alexa Comparison of haemoglobin measurement methods in the operating theatre.
Haematology

Haematology

Journal of Blood Disorders & Transfusion

Author(s): Giraud B, Frasca D, Debaene B, Mimoz O, Giraud B, Frasca D, Debaene B, Mimoz O

Abstract Share this page

Abstract BACKGROUND: Various methods of haemoglobin (Hb) measurement are available to guide transfusion including several methods that allow for measurement at the bedside. This study directly compared their absolute and trend accuracy compared with values from the central lab (reference method). METHODS: Adult patients undergoing surgery with expected blood loss wore a rainbow ReSposable sensor connected to a Radical-7 Pulse CO-Oximeter (SpHb). Arterial samples were analysed with a haematology analyser (HbLab), a satellite CO-Oximeter (HbSat), and a point-of-care haemoglobinometer (HemoCue; HcueArt). Concomitantly, ear capillary blood was tested using the same haemoglobinometer (HcueCap). Absolute accuracy and the clinical significance of error were assessed with Bland-Altman plots and three-zone error grids. Trend analysis was performed using a modified polar plot, testing both directionality and magnitude of Hb changes compared with the reference. RESULTS: Two hundred and nineteen measurements from 53 patients with HbLab ranging between 6.8 and 16.3 g dl(-1) (4.2 and 10.1 mmol litre(-1)) were recorded. Compared with the reference method, bias (precision) was 0.2 (0.2) g dl(-1) [0.1 (0.1) mmol litre(-1)] for HcueArt, 0.8 (0.3) g dl(-1) [0.5 (0.2) mmol litre(-1)] for HbSat, 0.5 (0.5) g dl(-1) [0.3 (0.3) mmol litre(-1)] for HcueCap and 1.0 (1.2) g dl(-1) [0.6 (0.7) mmol litre(-1)] for SpHb. None of the devices tested would have led to unnecessary or delayed transfusion according to 2006 ASA transfusion criteria. Trend accuracy was better for HcueArt and HbSat than for HcueCap and SpHb. CONCLUSION: Bedside Hb measurement methods differ in their agreement to a laboratory haematology analyser but none would have led to transfusion errors. Trial Registry Number RCB 2009-AO1144-53. This article was published in Br J Anaesth and referenced in Journal of Blood Disorders & Transfusion

Relevant Expert PPTs

Relevant Speaker PPTs

Recommended Conferences

Relevant Topics

Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords