extn: 9039

Material Sciences Journals

Rachle Green

[email protected]

1-702-714-7001Extn: 9039

Mathematics and Physics Journals

Jim Willison

[email protected]

1-702-714-7001 Extn: 9042

Medical Journals

Nimmi Anna

[email protected]

1-702-714-7001 Extn: 9038

Neuroscience & Psychology Journals

Nathan T

[email protected]

1-702-714-7001Extn: 9041

Pharmaceutical Sciences Journals

John Behannon

[email protected]

1-702-714-7001Extn: 9007

Social & Political Science Journals

Steve Harry

[email protected]

1-702-714-7001 Extn: 9042

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords