alexa Comparison of DATs using traditional tube agglutination to gel column and affinity column procedures.
Haematology

Haematology

Journal of Blood Disorders & Transfusion

Author(s): Dittmar K, Procter JL, Cipolone K, Njoroge JM, Miller J, , Dittmar K, Procter JL, Cipolone K, Njoroge JM, Miller J,

Abstract Share this page

Abstract BACKGROUND: Detection of immunoglobulin or complement bound to RBCs by using the DAT is valuable in the diagnosis of immune-mediated hemolytic anemia. Traditionally, the DAT has been performed by tube agglutination using anti-IgG or anti-C3d. The purpose of this study was to compare the tube agglutination DAT to gel microcolumn, affinity microcolumn, and flow cytometric DATs on RBCs coated in vitro and on patient RBC samples. STUDY DESIGN AND METHODS: RBCs from 84 patients were assessed by tube agglutination DAT, one gel microcolumn DAT, and two affinity microcolumn DATs. One affinity microcolumn assay was unmodified and one was modified by the addition of polyspecific antiglobulin or anti-IgG as a secondary antibody. RBCs from 15 of the 84 patients underwent analysis by flow cytometry with fluorescence-labeled anti-IgG. The assays were also compared by using D+ RBCs sensitized with serially adjusted concentrations of anti-D. RESULTS: Both tube agglutination and gel microcolumn DATs were positive in 49 patient samples; both assays were negative in 20 samples, and the results were discordant in 15. Gel microcolumn DATs were more likely than were tube agglutination DATs to detect IgG on RBCs. Affinity microcolumn DATs were less likely than gel microcolumn or tube agglutination DATs to detect IgG on RBCs. Flow cytometry results were the same as gel microcolumn results in 12 of 15 patient samples and the same as tube agglutination results in 13 of 15. Tube agglutination and both affinity microcolumn assays reacted with RBCs coated with anti-D that was diluted 1-in-100. The gel microcolumn and flow cytometry assays reacted with RBCs coated with anti-D diluted 1-in-400. There was no correlation between tube agglutination and gel microcolumn DATs in detecting bound C3d. CONCLUSION: Detection of IgG bound to RBCs was not consistent with the methods described. Gel microcolumn DATs were more sensitive than tube agglutination and affinity microcolumn DATs. Given the varied results of these assays, reference laboratories should not rely on a single method for DATs. More comprehensive testing should be performed when the tube agglutination DAT is negative in a patient with suspected immune-mediated hemolytic anemia. Further comparisons are necessary to determine the proficiency of flow cytometric assays.
This article was published in Transfusion and referenced in Journal of Blood Disorders & Transfusion

Relevant Expert PPTs

Relevant Speaker PPTs

Recommended Conferences

Relevant Topics

Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

Agri, Food, Aqua and Veterinary Science Journals

Dr. Krish

[email protected]

1-702-714-7001 Extn: 9040

Clinical and Biochemistry Journals

Datta A

[email protected]

1-702-714-7001Extn: 9037

Business & Management Journals

Ronald

[email protected]

1-702-714-7001Extn: 9042

Chemical Engineering and Chemistry Journals

Gabriel Shaw

[email protected]

1-702-714-7001 Extn: 9040

Earth & Environmental Sciences

Katie Wilson

[email protected]

1-702-714-7001Extn: 9042

Engineering Journals

James Franklin

[email protected]

1-702-714-7001Extn: 9042

General Science and Health care Journals

Andrea Jason

[email protected]

1-702-714-7001Extn: 9043

Genetics and Molecular Biology Journals

Anna Melissa

[email protected]

1-702-714-7001 Extn: 9006

Immunology & Microbiology Journals

David Gorantl

[email protected]

1-702-714-7001Extn: 9014

Informatics Journals

Stephanie Skinner

[email protected]

1-702-714-7001Extn: 9039

Material Sciences Journals

Rachle Green

[email protected]

1-702-714-7001Extn: 9039

Mathematics and Physics Journals

Jim Willison

[email protected]

1-702-714-7001 Extn: 9042

Medical Journals

Nimmi Anna

[email protected]

1-702-714-7001 Extn: 9038

Neuroscience & Psychology Journals

Nathan T

[email protected]

1-702-714-7001Extn: 9041

Pharmaceutical Sciences Journals

John Behannon

[email protected]

1-702-714-7001Extn: 9007

Social & Political Science Journals

Steve Harry

[email protected]

1-702-714-7001 Extn: 9042

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords