alexa Compatibility of machined Ce-TZP Al2O3 nanocomposite and a veneering ceramic.
General Science

General Science

Journal of Biotechnology & Biomaterials

Author(s): Fischer J, Stawarczyk B

Abstract Share this page

Abstract OBJECTIVES: Due to its high fracture toughness ceria-stabilized ZrO(2)/Al(2)O(3) nanocomposite (Ce-TZP/A) could be superior to Y-TZP in clinical use. However, the compatibility to veneering ceramics is not yet investigated and therefore subject of this study. METHODS: Fracture strength and crazing resistance of veneered Ce-TZP/A frameworks (Nanozir, Matsushita Electric Works) were investigated in comparison to sintered and hipped Y-TZP (Hint-ELs). Frameworks were machined (HiCut, Hint-ELs), sintered where applicable (hiTherm, Hint-ELs), and veneered in a standardized procedure (Cerabien ZR, Noritake). Fracture strength of the crowns was assessed in a shear test (n=10). Biaxial flexural strength of the core materials was measured according to ISO 6872 (n=10). To assess the thermal compatibility between framework and veneer the coefficient of thermal expansion (CTE) of all materials was determined (n=3) and a crazing test carried out (n=12). RESULTS: Fracture strength was equal for crowns with Ce-TZP/A (866.6+/-132.1N) and sintered Y-TZP (904.5+/-168.2N), while crowns with hipped Y-TZP were significantly stronger (1380.6+/-253.2N) (Student's t-test, p<0.05). These values correlated with the biaxial flexural strength of the three core materials (Ce-TZP/A: 1238.0+/-200.0MPa, sintered Y-TZP: 1181.8+/-232.5MPa and hipped Y-TZP: 1521.8+/-163.8MPa). Failure of both hipped and sintered Y-TZP crowns occurred by chipping of the veneer or total fracture, while the Ce-TZP/A crowns predominantly failed by chipping of the veneer. In the crazing test both sintered and hipped Y-TZP performed slightly better than Ce-TZP/A. CTE's were as follows: Ce-TZP/A: 10.3microm/mK, sintered Y-TZP: 10.7microm/mK, hipped Y-TZP: 10.9microm/mK, and Cerabien ZR: 9.9microm/mK. SIGNIFICANCE: The CTE of the veneering ceramic has to be adjusted to Ce-TZP/A frameworks. This article was published in Dent Mater and referenced in Journal of Biotechnology & Biomaterials

Relevant Expert PPTs

Relevant Speaker PPTs

Recommended Conferences

Relevant Topics

Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords